• 제목/요약/키워드: Power zone

Search Result 817, Processing Time 0.03 seconds

Study on the Multi-Zone Furnace Analysis Method for Power Plant Boiler (발전용 보일러에 대한 다중영역분할 화로해석 기법의 활용성 연구)

  • Baek, SeHyun;kim, Donggyu;Lee, Jang Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.427-432
    • /
    • 2020
  • In this study, a multi-zone furnace analysis method that couples a 1D energy and mass balance calculation with a 3D radiative heat transfer calculation is tested in order to verify its reliability. The calculated results for a domestic 500 MW capacity coal-fired boiler furnace were compared with the design data of the boiler manufacturer and CFD analysis, and a good agreement was achieved. Although this calculation method is less sophisticated than the CFD furnace analysis, it has an advantage in terms of calculation time while being able to provide the furnace behavior according to the fuel characteristics and operational variable changes. Therefore, it is expected to be useful for boiler operation diagnosis and daily fuel/operation planning.

A Study for Improving the Power Factor of Distribution Transformer using Condenser Control Circuit (콘덴서 제어회로를 이용한 배전용 변압기의 역률 개선에 관한 연구)

  • Lee, Kwang-Jeek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.21-28
    • /
    • 2014
  • Daily use characteristics of apparent power supplied to distribution transformer can be separated into two different time zone of waking hours and sleeping hours. In sleeping hours, using amount of power is decreasing. The actual curve of power seemed to be quite similar to this kind of separation. Inserting a condenser into a circuit in each different time zone led to maximize power factor of the transformer. The compensating condenser's on/off time is controlled by hysteresis circuit utilizing op amp and power factor of the transformer was improved from 0.945 to 0.999. As a result, the average of current reduction was 2.53A per hour of transformer.

Characteristics of the Shaft Vibration in a High Head Pump-Turbine (고낙차 펌프-터빈에서의 축계 진동 특성)

  • Ha, Hyun-Cheon;Choi, Seong-Pil
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.2 s.3
    • /
    • pp.27-31
    • /
    • 1999
  • This paper describes the shaft vibration phenomena measured on a pump-turbine of a pumped storage power plant. The pump-turbine runs at a rotational speed of 450 rpm (7.5 Hz). The power output (load) of the pump-turbine is varied from 100 to 300 MW in the generating mode. The magnitude of the shaft vibration highly depends on the power load. The vibration magnitude of the shaft is very high in the middle load zone from 170 to 210 MW, elsewhere the vibration is low. From nitration spectra, it is shown that the frequency of major nitration in that load zone is 2.5 Hz which is approximately $34\%$ of the shaft rotating speed in Hz. This frequency component does not occur below and above that load zone. This subsynchronous vibration is caused by the flow induced disturbance due to spiral vortex flow downstream of the pump-turbine runner. Furthermore, the shaft vibration is highly decreased due to an increased bearing preload.

  • PDF

Characteristics of the Shaft Vibration in a High Head Pump-Turbine (고낙차 펌프-터빈에서의 축계 진동 특성)

  • Ha, Hyun Cheon;Choi, Seong Pil
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.166-172
    • /
    • 1998
  • This paper describes the shaft vibration phenomena measured on a pump-turbine ofa pumped storage power plant. The pump-turbine runs at a rotational speed of 450 rpm (7.5 Hz). The power output (load) of the pump-turbine was varied from 100 to 300 MW in the generating mode. It was found that the magnitude of the shaft vibration was highly dependent upon the power load. The vibration magnitude of the shaft vibration is very high in the middle load zone from 170 to 210 MW, elsewhere the vibration low. From vibration spectra, it was found that the frequency of major vibration in that load zone was 2.5 Hz which is approximately $34\%$ of the shaft rotating speed in Hz. This frequency component disappeared below and above that load zone. This subsynchronous vibration is caused by the flow induced disturbance due to spiral vortex flow downstream of the pump-turbine runner. Furthermore, it was found that shaft vibration was highly decreased due to the increase of bearing preload.

  • PDF

The Characteristics of Ductile Cast Iron Heat-treated by $CO_2$Laser (구상흑연주철의 $CO_2$레이저 표면경화 특성)

  • 정원기;전병철;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.998-1002
    • /
    • 1997
  • This study has been performed to predict beam absorption with analysis of temperature field by using a FEM in co /sab 2/ laser hardening and to invesrigate into some effects of power density and travel speed of laser beam on the microstructure and hardness of ductile cast iron treated by laser surface hardening technique. Optical micrograph has shown that large martensite and small amount of retained austenite appear in inside hardened zone. Hardness measurement has revealed that the range of maximum hardness value is Hv=415 .+-. 10. The power density increases and the travel speed decreases, the depth of hardened zone increases due to increase of input power density.

  • PDF

The Performance Assessment of a Straight-Type Five-Hole Pressure Probe Using a Zone Partition and Two-Dimensional Curve-Fitting Functions (영역분할과 2차원 커브피팅 함수들을 이용하는 직선형 5공 압력프로브의 성능 평가)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.22-31
    • /
    • 2014
  • This paper introduced the new calibration algorithm of a straight-type five-hole pressure probe necessary for calculating three-dimensional flow velocity components. The new velocity data reduction method using both a commercial two-dimensional curve-fitting program and the zone partition method of a calibration map was firstly introduced in this study. This new calibration method can be applied up to the wide flow angle of ${\pm}80^{\circ}$ despite of using a five-hole pressure probe because this data reduction method showed a comparatively good performance in calculating yaw and pitch angles from the calibration map.

Study on the Elliptical Elastohydrodynamic Lubrication in the Toroidal Continuously Variable Transmission (가변 동력전달 장치에서의 타원 형상 점접촉 탄성유체윤활 연구)

  • 장시열
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.310-315
    • /
    • 2001
  • The most general feature of contact zone among the mechanical components is elliptical circle. In particular, continuously variable transmission (CVT) of toroidal type has elliptical shape of contact zone under the elastohydrodynamic lubrication condition, where the power is transmitted by the shearing the efluid. Due to the traction of the shear behaviors of lubricant over the small elliptical contact zone, high power of torque is transmitted. During the power transmission, many kinds of mechanical movements occur such as squeezing, sliding, rolling and spinning. The spinning effect that is not common contact behavior in tribological components frequently makes significant abnormal wear damage. In this work, the analysis of elliptical contact of elastohydrodynamic lubrication with spin effect is performed, which will give very useful information to understand the traction behaviors in toroidal type of CVT system.

  • PDF

An Improved Zone-Based Routing Protocol for Heterogeneous Wireless Sensor Networks

  • Zhao, Liquan;Chen, Nan
    • Journal of Information Processing Systems
    • /
    • v.13 no.3
    • /
    • pp.500-517
    • /
    • 2017
  • In this paper, an improved zone-based routing protocol for heterogeneous wireless sensor networks is proposed. The proposed protocol has fixed the sized zone according to the distance from the base station and used a dynamic clustering technique for advanced nodes to select a cluster head with maximum residual energy to transmit the data. In addition, we select an optimal route with minimum energy consumption for normal nodes and conserve energy by state transition throughout data transmission. Simulation results indicated that the proposed protocol performed better than the other algorithm by reducing energy consumption and providing a longer network lifetime and better throughput of data packets.

Ecological Study of the Marine Algal Community at the Coast of Taean Thermal Power Plant, Korea (태안화력발전소 주변 해조군집의 생태 연구)

  • Yu, Jong-Su;Kim, Yeong-Hwan
    • ALGAE
    • /
    • v.18 no.4
    • /
    • pp.311-320
    • /
    • 2003
  • The community structure of benthic marine algae was investigated at Taean Thermal Power Plant and other places around Taean Peninsula, the west coast of Korea. Total of 100 species including 3 Cyanophyta, 14 Chlorophyta, 18 Phaeophyta, and 65 Rhodophyta were identified. The number of species was highest with 78 species at the Power Plant intake, followed by 61 at the discharge, 56 at Bunjeondo, and 50 at Maoe. It was noteworthy that a subtropical species Caulerpa okamurae was collected at the intake in autumn and it was the first observation in the west coast of Korea. The pattern of vertical algal distribution showed Gloiopeltis furcata occurred in the upper intertidal zone, Sargassum thunbergii and Corallina spp. in the middle and lower zone and Enteromorpha spp. in the lower middle zone. These were all dominant species except for Enteromopha spp., which was subdominant species. Other subdominant species were Chondrus ocellatus and Neorhodomela aculeata. The average diversity indices were between 0.70 and 1.20 at each area based on their dry weight. The similarity index was 0.79 between the algal flora of this study and that of 1987, indicating that the condition of the benthic environment remained unchanged since then. This area maintained its environmental quality, so the algal community remained same with similar structure. This study area seemed a suitable place for long term monitoring of the benthic environment where industrial facilities such as a power plant might affect the benthic algal community.

Characteristics of Surface Hardening by Laser Power Control in Real Time of Spheroidal Graphite Cast Iron (실시간 출력 제어를 통한 구상흑연 주철의 레이저 표면경화 특성)

  • Kim, Jongdo;Song, Mookeun
    • Laser Solutions
    • /
    • v.18 no.2
    • /
    • pp.1-4
    • /
    • 2015
  • This study is related to the surface hardening treatment to spheroidal graphite cast iron for die by using high power diode laser. Laser device used in this experiment is capable of real-time laser power control. This is because the infrared temperature sensor (two color pyrometer) attached to the optical system measures the surface temperature of specimen and adjusts the laser power in real time. The surface treatment was carried out with the change of heat treatment temperature at the beam travel speed 3 mm/sec. Hardened width and depth was measured and hardened zone was analyzed by micro vickers hardness test in order to research the optimum condition of heat treatment. The changes in microstructure of the hardened zone also was examined. As a result of hardness measurement and observations on microstructure of hardened zone, hardness increased over three times as compared with base metal because the martensite was formed on the matrix structure.