• Title/Summary/Keyword: Power supply system

Search Result 3,255, Processing Time 0.025 seconds

Noise-robust electrocardiogram R-peak detection with adaptive filter and variable threshold (적응형 필터와 가변 임계값을 적용하여 잡음에 강인한 심전도 R-피크 검출)

  • Rahman, MD Saifur;Choi, Chul-Hyung;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.126-134
    • /
    • 2017
  • There have been numerous studies on extracting the R-peak from electrocardiogram (ECG) signals. However, most of the detection methods are complicated to implement in a real-time portable electrocardiograph device and have the disadvantage of requiring a large amount of calculations. R-peak detection requires pre-processing and post-processing related to baseline drift and the removal of noise from the commercial power supply for ECG data. An adaptive filter technique is widely used for R-peak detection, but the R-peak value cannot be detected when the input is lower than a threshold value. Moreover, there is a problem in detecting the P-peak and T-peak values due to the derivation of an erroneous threshold value as a result of noise. We propose a robust R-peak detection algorithm with low complexity and simple computation to solve these problems. The proposed scheme removes the baseline drift in ECG signals using an adaptive filter to solve the problems involved in threshold extraction. We also propose a technique to extract the appropriate threshold value automatically using the minimum and maximum values of the filtered ECG signal. To detect the R-peak from the ECG signal, we propose a threshold neighborhood search technique. Through experiments, we confirmed the improvement of the R-peak detection accuracy of the proposed method and achieved a detection speed that is suitable for a mobile system by reducing the amount of calculation. The experimental results show that the heart rate detection accuracy and sensitivity were very high (about 100%).

Ecological Role of Urban Stream and Its Improvement (도시하천의 생태학적 역할과 개선방안)

  • Son, Myoung-Won
    • Journal of the Korean association of regional geographers
    • /
    • v.4 no.1
    • /
    • pp.15-25
    • /
    • 1998
  • A stream plays an important role as the source of drinking water, the ecological space and the living space. But the today's urban stream whose ecosystem is destroyed and water quality become worse in consequence of covering, concrete dyke construction, and the adjustment of high-water-ground[dunchi], is deprived of the function as a stream. Therefore this paper aims to elucidate the role that urban stream plays ecologically and to try to find a improvement to the problem. A stream is the pathway through which several types of the solar radiation energy are transmitted and the place which is always full of life energy. In the periphery of a stream, primary productivity is high and carrying capacity of population is great. Thus ancient cities based on agricultural products grew out of the fertile surroundings of stream. In Korea most cities of the Chosen Dynasty Period based on the agriculture have grown out of the erosional basins where solar energy is concentrated. The role of a stream in this agricultural system is the source of energy and material(water and sediment) and a lifeline. In consequence of the growth of cities and the rapid growing demands of water supply after the Industrial Revolution, a stream has become a more important locational factor of city. However, because cities need the life energy of urban streams no longer, urban streams cannot play role as a lifeline. And As pollutant waste water has poured into urban streams after using external streams' water, urban streams have degraded to the status of a ditch. As the results of the progress of urbanization, the dangerousness of inundation of urban stream increased and its water quality became worse. For the sake of holding back it, local governments constructed concrete dyke, adjusted high-water-ground[dunchi], and covered the channel. But stream ecosystem went to ruin and its water quality became much worse after channelization. These problems of urban stream can be solved by transmitting much energy contained in stream to land ecosystem as like rural stream. We should dissipate most of the energy contained in urban stream by cultivating wetland vegetation from the shore of stream to high-water-ground, and should recover a primitive natural vigorous power by preparation of ecological park.

  • PDF

A 13b 100MS/s 0.70㎟ 45nm CMOS ADC for IF-Domain Signal Processing Systems (IF 대역 신호처리 시스템 응용을 위한 13비트 100MS/s 0.70㎟ 45nm CMOS ADC)

  • Park, Jun-Sang;An, Tai-Ji;Ahn, Gil-Cho;Lee, Mun-Kyo;Go, Min-Ho;Lee, Seung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.46-55
    • /
    • 2016
  • This work proposes a 13b 100MS/s 45nm CMOS ADC with a high dynamic performance for IF-domain high-speed signal processing systems based on a four-step pipeline architecture to optimize operating specifications. The SHA employs a wideband high-speed sampling network properly to process high-frequency input signals exceeding a sampling frequency. The SHA and MDACs adopt a two-stage amplifier with a gain-boosting technique to obtain the required high DC gain and the wide signal-swing range, while the amplifier and bias circuits use the same unit-size devices repeatedly to minimize device mismatch. Furthermore, a separate analog power supply voltage for on-chip current and voltage references minimizes performance degradation caused by the undesired noise and interference from adjacent functional blocks during high-speed operation. The proposed ADC occupies an active die area of $0.70mm^2$, based on various process-insensitive layout techniques to minimize the physical process imperfection effects. The prototype ADC in a 45nm CMOS demonstrates a measured DNL and INL within 0.77LSB and 1.57LSB, with a maximum SNDR and SFDR of 64.2dB and 78.4dB at 100MS/s, respectively. The ADC is implemented with long-channel devices rather than minimum channel-length devices available in this CMOS technology to process a wide input range of $2.0V_{PP}$ for the required system and to obtain a high dynamic performance at IF-domain input signal bands. The ADC consumes 425.0mW with a single analog voltage of 2.5V and two digital voltages of 2.5V and 1.1V.

Performance of a Molten Carbonate Fuel Cell With Direct Internal Reforming of Methanol (메탄올 내부개질형 용융탄산염 연료전지의 성능)

  • Ha, Myeong Ju;Yoon, Sung Pil;Han, Jonghee;Lim, Tae-Hoon;Kim, Woo Sik;Nam, Suk Woo
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.329-335
    • /
    • 2020
  • Methanol synthesized from renewable hydrogen and captured CO2 has recently attracted great interest as a sustainable energy carrier for large-scale renewable energy storage. In this study, molten carbonate fuel cell's performance was investigated with the direct conversion of methanol into syngas inside the anode chamber of the cell. The internal reforming of methanol may significantly improve system efficiency since the heat generated from the electrochemical reaction can be used directly for the endothermic reforming reaction. The porous Ni-10 wt%Cr anode was sufficient for the methanol steam reforming reaction under the fuel cell operating condition. The direct supply of methanol into the anode chamber resulted in somewhat lower cell performance, especially at high current density. Recycling of the product gas into the anode gas inlet significantly improved the cell performance. The analysis based on material balance revealed that, with increasing current density and gas recycling ratio, the methanol steam reforming reaction rate likewise increased. A methanol conversion more significant than 90% was achieved with gas recycling. The results showed the feasibility of electricity and syngas co-production using the molten carbonate fuel cell. Further research is needed to optimize the fuel cell operating conditions for simultaneous production of electricity and syngas, considering both material and energy balances in the fuel cell.

A Study for Improvement of Nursing Service Administration (병원 간호행정 개선을 위한 연구)

  • 박정호
    • Journal of Korean Academy of Nursing
    • /
    • v.3 no.1
    • /
    • pp.13-40
    • /
    • 1972
  • Much has teed changed in the field of hospital administration in the It wake of the rapid development of sciences, techniques ana systematic hospital management. However, we still have a long way to go in organization, in the quality of hospital employees and hospital equipment and facilities, and in financial support in order to achieve proper hospital management. The above factors greatly effect the ability of hospitals to fulfill their obligation in patient care and nursing services. The purpose of this study is to determine the optimal methods of standardization and quality nursing so as to improve present nursing services through investigations and analyses of various problems concerning nursing administration. This study has been undertaken during the six month period from October 1971 to March 1972. The 41 comprehensive hospitals have been selected iron amongst the 139 in the whole country. These have been categorized according-to the specific purposes of their establishment, such as 7 university hospitals, 18 national or public hospitals, 12 religious hospitals and 4 enterprise ones. The following conclusions have been acquired thus far from information obtained through interviews with nursing directors who are in charge of the nursing administration in each hospital, and further investigations concerning the purposes of establishment, the organization, personnel arrangements, working conditions, practices of service, and budgets of the nursing service department. 1. The nursing administration along with its activities in this country has been uncritical1y adopted from that of the developed countries. It is necessary for us to re-establish a new medical and nursing system which is adequate for our social environments through continuous study and research. 2. The survey shows that the 7 university hospitals were chiefly concerned with education, medical care and research; the 18 national or public hospitals with medical care, public health and charity work; the 2 religious hospitals with medical care, charity and missionary works; and the 4 enterprise hospitals with public health, medical care and charity works. In general, the main purposes of the hospitals were those of charity organizations in the pursuit of medical care, education and public benefits. 3. The survey shows that in general hospital facilities rate 64 per cent and medical care 60 per-cent against a 100 per cent optimum basis in accordance with the medical treatment law and approved criteria for training hospitals. In these respects, university hospitals have achieved the highest standards, followed by religious ones, enterprise ones, and national or public ones in that order. 4. The ages of nursing directors range from 30 to 50. The level of education achieved by most of the directors is that of graduation from a nursing technical high school and a three year nursing junior college; a very few have graduated from college or have taken graduate courses. 5. As for the career tenure of nurses in the hospitals: one-third of the nurses, or 38 per cent, have worked less than one year; those in the category of one year to two represent 24 pet cent. This means that a total of 62 per cent of the career nurses have been practicing their profession for less than two years. Career nurses with over 5 years experience number only 16 per cent: therefore the efficiency of nursing services has been rated very low. 6. As for the standard of education of the nurses: 62 per cent of them have taken a three year course of nursing in junior colleges, and 22 per cent in nursing technical high schools. College graduate nurses come up to only 15 per cent; and those with graduate course only 0.4 per cent. This indicates that most of the nurses are front nursing technical high schools and three year nursing junior colleges. Accordingly, it is advisable that nursing services be divided according to their functions, such as professional, technical nurses and nurse's aides. 7. The survey also shows that the purpose of nursing service administration in the hospitals has been regulated in writing in 74 per cent of the hospitals and not regulated in writing in 26 per cent of the hospitals. The general purposes of nursing are as follows: patient care, assistance in medical care and education. The main purpose of these nursing services is to establish proper operational and personnel management which focus on in-service education. 8. The nursing service departments belong to the medical departments in almost 60 per cent of the hospitals. Even though the nursing service department is formally separated, about 24 per cent of the hospitals regard it as a functional unit in the medical department. Only 5 per cent of the hospitals keep the department as a separate one. To the contrary, approximately 12 per cent of the hospitals have not established a nursing service department at all but surbodinate it to the other department. In this respect, it is required that a new hospital organization be made to acknowledge the independent function of the nursing department. In 76 per cent of the hospitals they have advisory committees under the nursing department, such as a dormitory self·regulating committee, an in-service education committee and a nursing procedure and policy committee. 9. Personnel arrangement and working conditions of nurses 1) The ratio of nurses to patients is as follows: In university hospitals, 1 to 2.9 for hospitalized patients and 1 to 4.0 for out-patients; in religious hospitals, 1 to 2.3 for hospitalized patients and 1 to 5.4 for out-patients. Grouped together this indicates that one nurse covers 2.2 hospitalized patients and 4.3 out-patients on a daily basis. The current medical treatment law stipulates that one nurse should care for 2.5 hospitalized patients or 30.0 out-patients. Therefore the statistics indicate that nursing services are being peformed with an insufficient number of nurses to cover out-patients. The current law concerns the minimum number of nurses and disregards the required number of nurses for operation rooms, recovery rooms, delivery rooms, new-born baby rooms, central supply rooms and emergency rooms. Accordingly, tile medical treatment law has been requested to be amended. 2) The ratio of doctors to nurses: In university hospitals, the ratio is 1 to 1.1; in national of public hospitals, 1 to 0.8; in religious hospitals 1 to 0.5; and in private hospitals 1 to 0.7. The average ratio is 1 to 0.8; generally the ideal ratio is 3 to 1. Since the number of doctors working in hospitals has been recently increasing, the nursing services have consequently teen overloaded, sacrificing the services to the patients. 3) The ratio of nurses to clerical staff is 1 to 0.4. However, the ideal ratio is 5 to 1, that is, 1 to 0.2. This means that clerical personnel far outnumber the nursing staff. 4) The ratio of nurses to nurse's-aides; The average 2.5 to 1 indicates that most of the nursing service are delegated to nurse's-aides owing to the shortage of registered nurses. This is the main cause of the deterioration in the quality of nursing services. It is a real problem in the guest for better nursing services that certain hospitals employ a disproportionate number of nurse's-aides in order to meet financial requirements. 5) As for the working conditions, most of hospitals employ a three-shift day with 8 hours of duty each. However, certain hospitals still use two shifts a day. 6) As for the working environment, most of the hospitals lack welfare and hygienic facilities. 7) The salary basis is the highest in the private university hospitals, with enterprise hospitals next and religious hospitals and national or public ones lowest. 8) Method of employment is made through paper screening, and further that the appointment of nurses is conditional upon the favorable opinion of the nursing directors. 9) The unemployment ratio for one year in 1971 averaged 29 per cent. The reasons for unemployment indicate that the highest is because of marriage up to 40 per cent, and next is because of overseas employment. This high unemployment ratio further causes the deterioration of efficiency in nursing services and supplementary activities. The hospital authorities concerned should take this matter into a jeep consideration in order to reduce unemployment. 10) The importance of in-service education is well recognized and established. 1% has been noted that on the-job nurses. training has been most active, with nursing directors taking charge of the orientation programs of newly employed nurses. However, it is most necessary that a comprehensive study be made of instructors, contents and methods of education with a separate section for in-service education. 10. Nursing services'activities 1) Division of services and job descriptions are urgently required. 81 per rent of the hospitals keep written regulations of services in accordance with nursing service manuals. 19 per cent of the hospitals do not keep written regulations. Most of hospitals delegate to the nursing directors or certain supervisors the power of stipulating service regulations. In 21 per cent of the total hospitals they have policy committees, standardization committees and advisory committees to proceed with the stipulation of regulations. 2) Approximately 81 per cent of the hospitals have service channels in which directors, supervisors, head nurses and staff nurses perform their appropriate services according to the service plans and make up the service reports. In approximately 19 per cent of the hospitals the staff perform their nursing services without utilizing the above channels. 3) In the performance of nursing services, a ward manual is considered the most important one to be utilized in about 32 percent of hospitals. 25 per cent of hospitals indicate they use a kardex; 17 per cent use ward-rounding, and others take advantage of work sheets or coordination with other departments through conferences. 4) In about 78 per cent of hospitals they have records which indicate the status of personnel, and in 22 per cent they have not. 5) It has been advised that morale among nurses may be increased, ensuring more efficient services, by their being able to exchange opinions and views with each other. 6) The satisfactory performance of nursing services rely on the following factors to the degree indicated: approximately 32 per cent to the systematic nursing activities and services; 27 per cent to the head nurses ability for nursing diagnosis; 22 per cent to an effective supervisory system; 16 per cent to the hospital facilities and proper supply, and 3 per cent to effective in·service education. This means that nurses, supervisors, head nurses and directors play the most important roles in the performance of nursing services. 11. About 87 per cent of the hospitals do not have separate budgets for their nursing departments, and only 13 per cent of the hospitals have separate budgets. It is recommended that the planning and execution of the nursing administration be delegated to the pertinent administrators in order to bring about improved proved performances and activities in nursing services.

  • PDF