• Title/Summary/Keyword: Power-line protocol

Search Result 68, Processing Time 0.025 seconds

Design and Implementation of Certification Tool for Home Network Control Protocol(HNCP) Based Power Line Communication (전력선통신에 기반한 홈네트워크 제어프로토콜(HNCP) 인증툴의 설계 및 구현)

  • 정수영;이재민;이명언;김태현;권욱현
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.561-564
    • /
    • 2003
  • HNCP 홈네트워크 인증 툴이란 홈네트워크에서 사용하고자 하는 디바이스가 HNCP 스펙에 맞게 구현되었는가를 인증해 주는 툴이다. 본 논문에서는 먼저 HNCP 인증 툴의 전체 구조에 대해 설명하고, 인증 툴에서 자동으로 실행되는 인증 과정에 대해 설계 및 구현한다.

  • PDF

Performance Evaluation of HNCP Home Network Using Stochastic Activity Network Models (Stochastic Activity Network 모델을 이용한 HNCP 홈 네트워트 성능 평가)

  • 이재민;명관주;이감록;전요셉;권욱현
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.183-186
    • /
    • 2003
  • In this paper, performance evaluation of HNCP home network is using stochastic activity network models is proposed. HNCP is a home network protocol for controling and monitoring home appliances using power line communication. a CSMA/CA with packet drop method is used in HNCP MAC layer. Using the proposed stochastic activity network models. performances of HNCP home networks with error-free environment and error environment are evaluated.

  • PDF

Power Line Communication Protocol Design for street light control (가로등 제어를 위한 전력선 통신 프로토콜의 설계)

  • Park, Chong-Yeon;Choi, Won-Ho;Lim, Ki-Seung;Choi, Hyeon-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1994-1995
    • /
    • 2007
  • 본 논문에서는 가로등 제어를 위한 전력선 통신 프로토콜을 OSI 7계층을 바탕으로 설계하고, 실제 적용해 봄으로써 그 실용성을 입증한다. 그러나 전력선 채널의 상태가 좋지 않으면 멀리 있는 모뎀까지의 전송 확률이 떨어짐을 확인하였다.

  • PDF

Design and Implementation of Monitoring Software for Heterogeneous Control Network (이종 제어 네트워크를 위한 모니터링 소프트웨어의 설계 및 구현)

  • Heo, Jong-Man;Ha, Jae-Yeol;Kim, Nam-Hoon;Jeon, Joseph;Lee, Kam-Rok;Chung, Bum-Jin;Kwon, Wook-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.114-116
    • /
    • 2006
  • XCP (eXtensive Control Protocol) is an information oriented protocol which delivers information with high reliability according to the predefined rule. XCP network system can be implemented on top of several physical layer such as power line, IEEE 802.15.4 and so on. In this paper. a monitoring software that evaluates the reliability and performance of the XCP network is designed and implemented. This paper presents the structure and method of the packet monitoring in the network through several interfaces such as RS-232, ethernet.

  • PDF

A Study on Leakage of Critical Information via the Power Analysis of Power Lines (전원선의 전력분석을 이용한 주요정보 유출 가능성에 관한 연구)

  • Han, Kyong-Ho;Lee, Seong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1571-1574
    • /
    • 2014
  • In this paper, we propose a unidirectional transmission of critical information obtained by keyboard hacking or kernel and keyboard driver hacking even though the computer is not connected to the external network. We show the hacking can be attempted in the proposed method to show the way preventing such attempts in advance. Firewalls and other various methods are used to prevent the hacking from the external network but the hacking is also attempted in various ways to detour the firewall. One of the most effective way preventing from the hacking attack is physically disconnect the internal intranet systems from the external internet and most of the government systems, military systems and big corporate systems are using this way as on one of the protection method. In this paper, we show the feasibility of transmission of security codes, etc via the short message to the external network on the assumption that a hacking program such as Trojan Horse is installed on the computer systems separated from the external network. Previous studies showed that the letters on the monitor can be hijacked by electromagnetic analysis on the computer to obtain the information even though the system is not connected ti the network. Other studies showed that the security code hint can obtained by analyzing the power consumption distribution of CPU. In this paper, the power consumption distribution of externally accessible power line is analyzed to obtain the information and the information can be transmitted to the external network. Software controlling the CPU and GPU usage is designed to control the power supply of computer. The sensors such as the Rogowski coils can be used on the external power line to collect the data of power consumption change rates. To transmit the user password by short message, due to the capacitive components and the obstacle from other power supply, A very slow protocol are used.

Test Platform Development of Vessel's Power Management System Using Hardware-in-the-Loop Simulation Technique

  • Lee, Sang-Jung;Kwak, Sang-Kyu;Kim, Sang-Hyun;Jeon, Hyung-Jun;Jung, Jee-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2298-2306
    • /
    • 2017
  • A PMS (Power Management System) controls vessel's power systems to improve the system efficiency and to protect a blackout condition. The PMS should be developed with considering the type and the capacity of the vessel's power system. It is necessary to test the PMS functions developed for vessel's safe operations under various sailing situations. Therefore, the function tests in cooperation with practical power systems are required in the PMS development. In this paper, a hardware-in-the-loop (HIL) simulator is developed for the purposes of the PMS function tests. The HIL simulator can be more cost-effective, more time-saved, easier to reproduce, and safer beyond the normal operating range than conventional off-line simulators, especially at early stages in development processes or during fault tests. Vessel's power system model is developed by using a MATLAB/SIMULINK software and by communicating between an OPAL-RT's OP5600 simulator. The PMS uses a Modbus communication protocol implemented using LabVIEW software. Representative tests of the PMS functions are performed to verify the validity of the proposed HIL-based test platform.

A Study on Linkage Integration Control System Using Power Line Communication(PLC) and Wireless Sensor Network(WSN) (전력선 통신과 무선 센서 네트워크 기술을 이용한 연동 통합제어 시스템에 관한 연구)

  • Ji, Yun-il;Lim, Kang-il;Park, Kyung-sub
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.733-736
    • /
    • 2009
  • Power Line Communication(PLC) is need not additional communication line. So establishment expense is inexpensive and application is simple. Therefore, lower part network of various application field is possible. However, there are high subordinate interference and noise problem on limited transmission data and communication interference element. Wireless Sensor Network(WSN) is need not infrastructure, Self-regulating network architecture of sensor nodes is possible. So at short time, network construction is available. But, power consumption is increased by active sensing for QoS elevation and unnecessary information transmission, low electric power design and necessity of improve protocol are refered to life shortening problem and is studied. In this paper, supplement problem of power line communication and wireless sensor network mutually and because advantage becomes linkage integration control system using synergy effect of two technologies as more restriction be and tries to approach structurally control network that is improved for smooth network environment construction. Honeywell's hybrid sensor network does comparative analysis(benchmarking). Confirm performance elevation proposing teaming of power line communication and wireless sensor network. Through simulation, service delay decreases and confirms that performance elevation.

  • PDF

A study on the receiving rate of the data of the hybrid communication system using data transfer methods for controller system of navigational aids (데이터 전송방식에 따른 항로표지 관리용 하이브리드 통신 시스템의 수신율 분석에 관한 연구)

  • Jeon, Joong Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.78-85
    • /
    • 2014
  • The Mu-communication board supported by hybrid communication is designed with Cortex M3, which is a low power energy consumption 32-bit microcontroller. The Cortex M3 microcontroller has UART(Universal asynchronous receiver/transmitter) ports which can set appropriately using the command line interpreter (CLI) program with each port. URAT ports are used for hybrid communication modems, GPS modules, etc. When the socket type was compared with the short message service type, the socket type was proven to be better. By improving the receiving performance in the control and management system of the AtoN, data loss was minimized. During the testing of the socket and SMS, data was collected from each buoy for 12 hours every 1 minute and the receiving rate of the data was found to be more than 98.58 % and 99.42 % respectively.

A Case Study of Virtual PLC Validation System’s Implementation : In Case of An Automobile Trim Line (가상 PLC 검증 시스템의 구현 사례 : 자동차 의장 라인의 예)

  • Bae, Seong-Hun;Kim, Yearn-Min
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • This study presents a system for validating the PLC code in the virtual environments of automobile trim line. There have been considerable efforts to develop standard PLC editors for saving human power and PLC test time. However, it was difficult to apply the PLC editor on a real shop floor environment. A virtual equipment was developed to communicate with the PLC module of a shop floor and to make up the connectivity environment by a special protocol. We can validate the code without launching real equipments because the PLC module and the virtual equipment is able to be controlled in real time by the OPC protocol. An experimental model is applied to the final assembly line of an automotive industry and validated by using DELMIA Automation. In conclusion, the system is valuable in the process of PLC codes validation and virtual equipments operation. This system would reduce the development time of the PLC codes and improve the productivity and the integrity of the PLC codes.

Implementation of QoS-awared MAC Protocol for Home Networks (홈 네트워크를 위한 QOS 보장형 매체접속제어 프로토콜의 구현)

  • 황원주
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.2
    • /
    • pp.228-238
    • /
    • 2003
  • We believe that existing wire solutions such as HomePNA2.0 using phone lines and HomePlug using power line and wireless solution such as HomeRF are the most promising solutions, because of its cost-effectiveness. However, MAC protocols of these solutions provide only Class of Service(CoS) using priority mechanism like HomePNA and HomePlug or consider only voice among real-time traffics like HomeRF. For these reasons, we perceive the needs of the new MAC protocol which is no new wire solution and provides guaranteed Quality of Service (QoS) for not only voice but also video and audio. In light of this, we present the design and software implementation of a new MAC protocol for Home Networks. Our evaluation results of software implementation verify that proposed MAC protocol can provide low delay, low loss, and low jitter to real-time traffic by reserving bandwidth.