• Title/Summary/Keyword: Power-Saving

Search Result 1,284, Processing Time 0.031 seconds

Temperature Maintenance of an ITO Nanoparticle Film Heater (ITO 나노입자 면상발열체의 온도유지에 대한 연구)

  • Yang, Kyungwhan;Cho, Kyoungah;Im, Kiju;Kim, Sangsig
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.171-173
    • /
    • 2016
  • In this study, we fabricate a high efficiency heater consisting of the indium tin oxide (ITO) nanoparticle (NP)-paste and polydimethylsiloxane (PDMS) and investigate the effect of PDMS on temperature maintenance of the heater through the comparison with the PDMS-free ITO film heater. Compared to the ITO film heater, the temperature of the PDMS/ITO film heater lasts 1.5 times longer. And the power consumption of the PDMS/ITO film heater is reduced by 35%, owing to the low thermal conductivity of the PDMS layer.

Photo-sintering of Silaver Nanoparticles using UV-LED

  • Lee, Jaehyeong;Kim, Minha;Kim, Donguk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.88.1-88.1
    • /
    • 2015
  • In recent printed electronics technology, Photo-Sintering, a technique for sintering materials using a light source, has attracted attention as an alternative to time-consuming high-temperature thermal processes. The key principle of this technique is the selective heating of a strongly absorbent thin film, while preventing the heating of the transparent substrate by the light source. Many recent studies have used a flash lamp as the light source, and investigated the material-dependent effect of the width or intensity of the pulsed light. However, the flash lamp for sintering is not suitable for industry yet, because of needing too high power to sinter for a large scale. In energy-saving and large-scale sintering, LED technologies would be very useful in the near future. In this work, we investigated a sintering process for silver nanoparticles using UV-LED array. Silver nanoparticles in ink were inkjet-printed on a $1{\times}1cm$ area of a PET film and photo-sintered by 365 nm UV-LED module. A sheet resistance value as low as $72.6m{\Omega}/sq$ (2.3 - 4.5 times that of bulk silver) was obtained from the UV-LED sintering at 300 mW/cm2 for 50 min.

  • PDF

A Study on Ocean Cultural Space developed on the Gadeokdo lighthouse 100th anniversary memorial (가덕도등대 100주년 기념관을 활용한 해양문화공간에 관한 연구)

  • Han, Chang-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.494-506
    • /
    • 2010
  • On the crisis of international economy, the government is making an effort to seek economic growing motivation with the method of overcoming economic crisis and 'low carbon green growth'. Furthermore, to promote maritime vessel traffic service related inefficient energy wastage was revealed and eco-friendly alternative energy was accepted because of high price of oil in the beginning of 2008. In this situation, I'm going to discuss the possibility of eco-friendly energy system in maritime vessel traffic service with the way of cutting the budget and expansion of solar power generation system which was promoted to meet governmental 'energy saving plan for high price of oil'.

  • PDF

The Development for Blending Brake System of Electrical Multiple Unit used by Electric Brake (전기제동을 이용한 전동차의 혼합제동장치의 개발방향)

  • Lee, Woo-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.155-157
    • /
    • 2008
  • An electric multiple unit(EMU) consists of car body, bogie and brake equipment which is directly related to safety and performance of the motorcar. The blending brake mixed an electric brake and a friction brake is to reduce the energy by applying the restoration energy caused when the motorcar is stopped to car lines and to curtail the maintenance cost by saving the friction brake use. We have developed the advanced EMU since 2004, based on the experiences on the standard EMU in 1999, and we develop the installation which minimizes the use rate of the friction air brake by maximizing the electric brake use in the existing blending brake. We could accomplish the goal by improving the motorcar's Performance and solving the restoration energy's deficit by the friction brake. Actually, when it comes to the test results of standard EMU, except the service brake, in most conditions, we use electric brake to meet the requirements of the necessary brake power, exclusive when the motorcar leaves and stops. Therefore, in this paper, we consider the design concept of motorcar's blending brakes and suggest the way to develop the blending brake using the electric brake maximumly, which is caused by adequately controling the electric brake and the restoration brake.

  • PDF

A Smart Home Prototype Implementation Using Raspberry Pi (라즈베리파이를 이용한 스마트 홈 프로토타입 구현)

  • Kim, Jeong-Won
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.10
    • /
    • pp.1139-1144
    • /
    • 2015
  • The internet of things(: IoT) which could produce new information as well as service through connecting small devices with internet interface becomes reality and could be utilized in home, office and plant. Especially the IoT can provide our home for safety, security, convenience, and power saving since all devices form a small internet. This paper proposes an IoT prototype for home with Raspberry Pi which has various sensors and monitors environment. This Raspberry Pi sensor node is small and inexpensive but can provide powerful service. The implemented node goes beyond simple role of sensor node and features a kind of sensor web node which performs various functions to outer network. So the proposed IoT prototype can provide flexibility as well as extensibility since it does not need expensive server.

A Case Study on the Quality Management of Construction Site through PDCA Cycle (PDCA Cycle적용을 통한 건설현장 품질관리에 관한 사례연구)

  • Baik, In-Whee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • According to the recent trends which are the diversity of customer requests and the multi-function of buildings, A construction company's business has converted from the producer-oriented approach to the consumer-oriented approach. Therefore, each construction company is continuously trying to improve the quality level as a way of corresponding to customer needs in these changing situations. The quality is one of the main management targets which judge the success of a project along with the schedule, the cost and the safety. As construction companies execute the quality management which they aimed at, it should be completed within the optimum schedule and the limit of the budget. Accordingly, the importance of the construction site management to complete a project is continuously increasing. The construction site management is the systematic method to perform the project goals such as the quality improvement, the cost saving and the safety management, which organically operate one another, by procuring the manpower, the material and the machine in the right time. Specially, as the construction industry has based on the construction site, the establish of systematic construction site management, which can effectively correspond sudden changes of the construction business environment, is essential to maximize the construction productivity. On top of that, the necessity of the quality management method is increasing to accommodate customer needs more spontaneously in the construction site. These endeavors could guarantee their competitive power.

A Study on the Optimal Design of Urban Energy Supply Systems (도시기반 에너지공급시스템의 최적화 방안 연구)

  • Kim, Yong-Ki;Lee, Tae-Won;Woo, Nam-Sub
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.396-402
    • /
    • 2009
  • Recently many efforts have been carried out on the development of energy-efficient and environment-friendly systems in order to preserve natural environment and to reduce environmental loads in the branch of the urban planning and the building design. In this study, a mathematical method was developed and a numerical analysis was carried out with various parameters to provide substantial data for optimal design and operation of urban energy supply systems. Components of the system and their specifications, such as a co-generation system and other heating and cooling systems, could be obtained through this analysis for various resource and energy requirements in urban area. In this study, the system constituents and operating characteristics, and their economic performances such as the value of objective function, the amount of energy consumption were discussed for various load patterns and power load ratios. Also, it turns out that the optimal energy supply system can save energy by $10{\sim}20%$ in comparison with the conventional energy supply system.

A Study on the Design Technique for Energy Performance Indicators of Existing Office Buildings (기존 오피스건물 에너지성능지표에 따른 설계기법 연구)

  • Jung, Hyungtae;Lee, You Na;Kim, Insoo;Ahn, Jong-Wook
    • Journal of Energy Engineering
    • /
    • v.27 no.3
    • /
    • pp.28-35
    • /
    • 2018
  • Guidelines and institutional support for buildings are being promoted around the world as measures for environmental pollution and energy conservation. In Korea, standards are prepared according to the energy saving design standards of new buildings as amended in 2013.09.01 and the zero energy building for new buildings mandatory process is being prepared from the recommendations. Nevertheless, the government's binding power on smaller buildings is insufficient. Energy savings were analyzed for the recently constructed office buildings (application of external insulation technique) and propose a dual envelope techniques were proposed for energy reduction.

Design of Sensor Network Security Model using Contract Net Protocol and DEVS Modeling (계약망 프로토콜과 DEVS 모델링을 통한 센서네트워크 보안 모델의 설계)

  • Hur, Suh Mahn;Seo, Hee Suk
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.4 no.4
    • /
    • pp.41-49
    • /
    • 2008
  • Sensor networks are often deployed in unattended environments, thus leaving these networks vulnerable to false data injection attacks in which an adversary injects forged reports into the network through compromised nodes. Such attacks by compromised sensors can cause not only false alarms but also the depletion of the finite amount of energy in a battery powered network. In order to reduce damage from these attacks, several security solutions have been proposed. Researchers have also proposed some techniques to increase the energy-efficiency of such security solutions. In this paper, we propose a CH(Cluster Header) selection algorithm to choose low power delivery method in sensor networks. The CNP(Contract Net Protocol), which is an approach to solve distribution problems, is applied to choose CHs for event sensing. As a result of employing CNP, the proposed method can prevent dropping of sensing reports with an insufficient number of message authentication codes during the forwarding process, and is efficient in terms of energy saving.

Biogas-Microturbine Distributed Generation Developement at Gong-Ju Public Livestock Wastewater Treatment Facility (공주 축산폐수공공처리장에서의 바이오가스-마이크로터빈 분산발전시스템 개발)

  • Park, Jung-Keuk;Hur, Kwang-Beom;Lee, Ki-Chul;Kang, Ho;Rhim, Sang-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.229-234
    • /
    • 2008
  • Korea Electric Power Corporation (KEPCO) has started the nation's first biogas-microturbine project in the city of Gongju as an effort to encourage the utilization of wasted biogas containing useful energy source in the form of $CH_4$. The goal of the project is to set up the biogas microturbine co-generation system for utilizing biogas as an energy source and improving the economics of the wastewater treatment plant. Wastewater treatment processes were investigated in depth to find improvement possibility. Changes in internal recirculation ratio and pre-treatment degree are needed to optimize plant operation and biogas production. Biogas pre-treatment system satisfies Capstone's fuel condition requirement with the test result of 99.9% and 90.2% of hydrogen sulphide and ammonia is removal performance. Installation of microturbine and manufacture of heat exchanger to warm anaerobic digester has been done successfully. Expected economic profit produced by the system is coming from energy saving including electricity 115,871kWh/year and heat contained in exhaust gas 579GJ/year.

  • PDF