• Title/Summary/Keyword: Power resource

Search Result 1,530, Processing Time 0.033 seconds

A Study on Momentary Voltage Variations and Fault Analysis in the Power Distribution System with Congeration Facilities (COGN). (열병합발전설비가 연계된 배전계통 순시전압변동 및 사고해석에 관한 연구)

  • Jung, Seong-Kyo;Choi, Joon-Ho;Kim, Dae-Won;Kim, Jae-Chul;Son, Hag-Sig;Kim, Yun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1192-1194
    • /
    • 1999
  • Recently, there has been growing interest in utilizing cogeneration(COGN) system which has high energy efficiency due to the lacking of energy resource, but insertion of cogeneration system into existing power distribution system can cause several problems such as voltage variations, reenergizing of feeder isolated by fault, increasing fault current because of reverse power of COGN. Also these problems increase the complexity of control, protection, and maintenance of power distribution systems. Hence, some problems according to COGN interconnection operation to power distribution system must be taken into account so that operation and security of power distribution system is not disturbed. This paper deals with momentary voltage variations and fault analysis caused by interconnection operation of COGN.

  • PDF

A Study on the Auxiliary Power Generator for Urban Photovoltaic/Wind Hybrid System (도시형 태양광/풍력 복합발전의 보조 전력발생장치 개발에 대한 연구)

  • Park, Se-Jun;Yun, Jeong-Phil;Yoon, Pil-Hyun;Ji, Woon-Seok;Lim, Jung-Yeol;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.187-191
    • /
    • 2004
  • Photovoltaic and wind power generation have an advantage of unpolluted and unlimited amount of energy resource. Since there is such an advantage in these energies, But photovoltaic system and wind system cannot always generate stable output with ever-changing weather condition. In this paper, the auxiliary power generator for hybrid system(photovoltaic 500[W], wind power generation 400[W]) was suggested. the auxiliary power generator that uses elastic energy of spiral spring to photovoltaic system was also added for present system. when output of photovoltaic system gets lower than 24[V], power was continuously supplied to load through the inverter by charging energy of spiral spring operates in DC generator.

  • PDF

Transmit Power Allocation for Soft Frequency Reuse in Coordinated Cellular Systems (인접셀간 협력하는 셀룰라 시스템에서 소프트 주차수 재사용을 위한 송신전력할당 기법)

  • Kim, Dong-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.4A
    • /
    • pp.316-323
    • /
    • 2009
  • Power allocation of soft frequency reuse(SFR) to increase cell edge user throughput by reducing inter-cell interference is proposed for coordinated cellular systems. SFR is the effective technique to increase cell edge user throughput, however, it costs the degradation of total system throughput. The cost increases when SFR operated in distributed resource controlled systems fails to be fast adaptive in the change of user distribution. The proposed scheme enables coordinated cells to control transmit power adaptively depending on user distribution so that it minimizes the loss of system throughput introduced from SFR while it guarantees enhancement of cell edge user throughput. Through system level simulation considering neighboring two cells, evaluation result for adaptive power allocation is shown compared with static power allocation.

Power Control of Synchronous Machine Type Wind Power System Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 동기기형 풍력 발전 시스템의 출력제어)

  • Han, Sang-Geun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.201-203
    • /
    • 2002
  • In recent years there has been a growing interest in renewable energy systems due to the environmental problem and the economic benefits of fuel savings. Such systems are usually connected to the existing power grid for "fuel displacement" purpose as well as of earning some "capacity credit". Wind power generation system(WPGS) is one of the most useful energy resource using natural environment. So far, it was very difficult to simulate the dispersed generation system including WPGS using EMTP or EMTDC because the source of the dispersed generation system has a particular wind power characteristic equation. In this paper, a novel simulation method of WPGS has proposed and a new wind turbine component for EMTDC is also developed. The wind power characteristic equation of wind turbine is used in order to realize the WPGS in EMTDC simulation. And the real field data of weather conditions is interfaced to EMTDC using Fortran program interface method. Consequently the simulation of WPGS using field data is realized in this paper and shows acceptable results.

  • PDF

A High-Level Data Path Allocation Algorithm for Low Power Architecture (저 전력 아키텍처를 위한 상위 레벨 데이터 패스 할당 알고리즘)

  • Lin, Chi-Ho
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.166-171
    • /
    • 2003
  • In this paper, we propose a minimal power data path allocation algorithm for low power circuit design. The proposed algorithm minimizes switching activity for input variables in scheduled CDFG. Allocations are further divided into the tasks of register allocation and module allocation. The register allocation algorithm execute that it eliminate spurious switching activity in functional unit and minimize the numbers of multiplexer. Also, resource allocation method selects a sequence of operations for a module such that the switching activity is reduced. Therefore, the algorithm executes to minimize the switching activity of input values, sequence of operations and number of multiplexer. Experimental results using benchmarks show that power is reduction effect from 13% to 17% power consumption, when compared with the Genesis-lp high-level synthesis system.

  • PDF

A study on wireless power generation for marine information acquisition using EAP actuator (EAP 액추에이터를 이용한 해양 정보 취득용 무선 전원 발생에 관한 연구)

  • Jeong, Eun-A;Lee, Kee-Yoon;Jeong, Hwang-Hun;Yun, So-Nam
    • Journal of Power System Engineering
    • /
    • v.15 no.5
    • /
    • pp.49-53
    • /
    • 2011
  • This study concerns about wireless power generation that uses the energy harvester with EAP actuator. The UWSN(Underwater Wireless Sensor Network) has been considered many times by many researches. Because the information of underwater is getting important to secure the resource or to predict the meteorological phenomena. But the sensor node in the UWSN is driven by the acoustic wave to communicate with other sensor node. And this acoustic wave usually spends a 100 times energy than the RF(Radio Frequency) wave due to transfermation medium(sea water). Therefore the power source of the sensor node is very important that is needed to improve in the UWSN. For this purpose, the energy harvester is made by the acrylic elastomer in this study. And the electrode is modified with an aluminum impurity to improve the efficiency of energy harvester. After that, the modified energy harvester is experimented to confirm the improvement of the energy efficiency.

Design of CIM(Common Information Model) Profile for Smart City Energy Monitoring (스마트시티 에너지 감시를 위한 CIM(Common Information Model) 프로파일 설계)

  • Youngil, Kim;Changhun, Chae;Yeri, Kim;Jihoon, Lee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.127-135
    • /
    • 2022
  • With the advent of high technologies such as the 4th Industrial Revolution and artificial intelligence and big data, efforts are being made to solve urban problems and improve the quality of life by applying new technologies in the smart city field. In addition, as carbon neutrality has emerged as an important issue due to global warming, smart city energy platform technologies such as urban energy management, efficiency improvement, and carbon reduction are in the spotlight. In order to effectively manage urban energy, energy resource information such as electricity, water, gas, hot water, heating, etc. must be collected from the management system of various energy utilities and managed on the central platform. The centrally integrated data is delivered to external city management systems that require city energy information through an energy platform. This study developed a CIM profile for smart city energy monitoring required to provide energy data to external systems. Electric data model were designed using the CIM class of IEC 61970, and water, gas, and heat data model were designed in compliance with the UML-based design ideas of IEC 61970.

Development of a Numerical Analysis Model for Heating and Power Generation System Combining a Cattle Manure Solid Fuel Combustion Boiler and the Organic Rankine Cycle (우분 고체연료 연소 보일러와 유기랭킨사이클을 결합한 난방 및 발전 시스템의 수치해석 모델 개발)

  • Donghwan Shin;Hyeongwon Lee;Hoon Jung;Joonyoung Choi;Jongyoung Jo
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.61-71
    • /
    • 2023
  • The necessity of energy utilization using livestock manure has been proposed with the decrease in domestic agricultural land. Livestock manure solid fuel has been investigated as a promising energy resource owing to its convenient storage and use in agricultural and livestock fields. Additional electricity production is possible through the integration of a biomass combustion boiler with the organic Rankine cycle (ORC). In this study, a mathematical system model of the cattle manure solid fuel boiler integrated with the ORC was developed to analyze the components' performance under variable operating conditions. A sensitivity analysis was conducted to confirm the electrical efficiency of the ORC turbine and the applicability of this system. The minimum required waste heat recovery rate was derived considering the system marginal price and levelized cost of electricity of the ORC. The simulation results showed that, in Korea, more than 77.98% of waste heat recovery and utilization in ORC turbines is required to achieve economic feasibility through ORC application.

Increasing Effect Analysis of the Wind Power Limit Using Energy Storage System in Jeju-Korea (에너지저장장치를 이용한 제주지역 풍력발전 한계용량 증대효과 분석)

  • Kim, Yeong-Hwan;Kim, Se-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.81-90
    • /
    • 2014
  • The Jeju-Korea power system is a small-sized network with a system demand ranging from a autumn minimum of 350MW to a summer peak of 716MW. Because Jeju island is well exposed to north-east winds with high speed, applications to connect to Jeju power system are flooded. Considering physical/environmental constraints, Jeju Self-governing Province has also target for the wind power capacity of 1,350MW by 2020. It amounts to two or three times of Jeju average-demand power and wind power limit capacity announced by Korea Power Exchange (KPX) company. Wind farm connection agreements will be signed to maximize utilization of wind resource. In spite of submarine cable HVDC connected to Korea mainland, Jeju power system is independently operated by frequency and reserve control. This study reevaluates wind power limit based on the KPX criteria from 2016 to 2020. First of all wind power generation limit are affected by off-peak demand in Jeju power system. Also the possibility capacity rate of charging wind power output is evaluated by using energy storage system (ESS). As a result, in case of using 110MWh ESS, wind power limit increases 33~55MW(30~50% of ESS), wind power constraint energy decreases from 68,539MWh to 50,301MWh and wind farm capacity factor increases from 25.9 to 26.1% in 2020.

Analysis on the Effects of Interference Mitigation for Ultra-wideband Coexistence with BWA

  • Yoon Young-Keun;Jin Hong-Heon;Choi Ik-Guen
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.2
    • /
    • pp.117-122
    • /
    • 2006
  • This paper presents the impacts of Ultra-wideband(UWB) applied in the communication applications using frequency band from 3.1 GHz to 10.6 GHz on Broadband Wireless Access(BWA) based on orthogonal frequency division multiplexing(OFDM) using frequency band of 3.5 GHz. It proposes low duty cycle(LDC) for enabling UWB to mitigate strong interference to BWA. The effects of interference mitigation are evaluated and analyzed in the environment of UWB coexistence with BWA. UWB with LDC scheme will be given to bring higher transmit power level corresponding to Federal Communications Commission(FCC) provisional limit for enabling UWB operation at 3.5 GHz bands.