• Title/Summary/Keyword: Power factor improvement

Search Result 383, Processing Time 0.028 seconds

Effect of CrossFit Power Training on TPI OnBaseU Power Test and Golf Performance (크로스핏 파워 트레이닝이 TPI OnBaseU Power Test와 골프 수행력에 미치는 영향)

  • Chang Wook Kim
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.4
    • /
    • pp.185-195
    • /
    • 2023
  • Objective: The purpose of this study is to improve TPI OnBaseU Power Test and golf performance by conducting CrossFit power training. Method: Three male golf players from University B participated in this study. They had 3 to 4 years of golf experience and participated in 8 weeks of CrossFit power training. Results: OnBaseU Power Test: There was a lot of improvement in Sit up throw (27.9%) and Chest pass (10.58%), but there was not much improvement in Baseline Toss (R5.9, L9.8%) and Vertical Jump (4.1%). Golf shot data: There was a very statistically significant difference in Club speed, Ball speed, and Total Length, which are related to speed, and there was no difference in Club path and Smash factor, which are related to accuracy and posture. Conclusion: CrossFit power training was effective in improving TPI OnBaseU Power Test and golf performance (Club speed, Ball speed, Total Length).

Improvement of Grounding for the Armoured Communication Cables (통신용 차폐케이블의 접지방안 개선)

  • Oh, H.S.;Lee, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.64-68
    • /
    • 1994
  • This paper presents the structures, characteristics and shield factor of armoured communication cables used against power induction problems. The decision methods of grounding resistance and calculation formulas of shield factor are considered and improvement methods of domestic installation practice are presented.

  • PDF

Optimal Control Scheme for Matrix Converter (매트릭스컨버터의 최적제어기법 고찰)

  • Cho, Choon-Ho;Mo, Dong-Yeong;Lee, Sang-Chul;Choi, Chang-Young;Lee, Gun-Sik;Kim, Tae-Woong;Park, Gwi-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.21-22
    • /
    • 2010
  • Matrix converter is direct power conversion system. Matrix converter has many merits that possible bidirectional power flow, input power factor own control and system without DC-link. But matrix converter has some demerits that need many switching devices and switching loss. This paper suggest optimal matrix converter control scheme for improvement for switching loss part. Proposed control scheme verified that 10% improvement in efficiency, input current's harmonic loss and output voltage's EMI improvement.

  • PDF

Using Voltage Control Active Power Filter, Power Factor Improvement and Harmonics Reduction for Nonlinear Load (전압제어형 능동전력필터를 이용한 비선형부하의 고조파저감 및 역류개선)

  • 김병진;문학룡;송양희;임병국;전희종
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.403-408
    • /
    • 2000
  • In this paper, voltage control APF(Active Power Filter) is introduced to improve power factor and reduce harmonics generated from nonlinear load. The voltage controlled APF which is consisted of inverter and passive filter operates with nonlinear load simultaneously. Real power supplies from main power to load and reactive power provides from APF to load. According to the results o experiment and simulation, it is proved that the proposed system has the performance of improving power factor and reducing harmonics.

  • PDF

Reliability Cost Evaluation of Power Distribution System with Superconducting Fault Current Limiter (초전도 한류기 적용시 배전계통의 신뢰도 비용 평가)

  • Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.266-270
    • /
    • 2014
  • In this paper, the effects of superconducting fault current limiter (SFCL) installed in power distribution system on reliability are evaluated and analyzed. The fault current will be decreased in power distribution system with SFCL because of the increased impedance of SFCL. The decreased fault current will improve the voltage drop of the bus of substation. The voltage drop is an important factor of power distribution system reliability. In this paper, improvement of reliability worth is analyzed when SFCLs are installed at the starting point in power distribution system. First, resistor-type SFCL model is used in PSCAD/EMTDC. Next, typical power distribution system is modeled. Finally, when the SFCLs with impedance 0.5 [${\Omega}$] are installed in feeder, power distribution system reliability is evaluated. Also, the improvement effect of reliability worth including the effect of voltage sag is analyzed using customer interruption cost according to whether or not SFCL is installed.

Static Characteristics Analysis of PWM Cuk AC-AC Converter for Power Quality Improvement of Custom Power (Custom Power의 전력품질 향상을 위한 PWM Cuk AC-AC 컨버터의 정적 특성 해석)

  • 최남섭
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.513-516
    • /
    • 2004
  • In this paper, a PWM Cuk AC-AC converter for power quality improvement of custom power is presented. The PWM Cuk AC-AC converter that is used in VVCF applications such as AC line conditioner, phase shifter is modelled by using complex circuit DQ transformation whereby the static characteristics equations such as voltage gain and power factor is analytically obtained. Finally, the PSIM simulation show the validity of the modelling and analysis.

  • PDF

A Study on Improving Power Quality by Real-time Reactive Power/Power Factor Compensating Equipment at Substation in Marshalling Yard (전기철도 차량기지 변전소의 실시간 무효전력/역률 보상설비 적용에 따른 전력품질 개선에 관한 연구)

  • Park, Soo-Cheol;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.58-67
    • /
    • 2006
  • In this paper, real-time reactive power/power factor compensating equipment is suggested for improving power quality at electrical railway's substation in marshalling yard and designing optimal capacity of compensating equipment for actual apply at current marshalling yard. For this purpose, several kind of real-time reactive power/power factor compensating equipments are introduced and SVG(Static Var Generator) as optimal compensating equipment that is suitable for load characteristics of substation in marshalling yard is suggested. This paper shows proper simulations by suggested equipment using PSIM software and describe basic compensating principle and simulation results. Optimal capacity design for applying current marshalling yard is based on real measured power quality data. Power quality improvement that is performed by SVG as real-time reactive power/power factor compensating equipment is estimated at electrical railway's substation in marshalling yard. As reference, real-time reactive power/power factor compensating equipment is composed by voltage source inverter and DC capacitors.

A Study on the Design Standard of Demand Factor and Diversity Factor (건물의 수요율 및 부등율 기준설정에 관한 연구)

  • 지철근;곽희로;강원구
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.4 no.1
    • /
    • pp.54-62
    • /
    • 1990
  • This paper shows a reasonable design standard of Demand Factor and Diversity Factor for buildings, that was made by the systematic and statistical way considering actual conditions, such as investicated electric equipment capacity, electric power consumption, etc. The saving of electric equipment investment, the decrease of power loss, the improvement of facilities utilization and the decrease of electric power rates, can be contributed by the application of the design standard. The recommended design standard must be applied by the revision of current regulations and laws.

  • PDF

Power Factor Correction Improvement and Total Harmonic Distortion Reducing for Panel's Air-conditioner (패널용 에어컨의 역률 개선 및 고조파 저감)

  • Park, S.W.;Park, J.W.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.258-261
    • /
    • 2001
  • High Power factor Active Filter converter is used for Inverter Air conditioner power supply to meet IEC standard. In the active filter topology for power factor, extra switch just control the input current indirectly to meet the IEC standard for reducing the cost and size. In this paper, low cost converter was suggested by simulation using extra switch which auxiliary pulse is inserted and quasi resonant soft switching topology control is adapted for panel's inverter air conditioner converter Inserting auxiliary Pulse method to the extra switch has the benefit of reducing THD by low cost input control circuit. And also quasi resonant soft switching topology can reduce switching loss. So both technical is suitable for Panel's Air conditioner.

  • PDF

Characteristic improvement of the forward type high voltage pulse power supply for Lamp Type Ozonizer (램프형 오존발생기용 Foward형 고압 펄스전원장치의 특성개선)

  • Kim, Kyung-Sik;Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Gyun;Nam, Seung-Sik;Sim, Kwang-Yeal
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1117-1119
    • /
    • 2001
  • This paper describes the forward type pulse power supply using a Power-MOSFET in the view of commercialization. The principle of basic operating and the operating characteristics of the forward type pulse power supply are estimated by the switching frequency, coupling factor and duty ratio. It is shown that theoretical and experimental results are in good agreement by comparing simulation and experimental results when a lamp type ozonizer can be used as a load. Also, experimental results indicate that the discharge and ozone concentration characteristics of the manufactured pulse power supply is more improved compare to the conventional pulse power supply[5]. This proposed supply show that it can be practically used as a pulse power supply in various environment improvement facilities.

  • PDF