• 제목/요약/키워드: Power line modem

검색결과 127건 처리시간 0.026초

PLM을 이용한 선박 비상조명시스템의 모니터링 (Monitoring of Ship's Emergency Lighting System using PLM(SELP))

  • 임현정;양현숙;김건우;백영진;이성근;김윤식
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.105-106
    • /
    • 2006
  • In this paper we describe a driving, control and monitor of ship's emergency lighting system using power line modem.(PLM). Through this paper, experiment confirms that ON-OFF control of multiple SELP, real time transmission and monitor of parameters as to voltage, current, and power values are performed appropriately by PLM communication.

  • PDF

전력선 통신을 이용한 난방용 솔레노이드밸브 제어에 관한 연구 (A Study on the Control of Solenoid Valve for Heating by using Power Line Communication (PLC))

  • 신관우;김용태;이윤섭
    • 제어로봇시스템학회논문지
    • /
    • 제9권8호
    • /
    • pp.647-650
    • /
    • 2003
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance, and selective possibility of frequency property. We designed the boiler temperature control system unit by using the PLC modem. We can avoid unnecessary heating of separate temperature control unit, and save the cost accordingly control stability of the proposed system is proven through the experiment.

Broadband Impedance Matching Circuit Design for PLC Coupler Using Tchebycheff Equalizer

  • Kim, Gi-Rae;Tangyao, Xie
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.113-118
    • /
    • 2009
  • This paper is about design broadband impedance matching circuit for Coupler to improve power transfer efficiency in the power line communication (PLC) system. The Tchebycheff gain function algorithm is represented to design broadband matching circuit. A practical PLC Coupler impedance matching circuit is designed, and the characteristics for S11 and S21 of PLC coupler are enhanced comparing with unmatched one. This is done by maximizing the power transfer gain from modem to the load.

Design of Broadband Impedance Matching Circuit for PLC Coupler using Butterworth Equalizer

  • Xie, Tangyao;Kim, Gi-Rae
    • Journal of information and communication convergence engineering
    • /
    • 제8권3호
    • /
    • pp.258-262
    • /
    • 2010
  • This paper represents design broadband impedance matching circuit for Coupler to improve power transfer efficiency in the broadband power line communication(BPLC) systems. The Butterworth gain function equalizer is used to design broadband matching circuit. A practical PLC Coupler impedance matching circuit is designed, and the characteristics for S11 and S21 of PLC Coupler are enhanced comparing with unmatched one. This is done by maximizing the power transfer gain from modem to the load.

전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발 (Development of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power)

  • 윤재식;위정철;박중하;송용재;김재헌
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2281-2285
    • /
    • 2009
  • Powerline communication is the data signal which is modulated by carrier frequency through the installed powerline at in-home or office is transmitted and received signals are separated into data signal with using band-pass filter which cent-frequency is carrier frequency. The home gateway, an equipment which works as an gateway for ubiquitous home network, relays all functions of a home network. The home gateway must always be connected in order to provide seamless services. However it gives unfavorable power consumption. Therefore the needs for working in maximum power saving mode while there is no data traffic and for invoking to the normal function when it is necessary. So, in this paper we survey the development of low power PLC modem monitoring of power consumption and breaking abnormal power in the home Network.

옥내 전력선 통신 채널 임피던스 측정 장치 설계 (Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications)

  • 허윤석
    • 정보학연구
    • /
    • 제8권3호
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

Solar Power System의 인버터 토폴로지 및 제어 모드에 따른 안정도 연구 (Stability of Solar Power System on the Control Modes of a Forced-Commutated Inverter and a Line-Commutated Inverter)

  • 이승현;정교범;조보형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.534-537
    • /
    • 1997
  • Solar power systems have become popular in the modem electric energy system. In order to supply the DC power, generated by solar cells, to the electric power system, the solar power system requires DC-to-AC power conversion. A line-commutated inverter or a forced-commutated inverter can be used in the DC-to-AC power conversion. Because of the nonlinear V-I characteristics of the solar cells, multiple operating points determined by the control mode of the inverter exist in the DC V-I state plane of the solar power system. In this paper, the stability of utility-interactive solar power system with a line-commutated inverter is analyzed at various operating points, using the eigenvalue method and the state-plane analysis technique. The stability of a forced-commutated inverter case is also anaiyzed and compared to that of the line-commutated inverter case.

  • PDF

ADSL 모뎀 및 전력선통신용 전송장치에 관한 기술기준의 제정 연구 (Study on the Technical Specifications of ADSL Modem and Power-Line Communication Equipment)

  • 김용환;조평동;박기식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 추계종합학술대회
    • /
    • pp.415-418
    • /
    • 2001
  • 우리 나라에서는 공중통신망에 접속되는 단말장치에 대하여 통신망 안전을 위한 기술기준을 정하여, 유통되는 장치들은 이 기술기준을 만족하게 하는 형식승인제도를 운용하고 있다. 최근의 초고속 정보통신망의 활발한 이용과 더불어 기존의 기술기준을 보완하는 작업이 이루어지고 있으며, 이 논문에서는 대표적인 안건으로써 ADSL 모뎀과 전력선통신용 전송장치에 관한 기술기준의 제정 방안에 관하여 논의하였다.

  • PDF

전력선 통신을 이용한 인터넷 맵 연동 전자계량기 모니터링 시스템 구현 (Implement of Watt-Hour Meter Monitoring System by Internet Map Based GUI using Power Line Communication)

  • 박근수;이영호
    • 한국전자통신학회논문지
    • /
    • 제8권10호
    • /
    • pp.1435-1441
    • /
    • 2013
  • 본 논문에서는 가정용 계량기의 데이터를 PC로 모니터링할 수 있도록, 전력선 통신(PLC : Power Line Communication) 모뎀과 인터넷맵 기반의 데이터 수집장치를 GUI모니터링 시스템으로 구현하였다. 전력선 통신 모뎀은 기존의 전력선에 데이터를 실어 보내는 기술로 별도의 신호선 설치에 대한 부담을 줄인다. 본 논문에서 제안하는 GUI모니터링 시스템은 인터넷맵 정보를 활용하여 가정용 개량기의 전, 현 월 사용 전력량을 인터넷 맵에서 시각적으로 편리하게 모니터링 할 수 있다. 이 구현은 일반인(비전문가)도 PC상에서 쉽게 전기사용정보를 확인하도록 하여 요금 관리 및 고장 관리에 편의를 제공하도록 한다.

전력선 통신을 이용한 원격 전력분석 및 제어시스템에 관한 연구 (The study of the remort power analysis and control system using power line communication)

  • 최원호;이후찬;박종연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.211-213
    • /
    • 2005
  • RPA(Remelt Power Analysis)and RC(Remote Control) System have been researched from former several decade for a various power rate system a efficent power service and rising of personal expenses, etc. But the existing RPA and RC System have disadventage which are complex and high cost to install an individual communication network of electricity company This paper proposed a new type of RPA and RC System using PLC with Internet. and made components for proposal system so we made the PLC modem, the digital watt-hour meter with a build in PLC modem and the softwere on server computer for establishing the proposal system. The bit rate of the proposed system is about 4800bps.

  • PDF