• 제목/요약/키워드: Power line communication:PLC

검색결과 278건 처리시간 0.026초

전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발 (Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication)

  • 김상동;박지호;김동완
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

PLC에서의 구동회로설계에 관한 연구 (A study on the Drive Circuit Design in the Power Line Communication)

  • 최태섭;임승하
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.1301-1304
    • /
    • 2005
  • 본 논문에서는 전력선 통신 시스템에서 급격하게 변화는 임피던스 때문에 발생하는 에러율을 개선하기 위하여 제안한 D급 증폭 구동 회로를 적용하였다. 전력선 모뎀에, 일반적인 구동회로인 전압 구동 회로와 전류 구동 회로를 제작하여 실험을 하였다. 그리고 같은 전력선 모뎀에 본 논문에서 제안한 D급 증폭 회로를 이용한 구동 회로를 사용하여 실험을 하였다. 실험 결과 본 논문에서 설계한 구동 회로가 전력선 통신에서 임피던스 변화에 대하여 다른 구동 회로보다 성능이 우수함을 보였다.

  • PDF

옥내 전력선 통신 채널 특성 측정 (Measurement of the indoor power line channel characteristic)

  • 허윤석
    • 정보학연구
    • /
    • 제7권3호
    • /
    • pp.1-10
    • /
    • 2004
  • 옥내${\cdot}$외의 전력선 환경에 대한 정확한 채널 모델링에 관한 노력이 최근에 이루어지고 있다. 알려진 일반표준, 제한과 발표된 모델들은 특별한 형태의 접근들이였다. 본 논문에서는 더 신속하고 효율적인 전력선 통신 실험을 위한 전력선 채널 모델링에 관한 연구이다. 용량성 부하 시뮬레이터는 전력선 옥내 망 모뎀 개발에 필수적인 장비이다. 총 244 경우의 용량성 부하 변화에 대한 주파수 응답 특성 측정으로 채널 모델링을 수행하였다. 본 측정 실험에서 PLC는 일반적으로 알고 있었던 특성 보다 더 확정적인 매체라는 것을 확인하였다.

  • PDF

전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발 (Development of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power)

  • 윤재식;위정철;박중하;송용재;김재헌
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2281-2285
    • /
    • 2009
  • Powerline communication is the data signal which is modulated by carrier frequency through the installed powerline at in-home or office is transmitted and received signals are separated into data signal with using band-pass filter which cent-frequency is carrier frequency. The home gateway, an equipment which works as an gateway for ubiquitous home network, relays all functions of a home network. The home gateway must always be connected in order to provide seamless services. However it gives unfavorable power consumption. Therefore the needs for working in maximum power saving mode while there is no data traffic and for invoking to the normal function when it is necessary. So, in this paper we survey the development of low power PLC modem monitoring of power consumption and breaking abnormal power in the home Network.

PLC를 이용한 개선된 자동 조명제어시스템 구현 (Implementation of Improved Automatic Lighting System using PLC)

  • 강신욱;주진환;권학철;이석규;박주현
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.99-106
    • /
    • 2010
  • 본 논문에서는 조명에너지 사용을 절감하기 위하여 설계된 자동 조명제어시스템에 전력선 통신(PLC : Power Line Communication)과 단문문자서비스(SMS : Short Message Service)를 적용한 개선된 자동 조명제어시스템을 구현하였다. 본 시스템은 자동 조명제어장치와 함께 재실감지센서에 의하여 화재나 침입자 발생 시 경고음 뿐만 아니라 관리자나 사용자에게 경고 메세지를 전송하여 2차 사고를 예방할 수 있도록 설계되어 있다. 또한 본 논문에서는 전력전송을 위하여 설치된 기존의 전력선에 데이터를 실어 보냄으로써 신호선과 전원선의 통합하여 조명 제어를 위하여 사용되는 라인의 수를 획기적으로 줄이는 개선된 자동 조명제어시스템을 제안하였다.

전력선 통신 응용을 위한 저압 댁내망의 채널 특성 분석 기법에 관한 연구 (A Study on the channel characteristics of the household AC power line used for the low bit rate communication home network)

  • 안남호;장태규;황경태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.305-307
    • /
    • 2001
  • In this paper, the household AC power line network is characterized for the low bit rate power line communication (PLC) in the frequency range from 10kHz to 450kHz. Various types of electric apparatus and the power lines constitute the network topology, and the PLC channel transfer function and the channel impedance are derived based on the constructed network topology. The channel characteristics derived with the lumped circuit model and the distributed circuit model are compared using the computer simulations. The effect of the wave reflection and signal distortions are also investigated.

  • PDF

저속 PLC 모뎀을 위한 대기전력 절감 모듈 개발 (A Development of Module Operating on Standby-power Reduction for Low-speedy PLC Modem)

  • 김기현;김지홍;김남균;김상철;서길수;김은동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1537-1539
    • /
    • 2004
  • This paper introduces a supplementary module reducing the standby-power of Power Line Communication(PLC) modem, one of the network equipments that take up much of the stand-by power. This supplementary module consists of three parts, such as a compare part, a control part, and a switch part. This supplementary module controls the power going from the power supply element into PLC modem, which brings about the effect of standby-power reduction. It is assured that over $30\%$ standby-power reduction is estimated when we applied this module to a low-speedy PLC control modem.

  • PDF

Jini Surrogate에 기반한 광대역 PLC 홈 제어기 개발 (Development of the Jini Surrogate-based Broadband PLC Home Controller)

  • 김희선;이창구
    • 제어로봇시스템학회논문지
    • /
    • 제12궈1호
    • /
    • pp.1-8
    • /
    • 2006
  • The home network system guarantees families a safe, economical, socially integrated and healthy life by using information appliances. And it provides a family with domestic safety, control of instruments, controllable energy and health monitoring by connecting to home appliances. This study designs the broadband PLC home controller using broadband PLC(Power Line Communication) technology which can save much cost at a network infrastructure by using the existing power line at home. The broadband PLC home controller consists of the broadband PLC module, the embedded main controller module and I/O module. The broadband PLC home controller can control various domestic appliances such as an auto door-lock, a boiler, an oven, etc., because it has various I/O specifications. In this study, selected home network middleware for the broadband PLC home controller is Jini surrogate using Jini technology designed by means of access to easily a home network system without a limitation of the devices. And a client application program is supported java servlet program to manage and monitor the broadband PLC home controller via web browser of a PC or a PDA, etc. Finally, for an application, we implemented and tested a home security system using one broadband PLC home controller.

전력선통신을 이용한 전력품질 측정시스템 (Power Quality Measurement System of using PLC)

  • 홍덕표;이진목;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.90-92
    • /
    • 2005
  • As the developing of industry, the nonlinear equipments as inverter, converter, SMPS(Switching Mode Power Supply) and motor have been increased. But the sensitive electronic loads to the power quality, such as computer's and other electronic equipments, have been spreaded out very fast. Thus, the power quality (PQ) problems and the real time power quality monitoring (PQM) are one of the important issues industry and building area for the intelligent control of the systems. One of them, PQM using PLC(Power Line Communication) have good merits that can send and receive the PQ information without any new network line. This paper presents the PQM hardware and software to monitor the PQ information by using PLC that meets the categories of IEEE Std. 1159.

  • PDF

중형급 풍력 발전기내 전력선을 이용한 무배선 통신 성능분석 (Performance analysis of legacy line communication using high current powerlines in midrange wind turbines)

  • 김경화;정성욱;남승윤;김현식;손경락
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.336-341
    • /
    • 2016
  • 본 논문에서는 풍력 발전기 내 기 설치된 전력선을 통신 선로로 사용하여 통신 네트워크를 구축하는 기술인 무배선 감시 시스템을 제안한다. 전력선과 데이터통신 기기의 연결을 위하여 발전기의 다양한 전류 및 전압 변화에서도 안정적인 통신이 가능한 유도성 결합장치와 복합통신장치를 사용하였다. 실제 운영되고 있는 풍력 발전기를 대상으로 선로 특성분석을 통해 전력선 통신의 구축 가능성을 확인 후 영상 전송 시스템을 구현하였다. 구현된 전력선 통신 시스템은 43Mbps 이상의 전송속도를 제공하고, 통신 성공률은 100%로 실시간 비디오 영상 전송이 가능함을 확인했다. 따라서 제시된 시스템은 통신 선로의 추가 설치 없이도 풍력 발전기에 통신 네트워크 구축이 가능하며, 전력선 통신 네트워크 기반의 실시간 감시 시스템을 도입하는 경우 매우 효과적일 것으로 기대된다.