• 제목/요약/키워드: Power zone

검색결과 817건 처리시간 0.041초

몽골의 심부 지열에너지 자원과 지열발전에 관한 연구 (A Study on Deep Geothermal Energy and Potential of Geothermal Power Generation in Mongolia)

  • 한정상;윤운상;김영식;한찬;박유철;목종구
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권3호
    • /
    • pp.1-11
    • /
    • 2012
  • Mongolia has three(3) geothermal zones and eight(8) hydrogeothermal systems/regions that are, fold-fault platform/uplift zone, concave-largest subsidence zone, and mixed intermediate-transitional zone. Average temperature, heat flow, and geothermal gradient of hot springs in Arhangai located to fold-fault platform/uplift zone are $55.8^{\circ}C$, 60~110 mW/m2 and $35{\sim}50^{\circ}C/km$ respectively and those of Khentii situated in same zone are $80.5^{\circ}C$, 40~50 mW/m2, and $35{\sim}50^{\circ}C/km$ separately. Temperature of hydrothermal water at depth of 3,000 m is expected to be about $173{\sim}213^{\circ}C$ based on average geothermal gradient of $35{\sim}50^{\circ}C/km$. Among eight systems, Arhangai and Khentii located in A type hydrothermal system, Khovsgol in B type, Mongol Altai plateau in C type, and Over Arhangai in D type are the most feasible areas to develop geothermal power generation by Enhanced Geothermal System (EGS). Potential electric power generation by EGS is estimated about 2,760 kW at Tsenher, 1,752 kW at Tsagaan Sum, 2,928 kW at Khujir, 2,190 kW at Baga Shargaljuut, and 7,125 kW at Shargaljuut.

오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰 (Examination with Transmission Line Distance Relay Setting Rule Considering Error)

  • 조성진;최면송;현승호;김종욱;이주왕;조범섭;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

저 합금강재(2.25Cr-1.0Mo) 반복 보수용접 열영향부의 특성 (A Characteristics of the Multiple Repair Welding HAZs in a Low Alloy-Steel(2.25Cr-1.0Mo))

  • 이철구;안종석;이남혁;이길재
    • Journal of Welding and Joining
    • /
    • 제26권1호
    • /
    • pp.50-55
    • /
    • 2008
  • A low alloy-steel(2.25Cr-1.0Mo) has been widely used for boiler piping, header and tubes in high temperature and pressure conditions of the thermal power plant. It is common knowledge that the repair welding is permitted two or three times by customary practice rule, but there is no regulation to limit the number of repair welding base on the study heat-affected zone(HAZ), which is the weakest zone when repair welding is under taken, by experiments about the metallographic degradation and mechanical properties. Therefore, this study aims to verify the reliability of 5 times repair welding through conducting the experimental observation in the mechanical and the metallographic change on HAZ varying repair welding times. In results of the experiments, it is concluded that the reliability was kept in HAZ even up to the fifth repairs.

고속 무선 데이터 서비스를 위한 CDMA 순방향 링크에서의 Zone-based 전력제어 방식 (Zone-based Power Control Mechanism of CDMA Forward Link for High-speed Wireless Data Services)

  • 윤승윤;임재성
    • 한국통신학회논문지
    • /
    • 제27권7B호
    • /
    • pp.673-685
    • /
    • 2002
  • 본 논문에서는 먼저 음성과 데이터 트래픽의 혼합으로 해당 트래픽 채널간의 송/수신 전력 차이가 발생하게 되는 CDMA 순방향 링크 환경에 빠른 폐회로 전력제어 방식을 도입함으로써 발생하는 장단점을 분석하고, 시스템자원 할당 관점에서 기존의 빠른 전력제어 방식의 성능을 개선시킬 수 있는 Zone-based 전력제어 방식을 제안한다. 제안하는 Zone-based 전력제어 방식은 이동국의 위치 분포에 따라 데이터 트래픽의 전력과 전송률을 동시에 제어하는 메커니즘이다. 즉 제안하는 방식은 CDMA 시스템의 빠른 전력제어 방식에 기반을 두고 있으며 동시에 비실시간 데이터 트래픽의 전송률을 적응적으로 제어하여 전력 이득을 얻기 때문에 해당 채널에 소비되는 전력량 이득을 취할 수 있고 결과적으로는 간섭량 생성을 줄일 수 있는 방안이다. 제안하는 방식은 시스템에 유입되는 간섭량이 커지는 상황에서도 고속 트래픽의 서비스 영역을 셀의 전체 영역으로 확보해줌은 물론 저속 트래픽의 QoS도 지속적으로 유지해줄 수 있는 장점을 갖는다. 시뮬레이션을 통한 실험 결과들은 제안하는 방식이 기존 방식에 비하여 상당한 성능 개선이 있음을 보여주었다. 특별히 고속 데이터 트래픽의 수가 증가하는 상황에서 제안하는 전력제어 방식은 전력 소비량과 트래픽 처리율 관점에서 기존 전력제어 방식보다 훨씬 우수한 성능을 보였다.

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

MANET에서 Power-Aware를 고려한 2계층 Zone기반 라우팅 프로토콜(ZTPA) (A Zone-Based Two-Level Routing with Power-Aware (ZTPA) for MANETs)

  • 김소정;원수섭;박해웅;송주석
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2004년도 춘계학술발표대회
    • /
    • pp.1429-1432
    • /
    • 2004
  • MANET(Mobile Ad Hoc Network)이란 어떠한 기반 구조나 중앙의 관리없이 동적으로 임시 네트워크를 형성하는 무선 mobile node의 집합이다. 이 논문에서는 MANET에서 근원지 node가 목적지 node로의 route를 발견하기 위해 전체 네트워크를 대상으로 route request 패킷을 flooding 할 경우 결과적으로 네트워크의 성능을 저하시킨다는 점과 mobile node가 제한된 양의 power를 가지고 있다는 점에 초점을 맞추어 연구가 진행되었다. 다시 말해 이 논문에서 제안된 ZTPA 라우팅 프로토콜은 기존의 ZRP를 기본으로 서로 겹치지 않는 격자 모양의 zone으로 네트워크가 구성된다. 또한 proactive 라우팅이 이루어지는 IARP에서 route 설정시 현재 node에 남아있는 power를 고려한 CMMBCR 라우팅 프로토콜이 사용되며 이와 더불어 두 개의 임계치(SVSZ, FVSZ)를 사용함으로써 설정된 route의 수명을 연장하고 신뢰성 있는 데이터 전송이 가능하여 전체적인 네트워크의 성능 향상을 야기할 수 있다.

  • PDF

무선 Ad hoc 망의 새로운 Zone 기법을 적용한 AOZDV(Ad Hoc On-demand Zone and Distance-Vector) 라우팅 프로토콜 (AOZDV(Ad Hoc On-demand Zone and Distance-Vector) : A Routing Protocol with Novel Zone Mechanism in Wireless Ad hoc Networks)

  • 김용우;최성재;이홍기;송주석
    • 한국정보과학회논문지:정보통신
    • /
    • 제33권4호
    • /
    • pp.299-309
    • /
    • 2006
  • Ad hoc 환경에서 사용되는 On-demand 방식인 AODV 라우팅 프로토콜은 경로를 찾기 위하여 노드들이 가지고 있는 라우팅 테이블을 우선 검사하고, 만약 적합한 경로가 존재하지 않거나 유효하지 않은 경로, 또는 중간노드에서 경로손실이 발생하였을 경우 Route Discovery Process(RDP)를 수행하여 새로운 경로를 찾게 된다. 하지만 중 / 대형 Ad hoc 환경에서 이러한 RDP의 증가는 네트워크 성능의 저하를 초래한다. 본 논문에서는 경로설정을 위해 사용되는 AODV 라우팅 프로토콜에 Zone 개념을 도입한 AOZDV(Ad hoc On-demand Zone and Distance-Vector Routing Protocol)를 제안한다. AOZDV는 노드의 트래픽과 전력정보를 활용하여 소스 / 목적지 노드에 Zone을 형성하고, Zone 내부에서의 라우팅은 Destination-Vector Table을 활용하는 기법으로서, 시뮬레이션을 통해 AOZDV 가 기존의 라우팅 프로토콜들에 비해 노드들의 이동성으로 인해 발생하는 경로손실 및 RDP 가 감소함을 확인할 수 있었다.

Multi zone Modeling을 이용한 흡기관내의 과급이 온도성층화를 갖는 예혼합압축자기착화엔진에 미치는 영향에 관한 연구 (Effect of the Boost Pressure on Thermal Stratification on HCCI Engine Using Multi-Zone Modeling)

  • 권오석;임옥택
    • 대한기계학회논문집B
    • /
    • 제33권4호
    • /
    • pp.248-254
    • /
    • 2009
  • The HCCI engine is a next generation engine, with high efficiency and low emissions. The engine may be an alternative to SI and DI engines; however, a pressure rise rate is a major limitation for high load range and power reduction. Recently, we were able to reduce the pressure rise rate using thermal stratification. Nevertheless, this was insufficient to produce high power. In this study, the reduction of the pressure rise rate using thermal stratification was confirmed and the HCCI engine power was increased using the boost pressure. The rate and engine power were produced by CHEMKIN and modified SENKIN. As a result of increasing the boost pressure, a higher IMEP was attained while the pressure rise rate increased only slightly in the HCCI with thermal stratification.

강원도 해수욕장의 유영폭 및 해빈단면 축척계수 조사 분석 (A Survey and Analysis of Swim Zone Width and Beach Scale Factor for Gangwon Beaches)

  • 이정렬;김인호
    • 한국해안해양공학회지
    • /
    • 제18권3호
    • /
    • pp.241-250
    • /
    • 2006
  • 39개 동해 해수욕장에 대한 대표 입경과 유영폭, 포말대 경사 등을 조사하였다. 이 자료를 근거로 입경과 포말대 경사의 상관 관계를 살폈으며 해수욕장의 유영폭을 추정하는 데 있어 어떤 인자의 영향력이 더 큰가를 분석하였다. 분석 결과 대상 해수욕장에서는 유영폭과 대표입경의 상관성이 더 우월하며 유영폭이 대표입경의 1.15승에 반비례하는 결과를 얻을 수 있었다. 분석하는 데 있어 해빈 종단면 $h=Ay^{2/3}$ 식이 사용되었으며 해빈 종단면 축척 계수 A는 대표입경의 0.77승에 비례하는 것으로 분석되었다.

Preventing cascading failure of electric power protection systems in nuclear power plant

  • Moustafa, Moustafa Abdelrahman Mohamed Mohamed;Chang, Choong-koo
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.121-130
    • /
    • 2021
  • Cascading failure is the main cause of large blackouts in electrical power systems; this paper analyzes a cascading failure in Hanbit nuclear power plant unit two (2) caused by a circuit breaker (CB) operation failure. This malfunction has been expanded to the loss of offsite power (LOOP). In this study, current practices are reviewed and then the methodologies of how to prevent cascading failures in protection power systems are introduced. An overview on the implementation of IEC61850 GOOSE messaging-based zone selective interlocking (ZSI) scheme as key solution is proposed. In consideration of ZSI blocking time, all influencing factors such as circuit breaker opening time, relay I/O response time and messages travelling time in the communication network should be taken into account. The purpose of this paper is to elaborate on the effect of cascading failure in NPP electrical power protection system and propose preventive actions for this failures. Finally, the expected advantages and challenges are elaborated.