Comparative Study of DC Breakdown and Space Charge Characteristics of Insulation Paper Impregnated with Natural Ester and Mineral Oil

  • Hao, Jian;Zou, Run-Hao;Liao, Rui-Jin;Yang, Li-Jun;Liao, Qiang;Zhu, Meng-Zhao
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1682-1691
    • /
    • 2018
  • Natural ester is a suitable substitute for mineral oil and has been widely used in AC transformer in many countries. In order to further application of natural ester in direct current (DC) equipment, it is needed to investigate its long term insulation property under DC condition. In this paper, a thermal ageing experiment was conducted for both mineral oil-paper and natural ester-paper insulation. The DC breakdown and space charge characteristics of insulation paper impregnated with natural ester and mineral oil was compared. Results show that the resistivity of the paper immersed in natural ester and mineral oil both increase as the ageing goes on. While insulation paper impregnated with natural ester has higher resistivity and DC breakdown voltage than the paper impregnated with mineral oil. The DC breakdown voltage for the oil impregnated insulation paper being DC pre-stressing is higher than that without pre-stressing. The average DC breakdown field strength difference between the test with pre-stressing and without pre-stressing clearly shows that there is an apparent enhancement effect for the homo-charge injection on the DC breakdown.

전력 유도 장애 시 통신 선로 케이블의 접지체와 유도원간의 이격거리에 의한 유도 잡음 영향 분석 (Analysis on the Effects of the Induced Noise with Change of the Separation Distance between Grounding Equipment at End of Telecommunication Line and the Inducting Facilities in Power Inducting Situation)

  • 최문환;이상무;조평동
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.215-218
    • /
    • 2007
  • In this paper, we have analyzed the effects from the change of separation distance between grounding equipment at end of telecommunication line and the inducting facilities in power inducting situation. In the result of measurement, we can see that as the separation distance between grounding equipment ant end of telecommunication line and the inducting facility become longer, the induced noise level and PIF level is decreased. From the another experiment results about the effect of changing the impedance size in both ends of telecommunication line, however, we already knew that as the ground impedance at either end of the telecommunication line become grower, the noise level is increased, and as the ground impedance at either end of the telecommunication line become smaller, the noise level is decreased. Hence we can not define the relationship exactly between separation distance from inducting facility to inducted facility and the induced noise level because when the grounding equipment is moved, its impedance size is changed too. In conclusion, changing the separation distance between grounding equipment at end of telecommunication line and the inducting facilities have not influence on the induced noise level.

  • PDF

도시철도 전력설비 상태진단 통합시스템 현장구현 (Urban Rail Power Facilities on-site Implementation of an Integrated System Diagnosis)

  • 임형길;이병두;김용덕;장순호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2015-2020
    • /
    • 2011
  • Key set the current non-urban rail power failure of equipment to operate the railway will generate a lot of problems. I know in advance the ideal of power equipment to prevent the failure to derive an efficient replacement cycle for the power equipment monitoring and diagnosis of the condition can become necessary to develop a system. In order to determine the status of the power plant during operation and behavior of the partial discharge current state data, regular monitoring and inspection requirements also stamp the basic current, voltage, temperature and humidity should be identified.

  • PDF

원전 방진기 검사 및 관리 현황 (Status of Inspection and Management for Nuclear Power Plants Snubbers)

  • 조용배;문균영;유현주
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.20-24
    • /
    • 2014
  • Recently, it is getting more and more important ensuring the integrity for the equipment degradation according to the increase of nuclear power plant operating period. In many equipment of the nuclear power plant, snubbers mainly installed in reactor coolant pumps, steam generators and piping protected the equipment and piping from the occurrence of transient dynamic loads such as the earthquake, thermal load during the plant operation. This report describes the function, regulation, inspection requirements and management status of the snubbers installed in domestic nuclear power plants.

전력품질로 인한 아파트 수용가 승강기의 전기적 설비 영향에 관한 연구 (A Study on electrical equipment effect of apartment customer elevator by power quality)

  • 이희태;김재철;강장규;김기현;설규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.304-305
    • /
    • 2006
  • Now there is utilization of elevator increasing continuously, it is one of electrical facilities taking a serious view safety. However, elevator comfortable ride is researched generally Recently aging condition, equipment life, malfunction, other applicancies of power electronics and equipment disturbance effect on power quality and prevention measures are much researches in advanced nation. but awareness is lacking real condition up to now in domestic. Voltage sag, swell, harmonics, surge etc of elevator system is important problem about human safety. and there are many quality compensation to solve these problem of elevator. So to evaluate these problem, in this paper, displayed result through computer simulation for converter of problem, and inverter part by power quality problem in power distribution system.

  • PDF

데이터센터의 공조시스템 계획을 위한 IT장비의 전력 및 발열량 예측에 대한 연구 (Power and Heat Load of IT Equipment Projections for New Data Center's HVAC System Design)

  • 조진균;신승호
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.212-217
    • /
    • 2012
  • The cooling of data centers has emerged as a significant challenge as the density of IT equipment increased. With the rapid increasing of heat load and cooling system, predictions for electronics power trends have been closely watched. A data center power density projection is needed so that IT organizations can develop data centers with adequate cooling for reasonable lifetimes. This paper will discuss the need for something more than processor and equipment power trend projections which have overestimated the required infrastructure for customers. This projection will use data from a survey of actual enterprise data centers and the ASHRAE projections to formulate a data center server heat load trend projection.

중앙 냉방시스템의 전력량 요금절감을 위한 디맨드제어 적용방안 연구 (Demand Control Application Strategies for Saving Electric Power Price of Central Cooling System)

  • 황진원;송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2012
  • In this study, computer simulation for demand control strategies to save the electric energy and power price in the building central cooling system is done. The demand control and outdoor reset control algorithms are applied by consideration the electric energy and power price according to the energy consumption characteristics. The suggested control methods show better responses in the power price and energy consumption in comparison with the conventional one.

Leg-Balancing Control of the DC-link Voltage for Modular Multilevel Converters

  • Du, Sixing;Liu, Jinjun;Lin, Jiliang
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.739-747
    • /
    • 2012
  • This paper applies carrier phase shifted pulse-width modulation (CPS-PWM) to transformerless modular multilevel converters (MMC) to improve the output spectrum. Because the MMC topology is characterized by the double-star connection of six legs consisting of cascaded modular chopper cells with floating capacitors, the balance control of the DC-link capacitor voltage is essential for safe operation. This paper presents a leg-balancing control strategy to achieve DC-link voltage balance under all operating conditions. This strategy based on circulating current decoupling control focused on DC-link balancing between the upper and lower legs in each phase pair by considering the six legs as three independent phase-pairs. Experiments are implemented on a 100-V 3-kVA downscaled prototype. The experimental results show that the proposed leg-balancing control is both effective and practical.

Quasi-renewal 이론을 이용한 발전설비의 불완전한 유지보수 예방정비 계획 (Imperfect Preventive Maintenance Plan of Generation Unit Using Quasi-renewal Theory)

  • 김형준;변융태;김진오;이준경
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.735-740
    • /
    • 2008
  • Recently, the research of PM (Preventive Maintenance) method on the RCM(Reliability-Centered Maintenance) of the system equipment is being actively advanced for a few years. For the most of the current power equipment maintenance, the state of the equipment after maintenance is assumed to be becoming 'as good as new ones' state. However, the state of the power equipment is maintained like the states of the between 'as good as new ones' and 'as bad as old ones' by imperfect maintenance that implies the life decrease of the equipment by frequent breakdown, the error of maintenance process, and so on. So, the Maintenance method considering the real case has to reflect Imperfect maintenance than perfect maintenance. This paper suggests the Preventive Maintenance method by using Quasi - Renewal Theory for the gas turbine equipment as deliberating the imperfect maintenance for the real cases.

원자력발전소 주제어실 공기조화계통 기능적설비그룹 개발 (FEG Development of MCR HVAC System for NPP)

  • 현진우
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.21-25
    • /
    • 2012
  • Functional Equipment Group(FEG) of Nuclear Power Plant(NPP) is the bundling of multiple equipment subcomponents around a major equipment with a common system isolation characteristic or out-of-service consideration. The main purpose of FEG is to reduce out-of-service time to enhance maintenance effectiveness. KHNP(Korea hydro & Nuclear Power Co.) needs to develop these FEGs to successfully perform On-line Maintenance(OLM) which will be expected to institute in the future. Recently, there has been growing interest in OLM in KHNP. The aim of this paper is to suggest the way of FEG development and to build the FEG of MCR(Main Control Room) HVAC(Heat, Ventilation and Air Conditioning) system. The results of this study might be make good use of OLM and be helpful for equipment maintenance for MCR HVAC system.