• 제목/요약/키워드: Power facilities

검색결과 2,003건 처리시간 0.027초

농촌 공간 환경영향요인 분석을 위한 무인항공기 적용 가능성에 관한 실험적 연구 - 홍성군 갈산면의 태양광 발전시설과 빈집을 중심으로 - (An Experimental Study on the Applicability of UAV for the Analysis of Factors Influencing Rural Environment - Focusing on Photovoltaic Facilities and Vacant House in Galsan-Myeon, Hongseong-gun -)

  • 안필균;엄성준;김수연;김용균
    • 한국농촌건축학회논문집
    • /
    • 제24권1호
    • /
    • pp.9-17
    • /
    • 2022
  • Rural spaces are increasingly valuable as areas for introducing renewable energy infrastructure to achieve carbon neutrality. Rural areas are the living grounds of rural residents, and the balance of conservation and development for rural areas is important for the introduction of reasonable facilities. In order to maintain a balance between development and preservation and to introduce reasonable renewable energy facilities, it is necessary to develop a current status survey and an effective survey method to utilize a space capable of introducing renewable energy facilities such as idle land and vacant houses. Therefore, this study was conducted to verify the readability using an unmanned aerial vehicle, and the main results are as follows. The detection of photovoltaic power generation facilities using unmanned aerial vehicles was effective in analyzing the location and area of photovoltaic panels located on the roofs of buildings, and it was possible to calculate the expected power generation by region through the area calculation of photovoltaic panels. The vacant house detection can be used to select an investigation target for an vacant house condition survey as it can identify damage to buildings that are expected to be empty houses, management status, and electricity supply facilities through aerial photos. It is judged that the unmanned aerial vehicle detection capability can be utilized as a method to improve the efficiency of investigation and supplement the data related to solar power generation facilities and vacant houses provided by public institutions. Although this study detected the status of solar power generation facilities and vacant houses through high-resolution aerial image analysis, as a follow-up study, automatic measurement methods using the temperature difference of solar power generation facilities and general characteristics of vacant houses that can be read from the air were investigated. If the deriving research is carried out, it is judged that it will be possible to contribute to the improvement of the accuracy of the detection result using the unmanned aerial vehicle and the expansion of the application range.

물류 시스템 적용 유도전동기의 전압강하와 역률 보상 관계 (Voltage Drop and Power Factor Compensation Relation of Induction Motor applied to Logistics System)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제67권3호
    • /
    • pp.155-159
    • /
    • 2018
  • Recently, the expansion or establishment of facilities for the logistics system is increasing. Conveyor facilities play a major role in sorting and transporting logistics. Induction motors are widely used for the operation of these conveyor systems. In the logistics system, a large number of induction motors are used. These motors have a considerable distance from the power source side and have a low power factor. The installation position for the power factor compensation of the induction motor is very important. Since the voltage drop depends on the length of the line, it is an important parameter in capacitor capacity determination for power factor compensation. The capacity of the capacitors installed to compensate the power factor of the inductive load should be designed to the extent that self-excitation does not occur. In this study, we analyze the method of compensating the proper power factor considering the voltage drop and the installation position of the induction motor in the logistics system.

군부대 유휴부지를 활용한 탄소 순 배출량 제로 달성을 위한 태양광 패널 및 수소 연료 저장시설의 설치 규모 예측 (A Study on Predicting Installation Scale of Photovoltaic Panels and Hydrogen Fuel Storage Facilities to Achieve Net Zero Carbon Emissions Exploiting Idle Sites of Military Bases)

  • 문동학;허지용
    • 한국군사과학기술학회지
    • /
    • 제27권1호
    • /
    • pp.8-14
    • /
    • 2024
  • In this study, the scale of renewable photovoltaic(PV) panels and hydrogen fuel storage facilities required to achieve "net zero carbon emissions" in military facilities were predicted based on actual electricity consumption. It was set up to expect the appropriate installation size of PV panel and hydrogen fuel storage facility for achieving carbon neutrality, limited to the electricity consumption in the public sector, including national defense and social security administration in Yeongcheon. The experimental results of this paper are largely composed of two parts. First, representative meteorological factors were considered to predict solar power generation in the Yeongcheon area, and solar power generation was estimated through a multiple regression model using deep learning techniques. Second, the size of solar power generation facilities and hydrogen storage facilities in military bases was estimated with the amount of solar power generation and electricity consumption. As a result of this analysis, it was calculated that a site of 155.76×104 m2 for PV panels was needed and a facility capable of storing 27,657 kg of hydrogen gas was required. Through these results, it is meaningful to demonstrated the prospect that military units can lead the achievement of "carbon net zero 2050" by using PV panels and hydrogen fuel storage facilities on idle sites of military bases.

기후변화 영향을 고려한 유출변화에 따른 북한 수자원시설 발전량 평가 (An evaluation on power generation of water resources facilities in North Korea considering climate change)

  • 어규;이찬희;심우배;안재현
    • 한국수자원학회논문집
    • /
    • 제51권4호
    • /
    • pp.355-369
    • /
    • 2018
  • 기후변화 영향으로 미래의 유출량은 변화할 것이다. 미래 유출량의 변화는 수자원시설에 유입량을 변화시켜 발전량에 영향을 미친다. 본 연구는 기후변화로 인한 유출변화에 따른 북한 수자원시설 발전량을 평가하였다. 수자원시설에 대한 발전량은 물의 에너지에 의해 수차 발전기를 회전시켜 전력을 발생시킨다. 즉, 물의 위치에너지를 운동에너지로 바꾸고 운동에너지를 다시 전기에너지로 변화시키는 것이다. 본 연구의 평가 결과, 북한 수자원시설 발전량은 현재보다 2011년부터 2040년까지 감소하였고, 2041년부터 2100년까지는 증가하였다. 또한, 기존 북한 수자원시설의 발전량은 미래에 감소하거나 현재와 비슷하게 나타났다. 신규 북한 수자원시설의 발전량은 단기적으로는 감소하지만, 중장기 미래에는 증가하는 것으로 나타났다. 기존 북한 수자원시설은 기후변화 영향에 취약하고, 신규 북한 수자원시설은 기후변화 영향에 유리하게 입지하고 있는 것으로 판단된다.

Anticorrosive Monitoring and Complex Diagnostics of Corrosion-Technical Condition of Main Oil Pipelines in Russia

  • Kosterina, M.;Artemeva, S.;Komarov, M.;Vjunitsky, I.;Pritula, V.
    • Corrosion Science and Technology
    • /
    • 제7권4호
    • /
    • pp.208-211
    • /
    • 2008
  • Safety operation of main pipelines is primarily provided by anticorrosive monitoring. Anticorrosive monitoring of oil pipeline transportation objects is based on results of complex corrosion inspections, analysis of basic data including design data, definition of a corrosion residual rate and diagnostic of general equipment's technical condition. All the abovementioned arrangements are regulated by normative documents. For diagnostics of corrosion-technical condition of oil pipeline transportation objects one presently uses different methods such as in-line inspection using devices with ultrasonic, magnetic or another detector, acoustic-emission diagnostics, electrometric survey, general external corrosion diagnostics and cameral processing of obtained data. Results of a complex of diagnostics give a possibility: $\cdot$ to arrange a pipeline's sectors according to a degree of corrosion danger; $\cdot$ to check up true condition of pipeline's metal; $\cdot$ to estimate technical condition and working ability of a system of anticorrosive protection. However such a control of corrosion technical condition of a main pipeline creates the appearance of estimation of a true degree of protection of an object if values of protective potential with resistive component are taken into consideration only. So in addition to corrosive technical diagnostics one must define a true residual corrosion rate taking into account protective action of electrochemical protection and true protection of a pipeline one must at times. Realized anticorrosive monitoring enables to take a reasonable decision about further operation of objects according to objects' residual life, variation of operation parameters, repair and dismantlement of objects.

상용2회선 수전방식을 적용한 무정전 수변전설비 구축방안 검토·제안연구 (Construction of Uninterruptible Power System by Reliable Incoming Dual-Power Line)

  • 최진성;이상중
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.64-70
    • /
    • 2010
  • High capacity UPS and emergency generators are commonly employed at facilities where power interruption is not allowed. Nowadays, combinations of existing commercial incoming power and an emergency generator or combination of multiple generators and CTTS(Closed Transition Transfer Switch) is adopted sometimes for more reliable power supply. In this paper, application of CTTS and STS(Static Transfer Switch) to dual-power line is suggested for highly reliable uninterruptible power. By realizing such a system, construction of incoming power facilities, installation of emergency generator and large capacity UPS can be omitted, through which saving of the installation space and corresponding capital investment can be expected.

전국 중학교 시설의 에너지 사용실태 분석 연구 (A Study on Analysis of Energy Consumption of the Middle School Facilities in Korea)

  • 윤종호;신우철;조진일;박재완;김효중
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.45-50
    • /
    • 2010
  • This study for middle school facilities is second following the study of the energy consumption of primary school facilities. There is not on the analysis of the current energy usage for middle school facilities in nations to set goals of energy reduction. Therefore, The purpose of this study is to present various analysis result of energy consumption which is a statistical analysis of domestic middle school facilities in South Korea. As a consequence, each average energy consumption at the domestic middle school facilities analyzed as following after changing as unit 'kWh' only for comparison with every energy source. It represents that the energy consumption of electric power was 183.7MWh(70.2%), gas consumption for heating was 46.5MWh(17.8%), oil consumption was 26.5MWh(10.1%), district energy was 5.1MWh(1.9%). This result describes that consumption of electric power was large greatly and it reflects the expectation that it will climb the demand regarding this energy in the future. In additionally, it analyzed average energy consumption with $74.4kWh/m^2$ by the unit area of air-conditioning and the district which has large energy consumption was Seoul with $91.6kWh/m^2$.

전력 설비 진단을 위한 IED 의 구현 (The Implementation of IED for Diagnosis of Electric Devices)

  • 오재훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1110-1111
    • /
    • 2007
  • These days, the concerns about maintenance and repair of electric facilities for stable and reliable electric power supply are increasing day by day. Because, we can have enormous damages economically and socially from a problem of the facilities, no matter how it is a small one. Especially, electric facilities in our country had been built abruptly from 40 years ago, so it can be thought that here are great amount of old facilities that must be repaired or replaced with new one, and the number would be increased time by time. On this situation, many researchers are studying the efficient and reliable method of maintenance for electric facilities and the results are applied on the facilities gradually by growing interests of operators and managers of the facilities. In this paper, the IED(Intelligent Electronic Devices) for Diagnosis system of electric machines are described. It takes analog data from a sensing device and operates digital processor to get a optimum digital data for diagnosis system. Now, this device is applied on several high voltage substations to diagnose and maintain GIS. Brief schematic of total diagnosis system and the construction of the IED are included in this paper.

  • PDF

배전용 변압기의 합리적인 사양과 그 설계법 (The optimum specifications and design of distributive transformers)

  • 이승원
    • 전기의세계
    • /
    • 제14권4호
    • /
    • pp.8-17
    • /
    • 1965
  • Firstly, this study has analyzed the following factors affecting the optimum specifications and design of distributive transformers: 1. Facilities installation cost per unit power output. 2. Facilities operating & maintenance cost per unit power output. 3. Production cost per unit power output. 4. Load factor. 5. Loss factor. Secondly, it has clarified the relations between the following factors and the specifications and design of distributive transformers; 1. No-load loss., 2. Load loss., 3. Voltage regulation., 4. Exciting current. Finally, it has determined the method of the most economic design for the transformers using the above factors and relations, and, for optimum the illustrative purpose, suggested their optimum specifications, way of evaluation, and merits by means of typical example.

  • PDF

검침데이터를 이용한 전력설비 시공간 부하분석모델 (Spatio-temporal Load Analysis Model for Power Facilities using Meter Reading Data)

  • 신진호;김영일;이봉재;양일권;류근호
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1910-1915
    • /
    • 2008
  • The load analysis for the distribution system and facilities has relied on measurement equipment. Moreover, load monitoring incurs huge costs in terms of installation and maintenance. This paper presents a new model to analyze wherein facilities load under a feeder every 15 minutes using meter reading data that can be obtained from a power consumer every 15 minute or a month even without setting up any measuring equipment. After the data warehouse is constructed by interfacing the legacy system required for the load calculation, the relationship between the distribution system and the power consumer is established. Once the load pattern is forecasted by applying clustering and classification algorithm of temporal data mining techniques for the power customer who is not involved in Automatic Meter Reading(AMR), a single-line diagram per feeder is created, and power flow calculation is executed. The calculation result is analyzed using various temporal and spatial analysis methods such as Internet Geographic Information System(GIS), single-line diagram, and Online Analytical Processing (OLAP).