• 제목/요약/키워드: Power equipment

검색결과 4,046건 처리시간 0.14초

VVVF기를 기초한 가변식기압급수설비의 자동제어 문제 (Automatic control problems of VVVF converter-based variable-frequency type air)

  • 박용규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.468-468
    • /
    • 1991
  • The variable-frequency type water supply equipment, which adopts the variable-voltage and variable-frequency converter(VVVF converter) to govern automatically the rotating speed of a pump, can save 15-20% of power, as compared with a throttle-controlled pump device or an airpressurized water supply equipment, and is finding a wide application. However, it still has some disadvantages : greater pressure fluctuations during switching over the pump and prolonged low-effeciency running of the pump in the case of small consumption of water. Therefore, it is difficult to apply the equipment to the fire water supply system where the water should not be put into use unless a fire takes place, and the water pressure in pipelines should permanently remain constant. This paper introduces the automatic regulation principle of the variable-frequency type air-pressurized water supply equipment (hereafter referred to as simply BFQS equipment) for dual purposes of daily life and fire control, which combined both technologies of speed governing by a converter and air-pressurized water supplying, then discusses some problems related to automatic control, and finally gives the experimental results of an embodiment-BPQS-100-50 water supply equipment.

  • PDF

대형 레이더 수송용 이동치구의 주행동특성 분석 (Analysis for the Dynamic Characteristics of the Moving Equipment for the large Radar Transportation)

  • 전종익;이종학;강영식;최지호;강동석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.416-421
    • /
    • 2013
  • In this paper, the design concept of the transport of defense equipment and processes were established. And the transport of large radar equipment design were investigated. Detailed design of moving equipment with reference to the U.S. military standard was performed.Damping system of the moving equipment by using a simulation designed to predict In order to minimize shock and vibration in the vehicle due to the irregular road surface is transmitted through. Analysis of the damping system was verified using the driving test.

  • PDF

광음향 분광법을 이용한 휴대용 유중가스분석장치 개발 (Development of Portable Dissolved Gas Analyzer Using photoacoustic spectroscopy)

  • 김춘동;김철규;박세현
    • 한국정보통신학회논문지
    • /
    • 제17권10호
    • /
    • pp.2431-2438
    • /
    • 2013
  • 본 논문에서는 휴대용 유중가스 분석기에 대해 연구 및 개발 하였다. 제안된 휴대용 유중가스 분석기는 전력기기로부터 절연유 내의 소량의 가스를 추출하여 비정상적인 열적 정보를 얻어 분석하는데 유용하게 쓰인다. 분석된 정보로부터 전력기기의 안정성을 평가할 수 있다. 본 논문에서는 기존의 고가의 시설기반의 고정형 유중 가스 분석기를 사용함으로써 발생되는 직간접적인 문제점을 해결하기 위해서 광음향 분광법 기반의 소형화된 휴대용 유중가스 분석기를 제안하고 실험적으로 검토하였다. 제안된 휴대용 유중 가스 분석기는 사용하기 편하고 실시간으로 전력기기의 열적 정보를 분석할 수 있다. 제안된 휴대용 유중가스 분석기가 현재의 전력기기 유중가스 분석에 사용된다면, 전력기기의 유중가스 분석주기를 줄임으로써 안정성을 향상 시키고 열적 이상 정보에 대하여 긴밀하게 대응할 수 있다.

수변전실 및 지상 전력기기 침수방지 대책에 관한 연구 (Countermeasures for Flood Protection of Power Facility at Substation and Ground)

  • 김기현;최명일;배석명;이재용
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.78-84
    • /
    • 2008
  • 매년 집중 호우 및 태풍 해일 등에 의해 도심 저지대 및 해안가 지대 수변전실 및 지상 전력기기의 침수 현상이 매년 발생하고 있다. 그로 인한 설비 교체 비용 및 정전으로 인한 사회, 경제적 손실이 더욱 크게 발생을 하고 있다. 또한 국내 환경 변화로 전기설비 침수 발생 빈도는 증가될 것으로 판단된다. 따라서 국내 수변전실 및 지상 전력기기의 설치 현황과 침수 피해에 대해 실태조사 및 국내외 관련 제도를 분석하였다. 분석 결과 국내의 침수방지 대책이 현장 시설 부분과 제도적으로 미비한 것을 확인 할 수 있었다. 본 논문은 현장실태조사 결과와 국외 침수방지대책에 관한 규정 분석을 토대로 침수위험지구에서의 전력기기 침수방지 대책을 위한 내용을 제시하였다. 또한 본 내용은 국내 관련 규정을 개정하는데 객관적 자료로 사용될 것으로 사료된다.

GIS 부분방전 신호와 도착 시간차 분석을 통한 PD발생 위치 추적 (Partial Discharge Position Tracking Method using a GIS Partial Discharge Signal and Arrival Time Difference)

  • 최문규;차한주
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1297-1301
    • /
    • 2013
  • This paper analyzes of PD occurrence position through an analysis of the arrival time difference between the GIS partial discharge signal. Because of GIS (Gas Insulated Switchgear) is a facility very important power equipment and as part of the equipment that make up the power system, the stabilization of the power industry, which accounted for 88.5% share of GIS substation in the form of a substation is an important equipment for power supply. In the situation where we are gradually expanding the need for preventive diagnosis in order to improve the efficiency of equipment management and failure prevention for Preventive diagnosis. In this paper as a method for extracting pre-defect of failure of GIS Apply the average value method of calculating the 5 times each using a pulse of the first time of the second pulse (${\Delta}t$) with an oscilloscope generation position PD(Partial Discharge). the results of GIS internal inspection, the partial discharge of the actual the position of the partial discharge was confirmed with an accuracy of about 82% of positions. Arrival time difference in the most effective manner if the partial discharge of GIS internal occurs by applying the averaging method and TOA(Time of arrival) method, the partial discharge occurs you through the measurement and analysis of PD signal occurs was confirmed in the experiment are presented and diagnostic methods location tracking.

Influence of Electrical Aging on Space Charge Dynamics of Oil-Impregnated Paper Insulation under AC-DC Combined Voltages

  • Wang, Yan;Li, Jian;Wu, Sicheng;Sun, Peng
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1512-1519
    • /
    • 2013
  • Oil-impregnated paper is a major type of insulation used in oil-filled converter transformers for both traditional and new energy systems. This paper presents and analyzes the results of the experiment conducted on the electrical aging of oil-impregnated paper under AC-DC combined voltages using the pulsed electro-acoustic (PEA) technique. The formation and dynamics of space charge affected the performance of insulation material. The electrical aged oil-paper insulation was obtained through electrical aged experiments under the voltages. Based on the PEA technique, measurements were carried out when the oil-paper insulation system was subjected to different stressing and aging times. The space charge dynamics in the bulk of the oil-paper insulation system with different aging times were measured and analyzed. Characteristic parameters such as the total charge injection amount, the total charges of fast moving and slow moving, and the distortion factor of electric field were calculated and discussed. Results show that the longer electrical aging time, the more charges trapped in the bulk of aging sample. It leads to larger distortion factor of electric field in the bulk of aging samples and accelerate degradation of oil-paper insulation under AC-DC combined voltages.

기기의 지진취약도 평가를 위한 구조물 비탄성구조응답계수의 재평가 (Revaluation of Inelastic Structural Response Factor for Seismic Fragility Evaluation of Equipment)

  • 박준희;최인길
    • 한국전산구조공학회논문집
    • /
    • 제28권3호
    • /
    • pp.241-248
    • /
    • 2015
  • 원자력발전소에는 전력생산과 안전과 관련된 수많은 기기들이 존재하고 있다. 기본적으로 원자력발전소의 구조물과 기기는 지진시 탄성거동올 목표로 안전율을 매우 높게 적용하여 설계해 왔다. 그러나 최근 발생한 지진의 규모가 증가함에 따라 설계수준을 초과한 지진에 대한 기기의 안전성을 재평가할 필요가 있다. 본 연구에서는 구조물의 비선형 거동에 의한 층응답을 분석하였고, 비선형해석에 의한 구조물의 비탄성구조응답계수를 재평가하였다. 기기의 지진취약도 평가시 구조물의 비탄성구조응답이 어떤 영향을 주는지 분석하기 위하여 재평가된 구조물의 비탄성구조응답계수와 기존에 사용되어온 구조물 비탄성구조응답계수를 적용하여 지진취약도 평가를 수행하였다. 해석결과에 따르면 비탄성구조응답계수는 기기의 고유진동수, 기기의 위치 그리고 구조물의 동특성에 따라 영향을 받는 것으로 나타났다.

배전설비 결함 검출을 위한 초음파 음원 위치추정 및 시각화 기법 (Ultrasonic Source Localization and Visualization Technique for Fault Detection of a Power Distribution Equipment)

  • 박진하;정하형;유준
    • 제어로봇시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.315-320
    • /
    • 2015
  • This paper describes the implemenation of localization and visualization scheme to find out an ultrasonic source caused by defects of a power distribution line equipment. To increase the fault detection performance, $2{\times}4$ sensor array is configured with MEMS ultrasonic sensors, and from the sensor signals aquired, the azimuth and elevation angles of the ultrasonic source is estimated based on the delay-sum beam forming method. Also, to visualize the estimated location, it is marked on the background image. Experimental results show applicability of the present technique.

4WD 및 4WS이 가능한 로더 개발(I) (4륜 구동 변속기) (development of Loader Equipped with 4WD and 4WS (I) (4 Wheel Driving Transmission))

  • 조현덕
    • 한국생산제조학회지
    • /
    • 제7권6호
    • /
    • pp.141-148
    • /
    • 1998
  • A loader is construction & road or agricultural machinery for lifting, moving, and mixing. This study deals with the agricultural mini loader for stock raising farming. The performance of the machine is established by pulling power, working lifting capacity, and minimum circling radius, etc. Also, driving easiness and endurance are very important in manufacturing. Thus, this study has developed the loader with the 4-wheel driving equipment by gear transmission, the 4-wheel steering equipment by power handle steering type, and the equipment making four wheels touch simultaneously on the rugged ground. The developed loader having these functions was very fit in a small cattle shed or a rugged ground. This study is divided into two parts; (I) development of 4WS transmission and (II) construction of the loader by 4WS system and other equipments.

  • PDF

화력발전소 통합감시제어시스템의 기기검증시험 사례 분석 (Anaysis of Equipment Qualification Tests for IMCS(Integrated Monitoring & Control System) in Thermal Power Plants)

  • 신만수;이주현;박두용;변승현;최인규;이세경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1820-1821
    • /
    • 2011
  • The equipment qualification test was accomplished before application to power generating stations because troubles in applying to real system could be prevented trough the test. That is, if a system was judged to be suitable in the equipment qualification test, the system was expected to be operated stable to the designed life.

  • PDF