• Title/Summary/Keyword: Pressure Control Device

검색결과 362건 처리시간 0.033초

햅틱 장치를 이용한 균형 훈련 시스템 및 효용성 검증 (A Balance Training System using a Haptic Device and Its Evaluations)

  • 윤정원;라힐 아프잘;표상훈;오민균
    • 제어로봇시스템학회논문지
    • /
    • 제20권9호
    • /
    • pp.971-976
    • /
    • 2014
  • Haptic device can be a useful rehabilitation tool in balance training. The proposed system is composed of a body-wear smartphone, Phantom Omni(R) device, and its control PC system. Ten young healthy subjects performed balance tasks with different postures during 30 seconds with their eyes closed. An Android program on the smartphone transferred mediolateral (ML) and anteroposterior (AP) tilt angles to the PC system, which can generate haptic command through haptic device. Statistical data analysis was performed using MATLAB(R). COP (Center of Pressure) related indexes were measured to see reduction in body sway. ANOVA showed that haptic device significantly reduced body sway. Intuitive balance guidance could be generated using an economical and small-sized commercial haptic device, making the system efficient.

압력 인가 장치의 품질관리를 위한 변위 수용이 가능한 압력 측정용 지그의 유효성 평가 (Effectiveness Evaluation of Displacement Accommodatable Pressure Measuring Jig for Quality Assessment of Pressure Application Device)

  • 문창수;전성철;노시철
    • 융합신호처리학회논문지
    • /
    • 제21권2호
    • /
    • pp.61-66
    • /
    • 2020
  • 최근 치과 시술을 위한 국소마취 시 시술자의 피로감을 줄이고 수동 마취기의 단점을 보완한 다양한 전동형 마취액 주입기가 개발되어 임상에서 사용되고 있다. 이러한 전동형 마취액 주입기기에서는 약물 주입을 위한 압력을 정확하고 일정하게 전달하는 것이 매우 중요한 성능 요소이다. 이러한 전달 압력의 정확성을 평가하기 위하여 로드셀을 이용한 소형의 압력계가 많이 사용되는데, 로드셀 내부의 탄성체가 충분한 변위를 수용할 수 없는 경우가 있어 압력 성능 평가 시 오차를 발생시킬 수도 있다. 이에 본 연구에서는 로드셀 방식의 압력측정기를 이용하여 압력 제어형 압력 인가 장치의 성능을 평가할 때 사용 가능한 비교적 큰 변위 수용이 가능한 실리콘-크롬강(Si-Cr강) 스프링 지그를 제안하였으며 유효성을 평가하였다. 제안된 스프링 지그의 압력 전달률과 상용의 치과용 마취액 주입장치를 이용한 반복 측정 결과, 스프링 지그 사용 시 보다 안정적인 결과를 얻을 수 있었으며, 비정상적으로 높게 측정되는 빈도가 줄어드는 것을 확인할 수 있었다.

Cartridge Valve를 이용한 유압시스템 개발에 관한 연구 (A Study on Development of Hydraulic Pressure System Using Cartridge Valve)

  • 이우;정석윤;김상구;김경훈;변승남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1279-1282
    • /
    • 2003
  • The hydraulic pressure system can deliver strong power and control is easy so that it have been applied to the element technique of an each industrial field. Apply range is the actual circumstances to be more widening according to the automation plant and trend of the manufacture facilities. The hydraulic pressure system have been used since early times and it was universalized considerable in the industrialized country. Utilized to an automation device instrument wide at an each industrial spot and contributed the air space development which contribution make great strides for robotics and airospace departments. Our circuit design technology for the device structure are weak and in fact domestic is depending on the income though importance of the hydraulic pressure system.

  • PDF

Design, Fabrication, and Application of a Microfluidic Device for Investigating Physical Stress-Induced Behavior in Yeast and Microalgae

  • Oh, Soojung;Kim, Jangho;Ryu, Hyun Ryul;Lim, Ki-Taek;Chung, Jong Hoon;Jeon, Noo Li
    • Journal of Biosystems Engineering
    • /
    • 제39권3호
    • /
    • pp.244-252
    • /
    • 2014
  • Purpose: The development of an efficient in vitro cell culture device to process various cells would represent a major milestone in biological science and engineering. However, the current conventional macro-scale in vitro cell culture platforms are limited in their capacity for detailed analysis and determination of cellular behavior in complex environments. This paper describes a microfluidic-based culture device that allows accurate control of parameters of physical cues such as pressure. Methods: A microfluidic device, as a model microbioreactor, was designed and fabricated to culture Saccharomyces cerevisiae and Chlamydomonas reinhardtii under various conditions of physical pressure stimulus. This device was compatible with live-cell imaging and allowed quantitative analysis of physical cue-induced behavior in yeast and microalgae. Results: A simple microfluidic-based in vitro cell culture device containing a cell culture channel and an air channel was developed to investigate physical pressure stress-induced behavior in yeasts and microalgae. The shapes of Saccharomyces cerevisiae and Chlamydomonas reinhardtii could be controlled under compressive stress. The lipid production by Chlamydomonas reinhardtii was significantly enhanced by compressive stress in the microfluidic device when compared to cells cultured without compressive stress. Conclusions: This microfluidic-based in vitro cell culture device can be used as a tool for quantitative analysis of cellular behavior under complex physical and chemical conditions.

공압 수직실린더의 쿠션특성에 관한 실험적 연구 (An Experimental Study on Cushion Characteristics of pneumatic Cylinder for Vertically-Mounted.)

  • 김동수;김형의;이상천
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.73-87
    • /
    • 1998
  • A pneumatic control system of compressed air as a working fluid has a variety of advantages such as low price, high respondence, non-explosion and good control performance and thus has many applications in the field of automobile, electronic and semiconductor industry. However, it has a difficulty in contolling a precise position due to quick response of system and compressibility of working fluid and. in particular, shock stress may occur due to an external load, resulting in fracture of a cylinder cap unless cushion device is equipped in the linear actuator. To avoid this, a cushion device should be installed for damping effect of the external load and the supply pressure as well as for decreasing shock stress and vibration caused by high speed rotation. Previous studies include dimensionless analyses and computer simulations of cushion capability and experiments of horizontally-mounted cylinder performances. A new attempt is experimentally made in this study using a vertically-mounted cylinder under an operation condition of 4, 5 and 6 (bar) as supply pressure and 40, 70 and 100 (kgf) as external load. It turns out that the cushion pressure is mainly a function of the external load rather than the supply pressure. The cushion characteristics was also revealed in the meter-in circuit.

  • PDF

Energetics of the Heart Model with the Ventricu1ar Assist Device

  • Chung, Chanil-Chung;Lee, Sang-Woo;Han, Dong-Chul;Min, Byoung-Goo
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.43-48
    • /
    • 1996
  • We investigated the energistics of the physiological heart model by comparing predictive indexes of the myocardial oxygen consumption (MOC), such as tension-time index (R), tension-time or force-time inteual (FTI), rate-pressure product (RPP), pressure-work index, and systolic pressure-volume area (PVA) when using the electro-hydraulic left ventricular device (LVAD). We developed the model of LVAD incorporated the closed-loop cardiovascular system with a baroreceptor which can control heart rate and time-varying elastance of left and right ventricles. On considering the benefit of the LVAD, the effects of various operation modes, especially timing of assistance, were evaluated using this coupled computer model. Overall results of the computer simulation shows that our LVAD can unload the ischemic (less contractile) heart by decreasing the MU and increasing coronary flow. Because the pump ejection at the end diastolic phase of the natural heart may increase the afterload of the left ventricle, the control scheme of our LVAD must prohibit ejecting at this time. Since the increment of coronary flow is proportional to the peak aortic pressure after ventricle contraction, the LVAD must eject immediately following the closure of the aortic valve to increase oxygen availability.

  • PDF

장쇄지방산 LB박막의 전류-전압 특성에 관한 연구 (A study on the I-V Properties of Long Chain Fatty Acid of LB Thin Films)

  • 전동규;장헌;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.913-919
    • /
    • 2000
  • We give pressure stimulation into long chain fatty acid of LB thin films then manufacture a device under the accumulation condition that the state surface pressure is 20[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Arachidic acid/Al, the number of accumulated layers are 13, 17 and 19. The I-V characteristic of the device is measured from 0[V] to +1.5[V]. We have investigated the capacitance because this fatty acid system have a accumulated layers. The maximum value of measured current is increased as the number of accumulated layers are decreased. The capacitor properties of a thin film is better as the distance between electrodes is smaller. The results have shown the insulating materials and could control the conductivity by accumulated layers.

  • PDF

블랭킷 실린더의 인압제어 기술개발 (Development of Technology for Printing Pressure Control of Blanket Cylinder)

  • 함영복;윤소남;김광영;최병오
    • 연구논문집
    • /
    • 통권32호
    • /
    • pp.15-22
    • /
    • 2002
  • In offset or intaglio printing machine, it's operated with combination of blanket cylinder and impression cylinder. The blanket cylinder has some number of grooves to attach the blanket on surface. In case of operating the printing machine, it has generate mechanical impact noise when the two cylinders encounter with the grooves. So, in this study, we developed a printing pressure control algorithm with hydraulic servo control system. We also proposed simulation model of experimental device to analysis the throw on force response of hydraulic servo actuator. Finally, we have reduced the mechanical impact noise and improved printing quality with a groove detecting signal and PI control of hydraulic servo actuator.

  • PDF

공기압 쿠션 실린더의 미터아웃/미터인 속도제어 특성에 관한 연구 (A Study on the Meter-Out and Meter-In Speed Control Characteristics in Pneumatic Cushion Cylinders)

  • 김도태
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2013
  • Pneumatic cylinders are widely used to actuators in automatic equipments because they are relatively inexpensive, simple to install and maintain, offer robust design and operation, are available in a wide range of standard sizes and design alternatives. This paper presents a comparative study among the dynamic characteristics of meter-out and meter-in speed control of pneumatic cushion cylinders with a relief valve type cushion mechanism. Because of the nonlinear differential equations and a requirement for simultaneous iterative solution in a mathematical model of a double acting pneumatic cushion cylinder, a computer simulation is carried out to investigate pressure, temperature, mass flow rate in cushion chamber and displacement and velocity time histories of piston under various operating conditions. It is found that the piston velocity and pressure response in meter-in speed control are more oscillatory than with meter-out those when pneumatic cushion cylinders are driven at a high-speed. In meter-out speed control, the effective area of the flow control valve is larger than that of meter-in, and the supply pressure has to be much higher than the pressure required to move the load because it has also to overcome the back pressure in cushion chamber.

압력 평형식 온도 조절 밸브의 유동특성 연구 (A study on the flow charateristics of temperature control valve by pressure compensation)

  • 김태안;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2001
  • TCV(Temperature control valve by pressure compensation) controls temperature constantly, when it is sending steam or high temperature water to heating device of heat exchanger. For designing TCV, the ratio of piston and hole diameters is one of the important design parameters. Numerical analysis is carried out to elucidate the flow characteristics in the TCV with different port areas of cold and hot waters, using the k-$\epsilon$ turbulence model and Cartesian cut-cell method. Numerical results show that the exit flow rate is mainly affected by pressure distribution in the piston.

  • PDF