• 제목/요약/키워드: Prefabricated material

검색결과 60건 처리시간 0.026초

Analysis of underground post-tensioned precast concrete box utility tunnel under normal fault displacement

  • Wu, Xiangguo;Nie, Chenhang;Qiu, Faqiang;Zhang, Xuesen;Hong, Li;Lee, Jong-Sub;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • 제29권2호
    • /
    • pp.69-79
    • /
    • 2022
  • For long underground box utility tunnels, post-tensioned precast concrete is often used. Between precast tunnel segments, sealed waterproof flexible joints are often specified. Fault displacement can lead to excessive deformation of the joints, which can lead to reduction in waterproofing due to diminished contact pressure between the sealant strip and the tunnel segment. This paper authenticates utilization of a finite element model for a prefabricated tunnel fault-crossing founded on ABAQUS software. In addition, material parameter selection, contact setting and boundary condition are reviewed. Analyzed under normal fault action are: the influence of fault displacement; buried depth; soil friction coefficient, and angle of crossing at the fault plane. In addition, distribution characteristics of the utility tunnel structure for vertical and longitudinal/horizontal relative displacement at segmented interface for the top and bottom slab are analyzed. It is found that the effect of increase in fault displacement on the splice joint deformation is significant, whereas the effects of changes in burial depth, pipe-soil friction coefficient and fault-crossing angle on the overall tunnel and joint deformations were not so significant.

철골공사 현장조사를 통한 설계프로세스 개선방안 (The Improvement Plan of Design Process by Case Study of Steel Structural Work)

  • 방성원;오승준;김진호;임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.121-126
    • /
    • 2003
  • Steel frame construction is divided into subsidiary materials with column, beam, girder and bracing. After these are processed in factory for using installing in construction field. These prefabricated furniture is very important in accordance with design drawing about processing and prefabricating. In the case of design process using information transmission in blueprint, omission of material number, processing measure and finishing material, or discordance of each structure drawing and selecting incongruent structural material generated an error in the process of design. These error caused delaying tine and increasing cost and increasing safety accident in the steel-structure work operating process. therefore, design process should consider problem of operating process.

  • PDF

현장조사를 통한 철골공사 설계프로세스 개선방안 (The Improvement Plan of Design Process by Case Study of Steel Structural Work)

  • 방성원;김진호;임남기
    • 한국건축시공학회지
    • /
    • 제3권2호
    • /
    • pp.111-118
    • /
    • 2003
  • Steel frame construction is divided into subsidiary materials with column, beam, girder and bracing. After these are processed in factory for using installing in construction field. These prefabricated furniture is very important in accordance with design drawing about processing and prefabricating. In the case of design process using information transmission in blueprint, omission of material number, processing measure and finishing material, or discordance of each structure drawing and selecting incongruent structural material generated an error in the process of design. These error caused delaying time and increasing cost and increasing safety accident in the steel-structure work operating process. therefore, design process should consider problem of operating process.

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

온도에 따른 케이블 직선 접속재 모델링 EPOXY/EPDM 계면의 파괴 특성에 관한 연구 (A study on analysis of interfacial breakdown properties with variable temperalure in straight cable Joint modeling EPGXY/EPOM interface)

  • 배덕권;정인재;김상걸;정일형;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.532-535
    • /
    • 1999
  • In power cable joints, the interfaces of two different dielectric materials are inevitable. In addition, the interfacial breakdown between two internal dielectric surfaces represents one of the major causes of failure for power cable joints. We chose epoxy/EPDM interface, one of the interface in cable joints, and investigate dielectric interfacial breakdown phenomenon. First, design specimen with Flux 2D. Second, find interface condition which has high dielectric strength. Third, investigate interfacial breakdown properties with variable temperature.

  • PDF

UHV STM을 이용한 유기 초박막의 전기적 특성 연구 (Electrical Characteristics of Self-Assembled Organic Thin Films Using Ultra-High Vacuum Scanning Tunneling Microscopy)

  • 김승언;신훈규;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.108-111
    • /
    • 2003
  • Currently, molecular devices are reported utilizing active self-assembled monolayers containing the nitro group as the active component, which has active redox centers[1]. We confirm the electrical properties of 4,4-di(ethynylphenyl)-2'-nitro-1-benzenethiolate. To deposit the SAM layer onto gold electrode, we transfer the prefabricated Au(111) substrates into a 1mM self-assembly molecules in THF solution. Au(111) substrates were prepared by ion beam sputtering method of gold onto the silicon wafer. As a result, we measured current-voltage curve using ultra high vacuum scanning tunneling microscopy (UHV STM), I-V curve also clearly shows several current peaks between the negative bias region (-0.3958V) and the positive bias region (0.4658V), respectively.

  • PDF

에어캡 적층을 통한 에어캡 벽 모듈 개발 (Development of Aircap Wall Module through the Lamination of Aircap)

  • 김경수;서장후;김용성;이행우
    • 설비공학논문집
    • /
    • 제29권10호
    • /
    • pp.504-514
    • /
    • 2017
  • The insulation performance of aircaps has been recognized and various studies regarding the aircap as a solution to increased building energy consumption are being carried out. However, the aircap is not durable and therefore it cannot play the role of an independent finishing material. Accordingly, the purpose of this study is to suggest an aircap wall module with improved durability through the lamination of the aircap and verify its effectiveness by evaluating its energy saving performance for lighting and air conditioning through a full-scale testbed. The conclusions of this study are as follows. 1) The aircap wall module featuring a laminated aircap that is being proposed in this study can save lighting energy due to the permeability of the aircap in comparison to previous insulating materials. 2) The aircap wall module with a laminated aircap is effective in improving heating and air-conditioning energy saving when it is more than 15 cm-thick during summer and winter in comparison to a 5 cm-thick prefabricated panel. 3) The aircap wall module featuring a laminated aircap is effective in improving lighting and heating and air-conditioning energy saving when it is 10 cm- and 5 cm-thick during summer and winter, respectively, in comparison to a 5 cm-thick prefabricated panel.

The effect of coloring liquid dipping time on the fracture load and color of zirconia ceramics

  • Orhun, Ekren
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.67-73
    • /
    • 2017
  • PURPOSE. The aims of the study were to evaluate the fracture load of zirconia core material after dipping in coloring liquid at different time intervals and to compare the color of dipped blocks with that of prefabricated shaded blocks. MATERIALS AND METHODS. 3-unit bridge frameworks were designed digitally. Sixty frameworks were fabricated using uncolored zirconia blocks by CAD/CAM and divided into 4 groups randomly (n = 15). Group 2 (G2) was subjected to coloring liquids for 2 minutes, Group 4 (G4) for 4 minutes, and Group 6 (G6) for 6 minutes. CFS group was not subjected to any coloring procedure. After coloring, color differences between the test groups and a prefabricated shaded zirconia group (CPZ, n = 15) were evaluated by using a spectrophotometer. Fracture test was conducted immediately after shade evaluation with a Testometric test device at a cross-head speed of 1 mm/sec. Statistical analysis for evaluating color and fracture load was performed by using one way ANOVA followed by Tukey HSD test ($P{\leq}.05$). Weibull analysis was conducted for distribution of fracture load. RESULTS. There was no difference in terms of fracture load and color between CFS (1176.681 N) and G2 (985.638 N) group and between CPZ (81.340) and G2 (81.140) group, respectively. Fracture load values of G4 (779.340 N) and G6 (935.491 N) groups were statistically significantly lower than that of CFS group ($P{\leq}.005$). The color values of G4 (79.340) and G6 (79.673) groups were statistically different than that of CPZ group ($P{\leq}.005$). CONCLUSION. Prolonged immersion of zirconia in coloring liquid not only negatively affected the fracture load of the zirconia being tested in the current study but also deteriorated the desired shade of the restoration.

치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구 (Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants)

  • 김희은;조인호
    • 구강회복응용과학지
    • /
    • 제29권3호
    • /
    • pp.209-223
    • /
    • 2013
  • 하악 제 1대구치에 티타늄과 지르코니아 소재의 기성 지대주와 맞춤형 지대주를 이용해 지르코니아 크라운으로 수복한 경우를 3차원 유한요소법을 통해 응력 분포를 분석해 보고, 피로 파절 강도 및 파절 형태를 고찰해 보았다. 정상교합자의 CT scan을 재구성한 하악골 모형상에 제 1대구치 임플란트 지지 지르코니아 크라운으로 수복한 6가지 유한요소 모형을 제작하고, 협측 교두 중앙에 수직과 30도 각도로 100 N의 하중을 가하는 조건으로 응력분포를 분석하였다. 현재 임상적으로 사용되고 있는 4가지 지대주를 이용하여, 군당 10개의 시편을 제작하고, ISO 14801에 따라 피로파절 실험을 실시하였다. 지대주나 고정체의 재질에 따른 응력분포의 차이는 없었고 형태에 따른 응력크기의 차이만 보였다. 맞춤형 지대주 군이 전반적으로 낮은 크라운 응력을 나타내었으며, 지대주 일체형 지르코니아 임플란트는 계면 골조직의 응력이 가장 낮게 나타났다. 피로수명의 평균값은 7군이 가장 높았고, 1군, 2군, 3군의 순서로 낮게 나타났으며(P<0.05), 기성 지대주 군은 피로수명의 편차가 적게 나타났다. 구치부의 임플란트 수복 시에는 맞춤형 지대주의 사용이 상부 보철물의 파절저항성 향상에 유리하며, 심미적 요구도가 높은 경우에는 고정체와의 접합부를 티타늄으로 제작한 지르코니아 맞춤형 지대주의 사용을 고려해 볼 만 하다.

KINKING DEFORMATION OF PVD UNDER CONSOLIDATION OF NATURAL CLAY LAYER

  • Aboshi, Hisao;Inoue, Toshiyuki;Yamada, Yoshimitsu
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.349-356
    • /
    • 2003
  • Almost every material of PVD (Prefabricated Vertical Drain) has the fatal problem on the condition - the length must shorten with the settlement of the surrounding grounds - which all PVDs must satisfy. Kinking deformation by buckling of PVD due to consolidation settlement Is discussed in this paper. A new testing device to clarify the deformation of PVD under consolidation of surrounding clay was developed and the fiber drain and a PVD made of plastics were compared under the same condition of consolidation using natural clay specimens. The results are also shown in this paper.

  • PDF