• Title/Summary/Keyword: Power plane

Search Result 942, Processing Time 0.028 seconds

Field Application of a Latent Heat Storage Tank for Load Shaving of Domestic Hot Water Supply in District Heating (지역난방 급탕공급 부하균등화를 위한 잠열축열조의 현장 적용)

  • Park, Sung Yong;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.2
    • /
    • pp.42-47
    • /
    • 2021
  • In terms of district heating operation, efficient production and supply of heat by alleviating the peak load at a specific time require an application technology that can solve the inconvenience of the user and the difficulties of the supplier. In this study, a 78 ℃ class PCM heat storage tank suitable among the technologies that can solve these problems was manufactured and applied to the hot water supply facility for apartments in district heating users. As a result of the application of this system, it was confirmed that the supply temperature was constant to the user compared to the existing supply method. In addition, it was confirmed that the reduction of the peak load due to load equalization reduced the heat supply margin of 10% in the existing heat supply facility. And the construction cost of the new heat supply facility and the construction cost of heat users is decreased by 5% and 10%, respectively.

A Study on High performance Electrical Precipitation Technology for PM Removal in Exhaust Gas (배가스 내 미세먼지 제거를 위한 고성능 집진 기술에 대한 연구)

  • Kim, Soyeon;Kim, Minsung;Choi, Sangmi;Jung, Minkyu;Lee, Jinwook
    • Plant Journal
    • /
    • v.18 no.1
    • /
    • pp.50-54
    • /
    • 2022
  • The demand for high-efficiency dust collectors is rapidly increasing to remove PM from exhaust gas emission facilities, such as thermal power plants, steel mills, and industrial cogeneration plants, as the Pmemission standards have been strengthened. In this study, the electrospray is adapted for existing electrosratic precipitator(EP) to remedy its shortcomings and to improve the performance. Electrospray has been mainly used for the purpose of generating very fine droplets, but fir the purpose of EP, the flow rate over 10 mL/min per nozzleis required, and a high flow rate condition of 65 to 200 times is required. The electrospray of high flow rate has a completely different spray shape from the low flow rate condition, and was visualized through various figures such as corona discharge photographs and shadow images.

  • PDF

A study on the calculation of carbon credit according to the supply temperature of cogeneration (열병합발전 공급온도에 따른 탄소 배출권 산정 연구)

  • Choi, SangMi;Kim, Minsung;Kim, Soyeon;Lim, JiHun;Jeong, SangHun
    • Plant Journal
    • /
    • v.18 no.2
    • /
    • pp.46-51
    • /
    • 2022
  • As GHG reduction becomes a major global issue, the importance and interest of ETS is increasing. Korea experienced positive effects of the system since the introduction of ETS in 2015, but also faced various problems. The focus of this study is on the issue of applying the ETS system to the group energy of industrial complexes. The group energy of industrial complexes is a unique industrial form of Korea that cannot be found in the world. Therefore, if the system is implemented in the same way as the preceding countries, it will inevitably cause problems. In particular, the group energy of industrial complexes has the characteristic that the conditions and amount of heat supplied are dtermined according to the demands of customers and the amount of power generation is determined accordingly. We investigated how differenct temperatures of heat produced in cogeneration affect carbon credit calculations.

  • PDF

Flexural bearing capacity and stiffness research on CFRP sheet strengthened existing reinforced concrete poles with corroded connectors

  • Chen, Zongping;Song, Chunmei;Li, Shengxin;Zhou, Ji
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.1
    • /
    • pp.29-42
    • /
    • 2022
  • In mountainous areas of China, concrete poles with connectors are widely employed in power transmission due to its convenience of manufacture and transportation. The bearing capacity of the poles must have degenerated over time, and most of the steel connectors have been corroded. Carbon fiber reinforced polymer (CFRP) offers a durable, light-weight alternative in strengthening those poles that have served for many years. In this paper, the bearing capacity and failure mechanism of CFRP sheet strengthened existing reinforced concrete poles with corrosion steel connectors were investigated. Four poles were selected to conduct flexural capacity test. Two poles were strengthened by single-layer longitudinal CFRP sheet, one pole was strengthened by double-layer longitudinal CFRP sheets and the last specimen was not strengthened. Results indicate that the failure is mainly bond failure between concrete and the external CFRP sheet, and the specimens fail in a brittle pattern. The cross-sectional strains of specimens approximately follow the plane section assumption in the early stage of loading, but the strain in the tensile zone no longer conforms to this assumption when the load approaches the failure load. Also, bearing capacity and stiffness of the strengthened specimens are much larger than those without CFRP sheet. The bearing capacity, initial stiffness and elastic-plastic stiffness of specimen strengthened by double-layer CFRP are larger than those strengthened by single-layer CFRP. Weighting the cost-effective effect, it is more economical and reasonable to strengthen with single-layer CFRP sheet. The results can provide a reference to the same type of poles for strengthening design.

Stability investigation of symmetrically porous advanced composites plates via a novel hyperbolic RPT

  • S.R. Mahmoud;E.I. Ghandourah;A.H. Algarni;M.A. Balubaid;Abdelouahed Tounsi;Abdeldjebbar Tounsi;Fouad Bourada
    • Steel and Composite Structures
    • /
    • v.46 no.4
    • /
    • pp.471-483
    • /
    • 2023
  • This paper presents an analytical hyperbolic theory based on the refined shear deformation theory for mechanical stability analysis of the simply supported advanced composites plates (exponentially, sigmoidal and power-law graded) under triangular, trapezoidal and uniform uniaxial and biaxial loading. The developed model ensures the boundary condition of the zero transverse stresses at the top and bottom surfaces without using the correction factor as first order shear deformation theory. The mathematical formulation of displacement contains only four unknowns in which the transverse deflection is divided to shear and bending components. The current study includes the effect of the geometric imperfection of the material. The modeling of the micro-void presence in the structure is based on the both true and apparent density formulas in which the porosity will be dense in the mid-plane and zero in the upper and lower surfaces (free surface) according to a logarithmic function. The analytical solutions of the uniaxial and biaxial critical buckling load are determined by solving the differential equilibrium equations of the system with the help of the Navier's method. The correctness and the effectiveness of the proposed HyRPT is confirmed by comparing the results with those found in the open literature which shows the high performance of this model to predict the stability characteristics of the FG structures employed in various fields. Several parametric analyses are performed to extract the most influenced parameters on the mechanical stability of this type of advanced composites plates.

Numerical investigation on the flow noise reduction due to curved pipe based on wavenumber-frequency analysis in pressure relief valve pipe system (감압 밸브 배관 시스템 내 파수-주파수 분석을 통한 곡관의 유동소음 저감에 대한 수치적 연구)

  • Garam, Ku;Cheolung, Cheong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.705-712
    • /
    • 2022
  • A sudden pressure drop caused by the pressure relief valve acts as a strong noise source and propagates the compressible pressure fluctuation along the pipe wall, which becomes a excitation source of Acoustic Induced Vibration (AIV). Therefore, in this study, the numerical methodology is developed to evaluate the reduction effect of compressible pressure fluctuation due to curved pipe in the pressure relief valve system. To describe the acoustic wave caused by density fluctuation, unsteady compressible Large Eddy Simulation (LES) technique, which is high accuracy numerical method, Smagorinsky-Lilly subgrid scale model is applied. Wavenumber-frequency analysis is performed to extract the compressible pressure fluctuation component, which is propagated along the pipe, from the flow field, and it is based on the wall pressure on the upstream and downstream pipe from the curved pipe. It is shown that the plane wave and the 1st mode component in radial direction are dominant along the downstream direction, and the overall acoustic power was reduced by 3 dB through the curved pipe. From these results, the noise reduction effect caused by curved pipe is confirmed.

Vibrational energy flow in steel box girders: Dominant modes and components, and effective vibration reduction measures

  • Derui Kong;Xun Zhang;Cong Li;Keer Cui
    • Steel and Composite Structures
    • /
    • v.50 no.3
    • /
    • pp.347-362
    • /
    • 2024
  • Controlling vibrations and noise in steel box girders is important for reducing noise pollution and avoiding discomfort to residents of dwellings along bridges. The fundamental approach to solving this problem involves first identifying the main path of transmission of the vibration energy and then cutting it off by using targeted measures. However, this requires an investigation of the characteristics of flow of vibration energy in the steel box girder, whereas most studies in the area have focused on analyzing its single-point frequency response and overall vibrations. To solve this problem, this study examines the transmission of vibrations through the segments of a steel box girder when it is subjected to harmonic loads through structural intensity analysis based on standard finite element software and a post-processing code created by the authors. We identified several frequencies that dominated the vibrations of the steel box girder as well as the factors that influenced their emergence. We also assessed the contributions of a variety of vibrational waves to power flow, and the results showed that bending waves were dominant in the top plate and in-plane waves in the vertical plate of the girder. Finally, we analyzed the effects of commonly used stiffened structures and steel-concrete composite structures on the flow of vibration energy in the girder, and verified their positive impacts on energy regionalization. In addition to providing an efficient tool for the relevant analyses, the work here informs research on optimizing steel box girders to reduce vibrations and noise in them.

Quantitative EC Signal Analysis on the Axial Notch Cracks of the SG Tubes (SG Tube 축방향 노치 균열의 정량적 EC 신호평가)

  • Min, Kyong-Mahn;Park, Jung-Am;Shin, Ki-Seok;Kim, In-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.374-382
    • /
    • 2009
  • Steam generator(SG) tube, as a barrier isolating primary to the secondary coolant system of nuclear power plants(NPP), must maintain the structural integrity far the public safety and its efficient power generation capacity. And SG tubes bearing defects must be timely detected and taken repair measures if needed. For the accomplishment of these objectives, SG tubes have been periodically examined by eddy current testing(ECT) on the basis of administrative notices and intensified SG management program(SGMP). Stress corrosion cracking(SCC) on the SG tubes is not easily detected and even missed since it has lower signal amplitude and other disturbing factors against its detection. However once SCC is developed, that can cause detrimental affects to the SG tubes due to its rapid propagation rate. Accordingly SCC is categorized as prime damage mechanism challenging the soundness of the SG tubes. In this study, reproduced EDM notch specimens are examined for the detectability and quantitative characterization of the axial ODSCC by +PT MRPC probe, containing pancake, +PT and shielded pancake coils apart in a single plane around the circumference. The results of this study are assumed to be applicable fur providing key information of engineering evaluation of SCC and improvement of confidence level of ECT on SG tubes.

Harmonic Suppression Compact Microstrip Patch Antenna for IoT Sensor (고조파 억제를 위한 IoT 센서용 소형 마이크로스트립 패치 안테나)

  • Lee, Hyun-Seung;Lim, Jeong-Taek;Jung, Bang-Chul;Kim, Choul-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.85-89
    • /
    • 2017
  • This paper proposes an antenna incorporating a bandstop filter to miniaturize the rectenna used for wireless power transmission with the emerging interest these days. To suppress the harmonics that can be re-radiated, this paper proposes a microstrip patch antenna that can suppress the harmonics while maintaining the size of the antenna by inserting a U-slot, which acts as a bandstop filter, on the ground plane of the antenna. As a result, S11 of the second harmonic(4.6GHz) was reduced from -5.61dB to -0.338dB and the efficiency was suppressed significantly from 29.76% to 1.5%. In addition, the maximum gain was reduced to -12dBi from 2.89dBi. On the other hand, at the fundamental frequency (2.45GHz), the S11 value was reduced from -18 dB to -15 dB, and the efficiency was reduced slightly from 68.2% to 60%. In the case of applying a microstrip antenna combined with the proposed bandstop filter to a rectenna, it is believed that the harmonics that degrade the performance of the rectenna can be removed effectively while reducing the large area occupied by harmonic suppression.

Design of Microstrip Patch Antenna using Inset-Fed Layered for Metallic Object in u-Port (U-항만 환경에서 금속부착을 위한 인셋 급전 마이크로패치 안테나 설계)

  • Choi, Yong-Seok;Seong, Hyeon-Kyeong
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.2
    • /
    • pp.80-85
    • /
    • 2015
  • In this paper, we present, an indstrial RFID layered microstrip patch antenna is designed using an inset feed method in order to improve recognition rates in a long distance as tags are attached to metal object by improving a problem of feeding power in fabricating metal tags and reducing effects of metallic object. The inset feed shows a distinctive characteristic that has no separation between emitters and feed lines differing from a structure with the conventional inductive coupling feed. This structure makes possible to produce a type that presents a low antenna height and enables impedance coupling for tag chips. Although it shows a difficulty in the impedance coupling due to increases in the parasite capacitance between a ground plane and an emitter in an antenna according to decreases in the height of a tag antenna, it may become a merit in designing the tag antenna because the antenna impedance can be determined as an inductive manner if a shorted structure is used for feeding power. Therefore, in this paper the microstrip patch antenna is designed as a modified type and applies the inset feed in order to reduce effects of metallic objects where the antenna is be attached. Also, the antenna uses a multi-layer structure that includes a metal plate between radiator and ground instead of using a single layer.