• 제목/요약/키워드: Pressure Control System

검색결과 2,321건 처리시간 0.031초

압전 작동기로 구동 되는 공압 밸브의 압력제어 (Pressure Control of a Piezoactuator-Driven Pneumatic Valve System)

  • 조명수;유중규;최승복
    • 대한기계학회논문집A
    • /
    • 제26권2호
    • /
    • pp.399-405
    • /
    • 2002
  • This paper proposes a new type of piezoactuator-driven valve system. The piezoceramic actuator bonded to both sides of a flexible beam surface makes a movement required to control the pressure at the flapper-nozzle of a pneumatic valve system. After establishing a dynamic model, an appropriate size of the valve system is designed and manufactured. Subsequently, a robust H$_{\infty}$ control algorithm is formulated in order to achieve accurate tracking control of the desired pressure. The controller is experimentally realized and control performance for the sinusoidal pressure trajectory is presented in time domain. The control bandwidth of the valve system, which directly represents the fastness, is also evaluated in the frequency domain.

제어밸브의 유량특성에 따른 에어스프링의 성능 변화 (Effect of Control Valve Flow Rates Characteristics on the Performance of an Air Spring)

  • 한승훈;장지성;지상원
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권3호
    • /
    • pp.8-14
    • /
    • 2016
  • This study describes the effect of the critical pressure ratio of a control valve on the performance of an air spring system composed of an air spring, auxiliary chamber, control valve and mass in order to suggest a more efficient design for an air spring system. The critical pressure ratio of the control valve is assumed to have a fixed value, but the critical pressure ratio of the control valve is known to have various values between 0.05 and 0.6, and the effect of the variation of the critical pressure ratio on the performance of the air spring system has not yet been reported. The analysis derives nonlinear and linear governing equations of the air spring system, including the critical pressure ratio of the control valve. This simulation study is presented to show that the impedance and transmissibility characteristics of the air spring system change due to variations in the critical pressure ratio of the control valve as well as its sonic conductance. As a result, the critical pressure ratio of the control valve should be maintained as large as possible to improve the vibration isolation characteristics of the air spring system.

차량 자세제어 시스템의 비례압력제어밸브 해석모델 개발 및 최적화 설계 (Optimization Design and Development of the Proportional Pressure Control Valve Analysis Model of Active Body Control)

  • 김동명;장주섭;손태관
    • 한국자동차공학회논문집
    • /
    • 제22권7호
    • /
    • pp.127-134
    • /
    • 2014
  • Active body control system is an important system for determining the driving stability and ride comfort of the vehicle. Active body control system is composed of a cylinder unit power supply unit, and control valve unit. Control valve is a proportional pressure control valve, the dynamic characteristics of the valve affects the performance of the active body control system. We have developed an analytical model, we analyzed the design parameters of the proportional pressure control valve. Further, by knowing the design parameters effect on the system and to optimize the design parameters, and improved performance of the dynamic properties.

압전 작동기로 구동되는 공압 밸브의 압력제어 (Pressure Control of a Piezoactuator-Driven Pneumatic Valve System)

  • 조명수;유중규;최승복
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.554-558
    • /
    • 2000
  • This paper proposes a new type of piezoactuator-driven valve system. The piezoceramic actuator bonded to both sides of a flexible beam surface makes a movement required to control the pressure at the flapper-nozzle of a pneumatic system. After establishing a dynamic model, an appropriate size of the valve system is designed and manufactured. Subsequently, a sliding mode controller which is known to be robust to uncertainties such as disturbance is formulated in order to achieve accurate regulating and tracking control of the desired pressure. The controller is experimentally realized and control performances for various pressure trajectories are presented in time domain. The control bandwidth of the valve system which directly represents the fastness is also evaluated in the frequency domain.

  • PDF

EPPRV 적용 굴착기 파일롯 시스템 압력 피드백 제어기 설계 (Design of a Pressure Feedback Controller for Hydraulic Excavator Pilot System with EPPRVs)

  • 유승진;박철규;유승한
    • 드라이브 ㆍ 컨트롤
    • /
    • 제21권3호
    • /
    • pp.9-19
    • /
    • 2024
  • Many modern hydraulic excavators now use EPPRVs (Electronic Proportional Pressure Reducing Valves) in their pilot systems to control the spool displacement of the main hydraulic system. However, the performance of these systems is often limited by factors such as magnetic hysteresis, mechanical wear, and transient responses influenced by operating conditions and component installation. This paper presents a pressure feedback controller for excavator pilot systems that utilize EPPRVs. This controller significantly reduces steady-state pressure control errors and mitigates the hysteresis effects commonly seen in traditional open-loop systems. To achieve this, we integrated EPPRVs with the main hydraulic valve and injected a chirp signal into the solenoid current. By doing so, we were able to measure the frequency response of the pilot system across different operating pressures and estimate the system dynamics model. Using these models, we designed a set of PI pressure feedback controllers that are guaranteed to be stable. These controllers were then integrated with a gain scheduler based on a lookup table. Experimental results demonstrate that when the developed pressure feedback controller is incorporated into the conventional open-loop controller, it effectively reduces steady-state pressure control errors and mitigates hysteresis.

개폐식 3방향 전자밸브의 펄스폭 변조 구동에 의한 압력제어 특성에 관한 연구 (A Study on the Pressure Control Characteristics of ON/OFF 3-way Solenoid Valve Driven by PWM Signal)

  • 정헌술
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.485-501
    • /
    • 1997
  • Pressure control is possible driving a simple ON/OFF 3-way valve of hydraulic servo system by pulse width modulation signal. But the pressure varies according to the duty ratio and carrier frequency and repeated on-off action induces pressure fluctuation. So equations for mean pressure and ripple amplitude are theoretically derived as a function of on/off time, the system parameters which decide the pressure characteristics are arranged and they are verified by experimental study. As the result selection criteria for the major design parameters are established and the basic strategy to suppress the unnecessary fluctuation can be provided for a hydraulic pressure control system using these type of valves.

피에조밸브를 적용한 전자유압브레이크의 압력제어 (Advanced Pressure Control of Piezoelectric Valve on Electro-hydraulic Braking)

  • 독고종훈;박귀태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1576-1577
    • /
    • 2007
  • As a intelligent valve piezoelectric valve is to applied to various fields of application. Piezoelectric valves have fast response time and good linearity for pressure control but its hysteresis displacement by its stack actuator influences on pressure control in electro-hydraulic braking. Solenoid valves are traditional element to control hydraulic pressure but this paper proposes piezoelectric valve for brake pressure control with hysteresis compensation.

  • PDF

압전 작동기로 구동 되는 공압 밸브의 $H_{\infty}$ 압력제어 ([ $H_{\infty}$ ] Pressure Control of Pneumatic Valve Driven by Piezoactuators)

  • 유중규;조명수;최승복
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.673-678
    • /
    • 2001
  • This paper proposes a new type of piezoactuator-driven valve system. The piezoceramic actuator bonded to both sides of a flexible beam surface makes a movement required to control the pressure at the flapper-nozzle of a pneumatic valve system. After establishing a dynamic model, an appropriate size of the valve system is designed and manufactured. Subsequently, a robust $H_{\infty}$ control algorithm is formulated in order to achieve accurate tracking control of the desired pressure. The controller is experimentally realized and control performance for the sinusoidal pressure trajectory is presented in time domain. The control bandwidth of the valve system, which directly represents the fastness, is also evaluated in the frequency domain.

  • PDF

터빈 밸브시험 중 충동실 압력제어에 의한 발전기 출력변동 최소화 (The Minimization of Generator Output Variations by Impulse Chamber Pressure Control during Turbine Valve Test)

  • 최인규;김종안;박두용;우주희;신재호
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.152-159
    • /
    • 2010
  • This paper describes the actual application of a feedback control loop as a means for minimizing turbine impulse chamber pressure variation during the turbine steam valve tests at a 1,000 MW nuclear power plant. The chamber pressure control loop was implemented in the new digital control system which was installed as a replacement for the old analog type control system. There has been about 40MW of the generator output change during the steam valve tests, especially the high pressure governing valve tests, because the old control system had not the impulse chamber pressure control so the operators had to compensate steam flow drop manually. The process of each valve test consists of a closing process and an reopening process and the operators can make sure that the valves are in their sound conditions by checking the valves movement. The control algorithm described in this paper contributed to keep the change in megawatt only to 6MW during the steam valve tests. Thereby, the disturbance to reactor control was reduced, and the overall plant control system's stability was greatly improved as well.

통합 제연시스템의 컨트롤러 개발에 관한 연구 (A Study on the Controller of Integration Smoke Control System)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제20권1호
    • /
    • pp.77-82
    • /
    • 2006
  • 본 연구에서는 온도가 보상된 압력을 제연구역의 기준압력으로 설정하기 위한 공학적인 메커니즘과 보상방법을 정립하였고, 통합 제연시스템의 컨트롤러의 개발을 위한 프로세스, 알고리즘 확립과 엔지니어링 데이터의 구축으로 신뢰성이 확보된 통합 제연시스템의 컨트롤러를 개발하였다. 컨트롤러를 개발함으로서 비제연구역의 압력측정을 위해서 별도로 설치되는 압력측정관을 생략할 수 있어 제작단가와 설치비용 및 작업공수를 줄일 수 있고, 층별 제연구역의 차압측정을 위한 비제연구역의 압력측정포트를 시스템에 일체화함으로서 차압의 정밀도를 향상시킬 수 있다. 기존의 개별제어 방식에서 통합 제연시스템의 컨트롤러로부터 중앙집중식 통합관리를 함으로서 보다 정확하고 신뢰성 있는 차압을 얻을 수 있으며, 제연시스템에 유연성을 부과시킬 수 있을 것으로 본다. 또한 통합 제연시스템의 기틀을 마련하고 제연의 유연성을 주며 방재성능을 향상시킬 것으로 본다.