• Title/Summary/Keyword: Preservatives.

Search Result 444, Processing Time 0.033 seconds

Reliability and Failure Analysis of the OSP(Organic Solderability Preservatives) Finished CSP Substrate (OSP(Organic Solderability Preservatives)처리된 CSP Substrate 특성 연구)

  • 이효수;김종호;신영환;이병호
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.6-9
    • /
    • 2003
  • 최근 휴대폰, PDA 등의 모바일 전자제품의 수요가 급격히 증가하고 마이크로 전자패키지 부품의 경박단소화에 의해서 고I/O수, 미세피치가 적용된 개발제품이 양산되고 있으나, 마이크로 전자패키지 부품의 생산비 및 솔더볼접합특성 등의 문제는 여전히 크게 이슈화 되고 있다. Organic solderability preservatives(OSPs)는 이러한 모바일용 마이크로 전자패키지 부품의 문제점을 낮은 단가로 해결할 수 있는 공정으로 평가되고 있다. 본 연구에서는 OSP 처리된 CSP의 열적특성, 화학적특성 및 기계적특성을 정량적으로 분석하여 OSP 응용범위를 제시하고자 하였다.

  • PDF

Detection of Chemical Preservatives by the Use of Fluorescence (형광(螢光)을 이용한 식품(食品) 방부제의 검사(檢査))

  • Lee, Mie-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.166-170
    • /
    • 1979
  • A rapid and simple method for detecting chemical preservatives was attempted on the basis of emitted fluorescence at the illumination of UVSL-25 mineral light. Absorption and fluorescence spectra of powdered samples dispersed in liquid paraffin revealed characteristic patterns depending on chemical preservatives. Detection of chemical preservatives was more readily accomplished by simultaneous comparison of spectral characteristics at long and short wave ranges of the exciting light.

  • PDF

Study on Simultaneous Analysis and Use of Preservatives in Mouthwashes (구강 청정제 중 보존제의 동시 분석법 확립과 사용실태에 관한 연구)

  • Jung, Sang-Mi;Moon, Tae-Jung;Kim, Jae-Dong;Lee, Gye-Won
    • Journal of Digital Convergence
    • /
    • v.10 no.6
    • /
    • pp.331-339
    • /
    • 2012
  • The easy and simple simultaneous analytical method of preservatives (BA, SA, DHA, MP, EP, IPP, PP, IBP and BP) was studied by more easily changing from method used in food and drug using HPLC with scherzo SM-C18 column. All presevatives were seperated successfully in mobile phase of 50 mM ammonium formate : 0.1% phosphoric acid (50:50 v/v%) and 50 mM ammonium formate : acetonitrile (30 : 70). Retention time of BA, SA, DHA, MP, EP, IPP, PP, IBP and BP was 7.74, 9.08, 12.57, 13.83, 21.62, 27.29, 28.20, 33.20 and 33.68 min, respectively. The calibration curves of BA, SA, DHA, MP, EP, IPP, PP, IBP and BP were linear over the concentration range of 5~80 ${\mu}g/mL$ with correlation coefficient of above 0.999. The limit of detection (LOD) and limit of quantitation (LOQ) of BA, SA, DHA, MP, EP, IPP, PP, IBP and BP were 0.52 and 1.58, 1.09 and 3.29, 1.00 and 3.03, 1.36 and 4.13, 1.26 and 3.83, 1.02 and 3.08, 1.11 and 3.37, 0.82 and 2.48, 0.85 and 2.59 ${\mu}g/mL$, respectively. The coefficients of variation for intra- and inter-day assay were 0.12~2.68 and 0.18~2.66%, respectively. The developed method showed good intra- and inter-day precision and accuracy. The preservatives used in mouthwashes were BA, MP and PP and were detected in 24 samples(86%) except for 4 samples and not showed significant difference in using dose of adult and children. In conclusion, the developed method can be useful for simultaneous analysis of preservatives in mouthwashes and these results suggest that could be applied to fundamental study and guideline on content of preservatives in mouthwashes.

Current Research Trends in Wood Preservatives for Enhancing Durability - A Literature Review on Non-Copper Wood Preservatives - (옥외 내구성 향상을 위한 목재보존제의 최근 연구 동향 -비 구리계 약제를 중심으로-)

  • Kim, Yeong-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.187-200
    • /
    • 2013
  • Current research trends of non-copper wood preservatives for enhancing durability was reviewed; as a follow-up of the review in 2012 on copper-based wood preservatives. Main environmental friendly non-copper wood preservatives studied by many scientists were boron-based compounds, synthetic compounds from natural products, and pyrethroids family of chemicals, etc. The critical issue regarding treated woods with boron-based compounds used outdoors was the leaching of boron. Many studies mainly focused on boron fixation improvement using variety of polymers. Moreover, the studies showed notable increases in attempts to use natural products used commonly in the medical fields as wood preservatives as well as outdoor use of chemical modified such as acetylated wood developed in purpose of stabilizing dimension.

Effects of Natural Preservatives and Storage Temperatures on Quality and Shelf-life of Fresh Pork Meat (천연 보존제와 저장 온도가 돈육의 품질과 Shelf-life에 미치는 영향)

  • Tak, Sang-Bum;Kim, Dong-Ho;Yoon, Suk-Kwon;Lee, Young-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.557-561
    • /
    • 2005
  • Effects of natural preservatives on quality and shelf-life of fresh pork were investigated by evaluating changes in physicochemical properties, sensory evaluation, and mcrobial properties during storage. Acidity and VBN values of pork with preservatives were lower than those of control. Total bacterial count of pork with preservatives was significantly lower than that of control during storage. Sensory results showed pork with preservatives had lower sensory color and off-flavor scores than control. Changes in pH, VBN, total bacterial count, coliform group, and sensory evaluation revealed pork with preservatives showed less quality changes than control during storage, regardless of storage temperature. Results indicated that addition of preservatives to pork increased shelf-life by 7 days at $4^{\circ}C$.

A Study of Influencing Factors for Sensory Irritation Due to Preservatives of Cosmetics (방부제에 의해 유발되는 자극감에 대한 화장품에서의 영향 요인 연구)

  • Lee, Eun-Young;Choi, Dong-Won;An, Su-Sun;Moon, Seong-Joon;Chang, Ih-Seop;Eun, Hee-Chul
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.1 s.55
    • /
    • pp.65-68
    • /
    • 2006
  • Sensory irritation is one of the important side effects of cosmetics and it is required to develop new products that are more tolerable to the consumers. There are lots of cosmetic ingredients known to induce sensory irritation such as lactic acid, glycolic acid, ethanol, preservatives, fragrances and menthol etc. It is also known that sensory irritation increases by change of pH as well as additional occlusive conditions. The aim of this study is to know various factors affecting sensory irritation due to preservatives (methylparaben, propylparaben, phenoxyethanol and chlorophenecin). We also wanted to investigate the effect of preservatives to sensory irritation according to change of formulations. Our results showed that sensory irritation increased with the conditions of increasing absorption such as packs. We have also found that sensory irritation increased synergistically when to apply two different preservatives together. For example, phenoxyethanol and chlorphenesin themselves have weak sensory irritation potentials, but we observed phenoxyethanol combined with chlorpenesin synergistically increase of sensory irritation potentials. In conclusion, formulation and combination of different preservatives should be considered to reduce the unwanted sensory irritation of preservatives.

Monitoring of Pesticide Residues and Preservatives in Cosmetics Using Natural Materials (천연물질 사용 화장품의 잔류농약과 보존제 모니터링)

  • Park, Eun-Mi;Um, Mi-Na;Kim, Beom-Ho;Cho, Sang-Hun;Park, Sin-Hee;Jo, Hyun-Ye;Yoon, Mi-Hye;Lee, Jong-Bok
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.257-263
    • /
    • 2012
  • Cosmetics using natural materials which was purchased in retail stores, distributed in Gyeonggi province(32 samples) and online through internet(24 samples) were analyzed by pesticide residues and target preservatives for assessing the safety of it. Natural or organic certifications was identified in 22 samples among 56 samples and most of them were Ecocert. Pesticide residues was detected in 3 samples among 56 samples and each compound and concentration was permethrin(0.6 mg/kg), tricyclazole(11.7 mg/kg) and malathion(0.05 mg/kg). All of it was purchased through internet. Target preservatives was detected in 13 samples among 56 samples and one of them was over the maximum allowed concentration and the rest of them were within the maximum allowed concentration of the respective preservatives. The compound which was over the maximum allowed concentration was benzoic acid and compounds which were within the maximum allowed concentration were sorbic acid, benzoic acid and methylparaben. They were all identified substances in products and the number of detected preservatives in retail stores were higher than online samples purchased through internet. As a result of this study, The method of analyzing pesticide residues and limit in cosmetics using natural materials should be set up as soon as possible and the monitoring about preservatives in cosmetics using natural materials should be conducted on continuously.

Antimicrobial Effect of Mustard, Cinnamon, Japanese Pepper and Horseradish (겨자.계피.산초.고추냉이의 항균성 효과)

  • 양지영;한종흔;강현록;황미경;이재우
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.1
    • /
    • pp.37-40
    • /
    • 2001
  • Recently, consumer's demand for natural preservatives is increasing because of residual toxicity, mutagenicity and etc. of synthetic preservatives and th study of natural preservatives is being done. In this study, antimicrobial activity of spices was investigated. Fungi occurred in bread and d noodle without mustard after 3days and 4days, respectively. However, they didn't occured in bread and noodle with mustard ball. Temperature of the water used in mixing-up mustard powder didn't affect antimicrobial activity of mustard. Fungi occurred in bread with cinnamon, Japanese pepper or horseradish after 4days, 4days or 6days, respectively. However, there wasn't the occurrence of fungi in bread with mustard after 8days, yet. Mustard and horseradish of extracts by water of spices had a strong antimicrobial activity. But the extracts by ethanol had 1ow antimicrobial activity.

  • PDF

Studies on Synthetic Preservatives in Foods -Part 1. Simultaneous Gas Chromatographic Determination of Sorbic Acid, Dehydroacetic Acid, Benzoic Acid, Butyl p-Hydroxybenzoate- (식품중(食品中)의 보존료(保存料)에 관(關)한 조사연구(調査硏究) (제1보)(第1報) -Gas Chromatography 에 의(依)한 Sorbic Acid, Dehydroacetic Acid, Benzoic Acid, Butyl p-Hydroxybenzoate의 동시정량(同時定量)-)

  • Ro, Hong-Shik
    • Korean Journal of Food Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.24-28
    • /
    • 1972
  • Synthetic food preservatives were analysed in foods collected in Seoul area on Aug. 10, 1971. Sorbic acid, benzoic acid, dehydroacetic acid and butyl p-hydroxybenzoate were determined by the simultaneous gas chromatography using FID at $200{\circ}C$ and a column of Chromosorb W coated with 5% $DGS{\sim}1%\;H_3PO_4$. The recovery rates of each preservative were from 76.7% to 96.3%. The calibration curves show linearity within a range from 0.3 to $2.5{\mu}g$ of standard preservatives. The results obtained were as follows: 1) Benzoic acid was used as well as butyl p-hydroxybenzoate in soy. 2) Sorbic acid was not found in soy. 3) From all breads and biscuits benzoic acid was found as trace. 4) Detected preservatives were below the range of permitted limit. 5) From 2 soy among 15 samples dehydroacetic acid was found.

  • PDF

Studies on Analytical Methods of Preservatives in Food (식품중 보존료의 분석방법에 관한 연구)

  • 김명희;엄석원;박성배
    • Journal of Food Hygiene and Safety
    • /
    • v.3 no.4
    • /
    • pp.203-209
    • /
    • 1988
  • This study was performed to develop the simple and rapid determination method of preservatives in Yogurt and Soybean.sauce. 1. The analytical method by HPLC system was as follow: The sample was diluted, centrifuged, filtered, if necessary, and analyzed by HPLC system with UV detector. 2. The analytical method by GLC system was as follow: The sample was extracted directly with ether, added cone. sulfuric acid to destroy emulsion and analyzed by the GLC system with FID. 3. The recovery rates of preservatives by the above methods were higher than 99.0 %. 4. Total running time for the above methods was less than 50 minutes. Especially, the running time for dilution method by HPLC system was one-third of that for GLC method.

  • PDF