• Title/Summary/Keyword: Predicted power

Search Result 1,304, Processing Time 0.029 seconds

Wind Mapping of Singapore Using WindSim (WindSim을 이용한 싱가폴 바람지도 작성)

  • Kim, Hyun-Goo;Lee, Jia-Hua
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.839-843
    • /
    • 2011
  • We have established a wind map of Singapore, a city-state characterized its land cover by urban buildings to confirm a possibility of wind farm development. As a simple but useful approximation of urban canopy, a zero-plane displacement concept was employed. The territory is divided into 15 sectors having similar urban building layouts, and zero-plane displacement, equivalent roughness height at each sector was calculated to setup a terrain boundary condition. Annual mean wind speed and mean wind power density map were drawn by a CFD micrositing model, WindSim where Changi International Airport wind data was used as an in-situ measurement. Unfortunately, predicted wind power density does not exceed 80 $W/m^2$ at 50 m above ground level which would not sufficient for wind power generation. However, the established Singapore wind map is expected to be applied for wind environment assessment and urban planning purpose.

Performance Analysis of Axial-Flux Permanent-Magnet Synchronous Generator for Wind Power Applications (횡자속형 영구자석 풍력발전기의 운전특성 해석)

  • Hwang, Don-Ha;Kang, Do-Hyun;Kim, Yong-Joo;Choi, Kyeong-Ho;Bae, Sung-Woo;Kim, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.143-145
    • /
    • 2003
  • In this paper, wind power system with direct-driven axial-flux type permanent-magnet (PM) synchronous generator, 10 [kVA], 300 [rpm], is presented. In order to analyze the performance of axial PM generator, finite-element (FE) analysis is used, and the 2-dimensional equivalent model is developed. The steady-state and transient-state characteristics are respectively analyzed at no-load and resistive-inductive loads. The test results of driving characteristics are presented as well. The results are very similar to predicted performance of design. Proposed generator is feasible for use with a small-class wind power applications.

  • PDF

Low Cycle Fatigue Behavior of 12Cr Steel for Thermal Power Plant Steam Turbine (화력발전소 증기터빈용 12Cr 강의 저주기 피로거동)

  • Kang, Myeong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.8
    • /
    • pp.71-76
    • /
    • 2002
  • In this study low cycle fatigue (LCF) behavior of 12Cr steel at high temperature are described. Secondly, comparisons between predicted lives and experimental lives are made for the several sample life prediction models. Two minute hold period in either tension or compression reduce the number of cycles to failure by about a factor of two. Twenty minute hold periods in compression lead to shorter lives than 2 minute hold periods in compression. Experiments showed that life predictions from classical phenomenological models have limitations. More LCF experiments should be pursued to gain understanding of the physical damage mechanisms and to allow the development of physically-based models which can enhance the accuracy of the predictions of components. From a design point-of-view, life prediction has been judged acceptable for these particular loading conditions but extrapolations to thermo-mechanical fatigue loading, for example, require more sophisticated models including physical damage mechanisms.

Performance Evaluation of the Samcheonpo Small-Hydro Power Plant (삼천포 해양소수력 성능평가)

  • Cho, Hong-Yeon;Cho, Beom-Jun;Kang, Geum-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.617-620
    • /
    • 2007
  • The performance evaluation of the Samcheonpo small-hydropower plant constructed on the October 25th,2006, was carried out focused on the turbine and generator efficiency analysis by using the measurement data. The unreasonable and unrealistic efficiency results are occurred in some periods because of the data variability, uncertainty, and measurement errors and mistakes. Whereas, the big mismatch is the tidal elevation predicted in the design processes. The difference between the measured and estimated tidal elevation is obvious during the low water period. It should be considered and checked in depth on the efficiency analysis of the planned and constructing small-hydro power plants in other coastal areas.

  • PDF

Research on the Development Direction of Wireless Charging Technology Using Patent Analysis (특허분석을 통한 무선충전 기술방향 분석)

  • Yang, Dong Won;Lee, Haeng Byoung
    • Journal of Information Technology Services
    • /
    • v.19 no.3
    • /
    • pp.89-100
    • /
    • 2020
  • The wireless power transmission market is growing at an average annual rate of 51.5% from $ 16.4 billion in 2015 to $ 131.1 billion in 2020. However, there are limitations to commercialization due to the development of standards and technologies. Thus, this study identified trends in standards and regulations by market and by country. The research collected and filtered a total of 69,488 worldwide wireless power transfer patents by June 2019 and extracted a total of 28,555 patents. Based on this, technology development status was analyzed and predicted. In this study, long-distance and short-range technology development with high technology development difficulty and low technology development ratio could lead to growth of the entire wireless charging market. It is analyzed that investment and policy preparation are necessary to secure source technology for long-distance / near technology development than China, Japan and Europe.

DC-DC Converter with High Efficiency for PDP (높은 전력변환 효율을 갖는 PDP용 DC-DC 컨버터)

  • Kang Won-Suck;Ahn Tae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.369-373
    • /
    • 2004
  • Recently the PDP is the most remarkable media for a next generation display device. In this paper, we proposed the PDP dedicated DC-DC converter using quasi-resonant method because the PDP has a lot of power dissipation so we need to develope. The proposed converter using one transformer has soft switching and a advantage to lower voltage stress in switch and also is predicted to have high power efficiency. we proposed the principles and theory using the zero voltage switching and verified the validity through a experiment.

  • PDF

Analysis of Operation Performance of a Micro Gas Turbine Generator System (마이크로 가스터빈 발전시스템의 운전성능 분석)

  • Lee, J. J.;Kim, T. S.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.5 s.32
    • /
    • pp.13-21
    • /
    • 2005
  • This study aims to analyze operating performance of a micro gas turbine with the aid of detailed measurements of various system parameters. In addition to embedded measurements, parameters such as exhaust temperatures, engine inlet temperatures and fuel flow rates are measured. Variations in measured data and estimated performance parameters are analyzed. Those data are processed to calculate losses along the power transmission line and the net gas turbine performance (power and efficiency based on the gas turbine shaft end) is isolated from the overall system performance. A method to estimate characteristic parameters such as component efficiencies, based on the comparison between measured and predicted performance data, is suggested and exemplified for the full load condition.

Power Transmission Characteristics and Speed Ratio-Torque Load-Axial Force Relationship for a Metal V-Belt CVT (금속 V-벨트 CVT의 동력전달 특성과 변속비-부하토크-축력 관계)

  • 김광원;김현수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.349-357
    • /
    • 1990
  • Power transmission characteristics and speed ratio-torque load-axial force relationship for a metal V-belt CVT were investigated theoretically and experimentally. In the metal V-belt CVT drive, it was found that the power was transmitted by thrust force and that band tension should be greater than compression force between the metal blocks. The experimental results for the speed ratio-torque load-axial force relationship showed good agreement with those predicted using equations developed from theoretical considerations.

Analysis of Start-Up Characteristics of Gas Turbines for Power Generation (발전용 가스터빈의 시동특성 해석)

  • Kim, Jae-Hwan;Song, Tae-Won;Kim, Tong-Seop;Ro, Sung-Tack
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.662-667
    • /
    • 2000
  • A simulation procedure for a full transient analysis of the start-up of heavy-duty gas turbines for power generation is constructed. Compressor stages are grouped into three categories (front, mid, rear) and three different stage characteristic curves are applied to consider the different low-speed operating characteristics. Start-up behavior of a typical single-shaft gas turbine for power generation is simulated. The predicted transient behavior shows a good agreement with the field data. Special attention is paid to the effects of the modulation of VIGV on start-up characteristics, which play a key role in the stable operation of gas turbines.

  • PDF

Experimental Study On Power Flow Finite Element Method of Vibration of a Plate Partially Covered with a Damping Sheets (부분 제진 평판 진동 해석을 위한 파워흐름유한요소법의 실험적 연구)

  • Lee, Y.H.;Lee, J.Y.;Kil, H.G.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.496-497
    • /
    • 2009
  • In this paper the power flow finite element method (PFFEM) has been used to analyze the vibration of a plate partially covered with a damping sheet. Experiments have been performed to measure the loss factor and frequency response functions of the plate partially covered with the damping sheet. The data for the loss factor has been used as the input data to predict the vibration of the coupled plates with PFFEM. The comparison between the experimental results and the predicted PFFEM results for the frequency response functions has been performed. It showed that PFFEM can be effectively used to predict structural vibration in medium-to-high frequency ranges.

  • PDF