DOI QR코드

DOI QR Code

Analysis of Operation Performance of a Micro Gas Turbine Generator System

마이크로 가스터빈 발전시스템의 운전성능 분석

  • 이종준 (인하대학교 대학원 기계공학부) ;
  • 김동섭 (인하대학교 기계공학부)
  • Published : 2005.10.01

Abstract

This study aims to analyze operating performance of a micro gas turbine with the aid of detailed measurements of various system parameters. In addition to embedded measurements, parameters such as exhaust temperatures, engine inlet temperatures and fuel flow rates are measured. Variations in measured data and estimated performance parameters are analyzed. Those data are processed to calculate losses along the power transmission line and the net gas turbine performance (power and efficiency based on the gas turbine shaft end) is isolated from the overall system performance. A method to estimate characteristic parameters such as component efficiencies, based on the comparison between measured and predicted performance data, is suggested and exemplified for the full load condition.

Keywords

References

  1. Rodgers, C., Watts, J., Nichols, K. and Brent, R., 2001, Microturbines, in Distributed Generation, Borbely, A.M. and Kreider, J, ed., CRC Press, pp. 119-150
  2. Haught, D., 2003, Microturbine Equipment, Panel session presented at ASME Turbo Expo 2003, June 16-19, Atlanta, Georgia, U.S.A.(also see http://www.eere.energy.gov/de/conf-03_turbo_expo.html.)
  3. Kang, Y. M. and KcKeirnan, R., 2003, 'Annular Recuperator Development and Performance Test for 200kW Microturbine,' ASME paper GT-2003-38522
  4. Shibata, R., Nakayama, Y., Machiya, S. and Kobayashi, K., 2003, 'The Development of 300kW Class High Efficiency Micro Gas Turbine RGT3R,' IGTC 2003 Tokyo TS-115, International Gas Turbine Congress 2003, Tokyo, Japan, 2-7 November
  5. 오종식, 이헌석, 2003, '분산발전용 75kW급 마이크로터빈의 시제개발,' 유체기계연구개발발표회 논문집, pp. 307-313
  6. 김수용, 박무용, 최범석, 안국영, 최상규, 2003, '50kW 마이크로 가스터빈 개발,' 유체기계연구개발발표회 논문집, pp. 314-319
  7. 권기훈, 김승우, 이시우, 2003, '분산형 마이크로 터빈 열병합 발전시스템 개발,' 유체기계연구개발발표회 논문집, pp. 320-327
  8. McDonald, C. F., 2000, 'Low-cost Compact Primary Surface Recuperator Concept for Microturbines,' Applied Thermal Engineering, Vol. 20, pp. 471-497 https://doi.org/10.1016/S1359-4311(99)00033-2
  9. UTC Power, http://www.utcpower.com/html/microturbine.shtml
  10. 이준희, 김동섭, 2004, '마이크로 가스터빈과 유기매체 랜킨사이클을 결합한 복합시스템의 설계 성능해석,' 대한설비학회 동계학술대회 논문집, pp. 131-138
  11. 김동섭, 황성훈, 2004, '마이크로 가스터빈의 탈설계 운전 성능특성,' 유체기계저널, 제7권, 제3호, pp. 39-47 https://doi.org/10.5293/KFMA.2004.7.3.039
  12. Capstone Turbine Co., http://www.microturbine.com/Documents/C30.pdf
  13. Maghon, H., Kreutzer, A. and Termuehlen, H., 1988, 'The V84 Gas Turbine Designed for Reliable Base Load and Peaking Duty,' American Power Conference, Chicago, Ilinois, U.S.A
  14. 김동섭, 노승탁, 1996, '단축 가스터빈의 설계점 및 부분부하 성능해석 프로그램 개발,' 대한기계학회 논문집 B, 제20권, 제7호, pp. 2409-2420
  15. Bettocchi, R. and Spina, P. R., 1999, 'Diagnosis of Gas Turbine Operating Conditions by Means of the Inverse Cycle Calculation,' ASME paper 99-GT-185

Cited by

  1. Analysis of Performance Enhancement of a Microturbine by Water Injection vol.12, pp.2, 2009, https://doi.org/10.5293/KFMA.2009.12.2.046