• Title/Summary/Keyword: Power factor improvement

Search Result 383, Processing Time 0.028 seconds

Power Transformer Diagnosis Using a Modified Self Organizing Map

  • Lee J. P.;Ji P. S.;Lim J. Y.;Kim S. S.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Substation facilities have become extremely large and complex parts of electric power systems. The development of condition monitoring and diagnosis techniques has been a very significant factor in the improvement of substation transformer security. This paper presents a method to analyze the cause, the degree, and the aging process power transformers by the Self Organizing Map (SOM) method. Dissolved gas data were non-linearly transformed by the sigmoid function in SOM that works much the same way as the human decision making process. The potential for failure and the degree of aging of normal transformers are identified by using the proposed quantitative criterion. Furthermore, transformer aging is monitored by the proposed criterion for a set of transformers. To demonstrate the validity of the proposed method, a case study is performed and its results are presented.

Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load (불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법)

  • Lee, Wujong;Jo, Jongmin;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

Orthogonal variable spreading factor encoded unmanned aerial vehicle-assisted nonorthogonal multiple access system with hybrid physical layer security

  • Omor Faruk;Joarder Jafor Sadiqu;Kanapathippillai Cumanan;Shaikh Enayet Ullah
    • ETRI Journal
    • /
    • v.45 no.2
    • /
    • pp.213-225
    • /
    • 2023
  • Physical layer security (PLS) can improve the security of both terrestrial and nonterrestrial wireless communication networks. This study proposes a simplified framework for nonterrestrial cyclic prefixed orthogonal variable spreading factor (OVSF)-encoded multiple-input and multiple-output nonorthogonal multiple access (NOMA) systems to ensure complete network security. Various useful methods are implemented, where both improved sine map and multiple parameter-weighted-type fractional Fourier transform encryption schemes are combined to investigate the effects of hybrid PLS. In addition, OVSF coding with power domain NOMA for multi-user interference reduction and peak-toaverage power ratio (PAPR) reduction is introduced. The performance of $\frac{1}{2}$-rated convolutional, turbo, and repeat and accumulate channel coding with regularized zero-forcing signal detection for forward error correction and improved bit error rate (BER) are also investigated. Simulation results ratify the pertinence of the proposed system in terms of PLS and BER performance improvement with reasonable PAPR.

Thermal Treatment Effect on Thermoelectric Characteristics of Perovskite La0.5Ca0.5MnO3 (페로브스카이트 La0.5Ca0.5MnO3 재료의 열전 특성에 미치는 열처리 효과)

  • Yang, Su-Chul
    • Journal of the Korean Electrochemical Society
    • /
    • v.20 no.3
    • /
    • pp.55-59
    • /
    • 2017
  • In this study, thermoelectric characteristics of perovskite $La_{0.5}Ca_{0.5}MnO_3$ (LCMO) nanomaterials were investigated by theoretical simulation and experimental analysis. Thermoelectric power factors calculated by DFT simulation were gradually enhanced as increase in annealing temperature. Maximum power factor was obtained with high magnitude of $S^2{\sigma}=566{\mu}W/m{\cdot}K^2$ at 1100 K through a dominant improvement of Seebeck coefficient compared with electrical conductivity. Experimentally, the LCMO nanomaterials were hydrothermally synthesized and then treated by post thermal annealing with temperature variation. X-ray diffraction and SEM analysis illustrated that LCMO exhibited orthorhombic perovskite structures with small grain size of 16~19 nm over 873 K. The results directly confirmed that improvement of crystallinity and decrease of mean grain size given by post thermal annealing lead to enhancements of electrical conductivity and Seebeck coefficient, respectively.

A study on the power factor improvement of the Boost Forward Converter (BF 컨버터의 역률 개선에 관한 연구)

  • 임승하
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.3
    • /
    • pp.56-63
    • /
    • 1999
  • In this paper, we realize the active PFC(Power Factor Correction) system of BF (Boost Forward) converter with PWM-PFM control technique to control DC output voltage, and to control the input current with sinusoidal wave synchronized by the converter and inverter using power switching element, FET and IGBT. The control circuit of the suggested Boost converter is implemented with a microprocessor 80C196. After making the ratio of output voltage to current as 50V/1A and the duty ratio greater than 0.5. When input voltage is 30V and boost inductance is 1.1mH. We control the voltage changing rate according to the variation of load resistance using a PWM-PFM control technique. And finally we prove experimentally. PF can be improved up to 0.96 using the current shaping technique.

  • PDF

Eco-Efficiency Assessment of the Recycling Process in Resources Recycling Center (자원재활용센터의 재활용 공정에 대한 생태효율성 평가)

  • KIM, Tae-Seok;KIM, Dong-Gyue;CHUNG, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1812-1821
    • /
    • 2015
  • In this study, we evaluate the eco-efficiency for recycling processes of Busan Resources Recycling Center for each year from 2010-2012. It analyze the impact of global warming on the power consumption by Life Cycle Assessment. Also calculate the economic value by net profit components those are sales amount and electric charge in accordance with the process operation. On the basis of these results, each of the eco-efficiency Factor analysis and dynamics analysis of 2011 and 2012 as the base year to 2010 are performed. As a result, the impact of global warming in all the recycling processes is increased by increasing power consumption 2010-2012. But net profit is decreased. In addition, the eco-efficiency of all the recycling processes is decreased and analysis result of the eco-efficiency trends is located on the Fully non Eco-efficiency (--) level. Therefore, all the recycling processes are necessary improvement for power consumption reducing and net profit increasing to further the environmental and economically sustainable direction.

Improving the Dynamic Performance of Distribution Electronic Power Transformers Using Sliding Mode Control

  • Hooshmand, Rahmat-Allah;Ataei, Mohammad;Rezaei, Mohammad Hosein
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.145-156
    • /
    • 2012
  • These days, the application of electronic power transformers (EPTs) is expanding in place of ordinary power transformers. These transformers can transmit power via three or four wire converters. Their dynamic performance is extremely important, due to their complex structure. In this paper, a new method is proposed for improving the dynamic performance of distribution electronic power transformers (DEPT) by using sliding mode control (SMC). Hence, to express the dynamic characteristics of a system, different factors such as the voltage unbalance, voltage sag, voltage harmonics and voltage flicker in the system primary side are considered. The four controlling aims of the improvement in dynamic performance include: 1) maintaining the input currents so that they are in sinusoidal form and in phase with the input voltages so they have a unity power factor, 2) keeping the dc-link voltage within the reference amount, 3) keeping the output voltages at a fixed amount and 4) keeping the output voltages in sinusoidal and symmetrical forms. Simulation results indicate the potential and capability of the proposed method in improving DEPT behavior.

Design of Drive Line Shape for Reflective Magneto-Optic Spatial Light Modulator with High Switching Sensitivity by Computer Simulation (컴퓨터 시뮬레이션을 통한 고 스위칭 감도를 갖는 반사형 자기 광학 공간 광 변조기의 드라이브 라인 형상 설계)

  • 박재혁;조재경
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.2
    • /
    • pp.93-98
    • /
    • 2000
  • Drive line shape for reflective magneto-optic spatial light modulator has been designed by computer simulation. A factor of 3 improvement in pixel switching sensitivity and power consumption, compared to the conventional reflective magneto-optic spatial light modulator, has been achieved by the use of wedge-shape drive line and a soft magnetic layer. A factor of 2 higher optical efficiency and a factor of 2 simpler fabrication process have been achieved by the use of drive lines that covers most of the surface of pixel and unpatterned insulator.

  • PDF

Prediction of Vehicle Fuel Consumption on a Component Basis (가솔린 차량의 각 요소별 연료소모량 예측)

  • 송해박;유정철;이종화;박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.203-210
    • /
    • 2003
  • A simulation study was carried to analyze the vehicle fuel consumption on component basis. Experiments was also carried out to identify the simulation results, under FTP-75 Hot Phase driving conditions. and arbitrary driving conditions. A good quantitative agreement was obtained. Based on the simulation, fuel energy was used in pumping loss(3.7%), electric power generation(0.7%), engine friction(12.7%), engine inertia(0.7%), torque converter loss(4.6%), drivetrain friction(0.6%), road-load(9.2%), and vehicle inertia(13.4%) under FTP-75 Hot Phase driving conditions. Using simulation program, the effects of capacity factor and idle speed on fuel consumption were estimated. A increment of capacity factor of torque converter resulted in fuel consumption improvement under FTP-75 Hot Phase driving conditions. Effect of a decrement of idle speed on fuel consumption was negligible under the identical driving conditions.

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.