• 제목/요약/키워드: Power facilities

검색결과 2,003건 처리시간 0.029초

765kV 변전소 지진계측시스템 구축과 관측자료 예비분석 (765kV Substations Earthquake Monitoring System and Preliminary Data Analysis)

  • 박동희;연관희;서용표;김병철
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.56-63
    • /
    • 2006
  • Facilities of 76skV Substation(S/S) play an important role in electric power supply grids. Various power facilities of 765kV S/S might be damaged enormously if a strong earthquake occurs. In an effort to mitigate possible earthquake disasters, KEPRI (Korea Electric Power Research Institute) set forth plans to verify seismic safety of the facilities of 765kV S/S. To accomplish the task, an earthquake monitoring systems is constructed at four 765kV S/S sites(Shin-AnSung, Shin-TaeBaek, Shin-SeoSan and Shin-GaPyung). Data from these earthquake monitoring stations are being transmitted via satellite communication. Currently, KEPRI is operating an earthquake monitoring system in freefield of Shin-SeoSan S/S (NSS) tentatively, Also, the data from NSS is preliminarily analyzed using the horizontal to vertical (H/V) spectrum ratio method. The method of H/V spectrum ratio has been used to infer site amplification without previous knowledge of near surface geology. The results of data analysis shorts good S/N ratio and amplification of 20-25 Hz by site effect. In the near future, the accumulated data is expected to provide a basis for assessing and predicting any damages to integrity of 765kV S/S facilities by earthquakes.

  • PDF

방사성 액체폐기물 처리 시설 내 공기오염에 의한 작업종사자 방사선학적 영향 평가에 대한 연구 (A Study on the Evaluation of Radiological Effects on Workers from Air Contamination in Radioactive Waste Treatment Facilities)

  • 이민호;하우범;이상헌;송종순
    • 방사선산업학회지
    • /
    • 제18권2호
    • /
    • pp.147-153
    • /
    • 2024
  • Radioactive liquid waste generated during operation and overhaul is collected and reused through the radioactive liquid waste treatment system and continuous monitoring system in the nuclear power plant or discharged to the outside if it satisfies the limit within the control and monitoring. However, there are concerns about boric acid management, which controls the power output of nuclear power plants in radioactive liquid waste. Due to the behavior of boric acid, it is difficult to remove it in the existing liquid radwaste system, and the concentration of boric acid water discharged tends to be higher than the natural state of 5 ppm, so additional facilities should be considered. Therefore, this study aims to evaluate the radiological effects of radioactive waste treatment facilities that are under development and use them as a basis for managing worker exposure and evaluating the safety of facilities in the future.

경수로 사용후핵연료 중간저장시설 개념(안) 수립 (Conceptual Design of Interim Storage Facility for PWR Spent Nuclear Fuel)

  • 강현구;이상환;신창민;문태철
    • 방사선산업학회지
    • /
    • 제18권3호
    • /
    • pp.255-266
    • /
    • 2024
  • The uranium nuclear fuel used in nuclear power generation needs to be replaced with new fuel after a certain period. In South Korea, the spent nuclear fuel generated during this process is temporarily stored within the nuclear power plant site, and there are ongoing issues with the saturation of storage capacity. To address these problems, the South Korea government has established a plan to manage high-level radioactive waste, including provisions for securing interim storage facilities. An interim storage facility is designed to safely store spent nuclear fuel for certain period before its permanent disposal. This study analyzed leading international cases of interim storage facilities that are technically feasible and can reduce the operating period of temporary storage facilities for spent nuclear fuel within nuclear power plant sites. It also presented the technical concepts required for the operation of interim storage facilities for spent fuel from PWR(Pressurized Water Reactor), reflecting the situation in South Korea.

수동대기모드를 고려한 셋톱박스 모드전환 기술의 에너지 절감 성능 분석 (Power consumption evaluation of Set-top box mode transition scheme considering passive stand-by mode)

  • 김용호;김훈
    • 정보통신설비학회논문지
    • /
    • 제10권4호
    • /
    • pp.135-142
    • /
    • 2011
  • This paper proposes a performance evaluation method for power consumption of set-top box (STB) stand-by mode transition schemes. A stand-by mode transition scheme characterizes the timing of mode transition. The timing of mode transition affects the duration of stand-by mode operation, and the power consumptions of STB as well. Recently a fast stand-by mode transition scheme (FMT) has been proposed based on user input for selecting the device to be connected to TV. In this paper, we evaluate power consumption of FMT and a conventional mode transition scheme. For the computation of the duration of stand-by mode operation, the user input events are modeled as Poisson process. Simulation results based on the modeling reveals that the proposed scheme is more effective in power saving than the conventional scheme by up to 30%.

  • PDF

철도 차량용 보조전원장치의 병렬 운전을 위한 가상 임피던스 기반의 드룹 제어 (A Modified Droop Control Method for Parallel Operation in Railway Auxiliary Power Supply Based on Virtual Impedance)

  • 안창균;최봉연;강진욱;강경민;이훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.342-343
    • /
    • 2019
  • This paper explores the power distribution problem of parallel-connected inverter system which supplies auxiliary power for railway facilities. We propose a droop control method which facilities power distribution and restrain of voltage drop by tracking the average power control command by adjusting the virtual impedance. The performance of proposed droop method is verified by the PSIM simulation.

  • PDF

단상 AC Line 호환형 대용량 전원 장치 구현 방안 (Universal Single-Phase Line Compatible High Power AC/DC Converter)

  • 김병석;강경수;노정욱
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.297-304
    • /
    • 2015
  • A conventional single-phase high-power system typically generates a large AC line input current at universal 90 VAC condition. Sometimes, this phenomenon can block the Earth Leakage Circuit Breaker (ELCB), which causes problems. Replacing power facilities is essential to ensure smooth operations. Thus, this paper proposes a method that can drive higher power than the limit of conventional power facilities. The proposed method can reduce the large AC line input current by limiting the input power of Power Factor Correction (PFC). An additional battery circuit can supplement the power deficiency. Specifically, a bidirectional converter with charging and discharging functions was adopted for the battery circuit. Finally, the validity of the proposed system could be confirmed by modal analysis and simulation, and an experiment in 2 KW condition was implemented with a prototype sample as well.

발전구조물의 자산관리 시스템 구축을 위한 시설물분류체계 활용방안에 관한 연구 (A Study on the Application Method of Facility Classification System for the Development of Asset Management System for Power Generation Structures)

  • 전석현;정정식;안진희;김창학
    • 한국건설관리학회논문집
    • /
    • 제20권2호
    • /
    • pp.113-118
    • /
    • 2019
  • 최근 시설물의 관리를 위한 유지관리는 기존 시설물의 안전진단 등을 통한 구조물의 안정성 위주의 관리에서 시설물의 성능을 평가하여 관리하는 자산관리 개념으로 추세가 바뀌어 가고 있다. 시설물의 자산관리를 위해서는 시설물의 유지관리 및 서비스수준을 평가하고 이를 관리하기 위한 정보 분류가 효율적으로 이루어 져야 한다. 발전 시설물의 경우 복합구조물로 매우 복잡한 형식으로 구성되어 있다. 따라서 본 연구에서 국내 통합 건설분류체계 형식을 반영하여 발전 시설물을 시설, 공간, 부위, 요소로 구분하고 보일러 건물을 사례로 하여 분류를 실시하였다. 본 분류체계는 시설물의 환경조건 등을 반영한 열화조건을 반영하기 위해서 기존의 분류체계에서는 볼 수 없는 방향, 내부, 외부 등을 추가하여 분류하였다. 이는 발전구조물의 특성상 해안가에 위치하고 비례 염분 및 습도 등의 환경조건에 따라 열화속도를 반영하여 체계적이고 효율적인 유지관리를 할 수 있도록 한 것이다. 본 연구에서 개발된 분류체계는 발전시설물의 자산관리를 위한 전산시스템개발에 기초적인 자료로 활용되게 될 것이다.

운전 중인 상태에 있는 22kV 전송선로 케이블의 열화 과정해석에 대한 연구 (A Study on the Deterioration Process of 22kV Power Cables in Operation)

  • 이관우;엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.127-133
    • /
    • 2013
  • 산업사회의 발전에 필수적인 요소 중의 하나로서, 전력 에너지의 수요는 과학 기술의 발전에 따라 꾸준히 증가해오고 있다. 전력의 수요에 부응하기 위해, 고전압과 대용량을 감당할 전력설비기 필요하다. 튼튼한 바탕 위에서 전력을 생산 공급하기 위해서는 전기 시설은 신뢰성 있게 운전해야 한다. 전력 설비가 사고를 일으킬 경우 막대한 국가적 손실을 초래하게 된다. 국가 기간 산업 시설의 중추적인 기능을 하고 있는 전력 설비는 가능한 안정된 상태를 유지하면서 오랜 기간 동안 운전할 수 있어야 하며, 사고를 미리 예방할 수 있어야 한다. 전력을 전달하기 위한 수단으로서 사용되고 있는 케이블 설계 시 수명을 약 30년으로 간주하지만, 많은 경우의 실제 현장에서는 8~12년 정도에서 파괴 현상이 발생하여 재산상의 큰 피해를 초래한다. 본 논문은 운전 중 22kV 케이블 시스템의 열화 과정에 대한 연구를 통하여 열화의 원인을 파악하였으며, 와이블 분포만 따르는 것이 아니라 열열화 후 와이블 열화를 거쳐 부분 방전에 의하여 케이블이 파괴되는 것을 확인 할 수 있었다.

1Cr1Mo1/4V 터빈 로터강의 크리프 손상 모델에 관한 연구 (Study on Creep Damage Model of 1Cr1Mo1/4V Steel for Turbine Rotor)

  • 최우성;에릭플러리;송기욱;김범신;장성호
    • 대한기계학회논문집A
    • /
    • 제35권4호
    • /
    • pp.447-452
    • /
    • 2011
  • 일반적으로 화력발전 터빈 로터나 케이싱과 같이 고온 고압에서 운전되는 설비의 경우 크리프 및 피로 손상이 주된 손상기구로 알려져 있다. 터빈 설비의 수명을 정확하게 예측하기 위해서 크리프 및 피로 손상 기구를 복합적으로 고려해야 하지만 500MW 급 대용량 터빈 설비의 경우 기저 부하를 담당하기 때문에 기동횟수가 많지 않고 고온에서 장시간 동안 안정적인 운전을 하므로 잔여수명을 결정할 때 크리프 수명을 주로 사용한다. 국내에서 20 년 넘게 운전되고 있는 대용량 터빈의 경우 대부분 니켈, 크롬, 몰리브덴, 바나듐 성분이 포함한 재료로 되어 있다. 본 논문에서는 대용량 터빈의 크리프 수명을 예측하기 위하여 1Cr1Mo1/4V 터빈 로터강에 대한 크리프 손상 모델을 제안하고자 한다.

강재 전력시설물을 위한 액상 규산질 도장제 개발에 대한 연구 (Development of Fluid Silicic Acid Coating with Paint Materials of the Steel Electric Power Facilities)

  • 권성준;박상순;이상민;이명훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.57-64
    • /
    • 2008
  • 일반적으로 강재시설물에 사용되는 유기에폭시 도장의 경우, 일반적인 조건에서는 우수한 내구성을 보이고 있으나, 송/배전 시설물인 강재전력시설물과 같이 빛(자외선)이나 열에 노출되는 환경에서는 도막자체의 열화현상에 의한 피해가 더욱 심각하게 증가하고 있다. 본 연구의 목적은 무기계 액상 규산질을 기초로 한 강재용 도장제를 개발하는 것이다. 이를 위해 6가지 예비실험을 거쳐서 최적의 배합조건을 도출하였으며, 물리적 특성실험 및 내구성 실험을 수행하였다. 실험결과 개발된 무기계 도료는 현재의 유기계 도료의 성능을 확보하고 있었으며, 내화학성에 대한 저항성이 개선된다면, 강재 시설물의 대체 도료로 사용될 수 있으며, 그 적용성이 더욱 증가할 것으로 평가되었다.