• Title/Summary/Keyword: Power Saving Mode

Search Result 125, Processing Time 0.023 seconds

Dual Mode Phase-Shifted ZVS-PWM Series Load Resonant High-Frequency Inverter for Induction Heating Super Heated Steamer

  • Hisayuki Sugimura;Hidekazu Muraoka;Tarek Ahmed;Srawouth Chandhaket;Eiji Hiraki;Mutsuo Nakaoka;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.138-151
    • /
    • 2004
  • In this paper, a constant frequency phase shifting PWM-controlled voltage source full bridge-type series load resonant high-frequency inverter using the $4^{th}$ generation IGBT power modules is presented for innovative consumer electromagnetic induction heating applications, such as a hot water producer, steamer and super heated steamer. The bridge arm side link passive capacitive snubbers in parallel with each power semiconductor device and AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is evaluated and discussed on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency inverter topology, what is called, DE class type, including the variable-power variable-frequency regulation function can expand zero voltage soft switching commutation area even under low output power setting ranges, which is more suitable and acceptable for newly developed induction heated dual pack fluid heaters. Furthermore, even the lower output power regulation mode of this high-frequency load resonant tank inverter circuit is verified so that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

Railway Switching Point Heating System Using the Photovoltaic-Wind Power Hybrid (태양광-풍력 하이브리드를 이용한 철도 선로전환기 융설 장치 구현)

  • Kim, Dae-Nyeon;Park, Han-Eol;Kim, Deok-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.136.1-136.1
    • /
    • 2011
  • This paper proposes the method to implement the railroad switching point heating system using the hybrid of the photovoltaic and wind power. The goal of the implementation of the railroad switching point heating system is to prevent freezing of the snow in the winter. The heating system of railway used to supply electricity through photovoltaic and wind power to prevent freezing. Hot wires of the railroad switching point heating system are used about 2kW of electric energy at the day. The electric energy of 2kW used the length of the hot wires about 3m. As the ON and/or OFF mode considering the tracks temperature and the ambient temperature, so the way the use of power-saving effect. In addition, the system can be used the railroad switching point heating system in winter and railway signal and street lights around the track in summer. In experiment, we acquired the power data according to time at the day of photovoltaic and wind power. We confirmed the temperature rise using the heating cable for 3m of $85^{\circ}C$, 30W/m. The temperature rise of the heating cable changes the temperature of $5^{\circ}C$ after 10 minutes and $11^{\circ}C$ after 10 minutes. We have confirmed the possibility of the railroad switching point heating system using the hybrid of the photovoltaic and wind power.

  • PDF

A Transmission Technique for Paging Indicator in OFDM-based Cellular Systems (OFDM 이동통신 시스템의 Paging Indicator 전송 방식)

  • Kim, Yeong-Jun;Yoo, Hyun-Il;Woo, Kyung-Soo;Lee, Hee-Soo;Cho, Yong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7A
    • /
    • pp.710-719
    • /
    • 2008
  • In this paper, a transmission technique of paging indicator (PI) on the existing preamble is proposed to reduce power consumption of the user equipment in idle mode for OFDM-based cellular systems. Compared with the PI transmission technique using the L1/L2 control channel, the PI transmission technique using preamble has advantages of not requiring additional overhead for PI transmission as well as reducing computational complexity for PI detection. Synchronization and PI detection techniques are descried for OFDM-based cellular systems, especially for mobile WiMAX systems. It is shown by computer simulation that the PI can be transmitted using the preamble (or common synch symbol) without affecting performances of synchronization and cell searching in mobile WiMAX systems.

AC Regeneratable Battery Charging and Discharging Test System (AC 회생이 가능한 배터리 충·방전 테스트 시스템)

  • Kim, Jun-Gu;Youn, Sun-Jae;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.99-106
    • /
    • 2012
  • In this paper, 15[kW] AC regenerative system for battery charging and discharging test is proposed. The regenerative system is able to regenerate surplus energy to the grid in discharging mode, and the inverter of the system can be operated as a converter to compensate scarce energy in charging mode. In case of the conventional DC charging and discharging system, the regenerative energy is consumed by a resistor. However, as the proposed system regenerates the surplus energy to the grid through using DC-AC inverter, the energy saving effect can be achieved. In this paper, 15[kW] battery charging and discharging system is developed, and the validity of the system is verified through simulation and experimental results.

Handoff Management for Mobile Devices in Hybrid Wireless Data Networks

  • Inayat Riaz;Aibara Reiji;Nishimura Kouji
    • Journal of Communications and Networks
    • /
    • v.7 no.1
    • /
    • pp.76-86
    • /
    • 2005
  • Today's wireless access networks consist of several tiers that overlap each other. Provisioning of real time undisrupted communication to mobile users, anywhere and anytime through these heterogeneous overlay networks, is a challenging task. We extend the end-to-end approach for the handoff management in hybrid wireless data network by designing a fully mobile-controlled handoff for mobile devices equipped with dual mode interfaces. By handoff, we mean switching the communication between interfaces connected to different subnets. This mobile-controlled handoff scheme reduces the service disruption time during both horizontal and vertical handoffs and does not require any modification in the access networks. We exploit the IP diversity created by the dual interfaces in the overlapping area by simultaneously connecting to different subnets and networks. Power saving is achieved by activating both interfaces only during the handoff period. The performance evaluation of the handoff is carried out by a simple mathematical analysis. The analysis shows that with proper network engineering, exploiting the speed of mobile node and overlapping area between subnets can reduce service disruption and power consumption during handoff significantly. We believe that with more powerful network interfaces our proposal of dual interfaces can be realized.

Networked Smart Plug System for Power Management of PC & Peripherals (PC와 주변기기의 전력 관리를 위한 네트워크 기반의 스마트 플러그 시스템)

  • Ryu, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2171-2176
    • /
    • 2012
  • PCs and its peripherals uses more power in standby mode even if they are not actually being used. In particular, PCs and its peripherals used in school and office, plugged in at all times during working hours, but not used much time, even if turned off consume a portion of the power. In this paper, we developed Networked Smart Plug for Power Management of PC & Peripherals which is consist of EMS, Smart Plug, PC Agent and Smart Phone App. for power saving of PC and a variety of peripheral devices in office or home, and evaluated the performance of the system.

Performance Evaluation on the Power Consumption of IEEE802.15.4e TSCH (IEEE802.15.4e TSCH의 소비전력에 대한 성능평가)

  • Kim, Dongwon;Youn, Mi-Hee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.1
    • /
    • pp.37-41
    • /
    • 2018
  • In this paper, we evaluate the power consumption of IEEE802.15.4e TSCH which uses the specific link scheduling scheme proposed in reference[1]. And we also compares it with the power consumption of conventional single channel IEEE802.15.4. The power consumption of IEEE802.15.4e TSCH is smaller than the conventional one under the any conditions of traffic. The reasons can be explained as the followings. Firstly, TSCH does not have backoff time because of using the collision free link scheduling. Secondly, there is the timing difference of MAC offset parameter between TSCH and conventional IEEE802.15.4 Lastly, the devices in TSCH mode sleep during the time slots which are not assigned to itself.

Development of High Reliability Monitoring and Control System for Platform Screen Door (승강장 스크린 도어(PSD)에 대한 고 신뢰성의 감시 및 제어 시스템 개발)

  • Kim, Jin-Sik;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.158-162
    • /
    • 2010
  • PSD is automatically opened and closed when subway train arrive on the station. This system was designed to control electric automatic system. These doors will provide passenger safety, energy saving and a good environment in subway. The monitoring and control systems of PSD are configured so that they can be operated in automatic mode in connection with ATO through the composite control panel in the station control room. The objective of this paper is to obtain high reliability that is essential for monitoring and control systems of PSD. The power supply is based on protection circuit using DC power bridge from two UPS. Also, stable communication system consists of CAN communication line redundancy and RF cross protection algorithm. Monitoring state display results show the validity of the proposed high reliability monitoring and control systems of PSD.

A Study of the Real-time Sensing by the Optical Current Sensor for GIS

  • Park, Won-Zoo;Kim, Yeong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.75-80
    • /
    • 2009
  • In this study, a Web server was constructed using LabVIEW's DataSocket, which makes possible acquisition, analysis, and saving in real time. The output value of the optical current sensor at the web server PC was measured and the output value was displayed using the Web browser of the client PC. DataSocket by LabVIEW makes the construction of a Web server easier than other languages and is compatible with other application programs. An optical current sensor was composed using a 1310 [nm] laser diode, and 9/125 [${\mu}m$] standard single mode optical fiber and was created to be a close type sensor. Data measurement using Web servers has the advantage of monitoring electric power systems at a great distance and can fuse IT technology and electric power systems. Also, this measurement uses inexpensive mounting and programming when compared to existing measurement equipment allowing the construction of a measurement system in any situation or surrounding.

A Study on Energy Saving of IMV Circuit using Pressure Feedback

  • Park, Hyoung Gyu;Nahian, Syed Abu;Anh, Kyoung Kwan
    • Journal of Drive and Control
    • /
    • v.13 no.4
    • /
    • pp.31-44
    • /
    • 2016
  • In recent hydraulic actuation systems, conventional hydraulic spool valves with pressure compensators are becoming less popular, after the introduction of the independent metering concept for valves. Within this concept, four valves are needed for actuating a single cylinder. Subsequently, this increases the freedom of controlling both chamber pressures of the cylinder, and it then provides for electronically-controlled pressure compensation facilities. Additionally, this has the potential to save valuable energy. The primary focus of this paper is to develop a new generation of hydraulic circuits using the independent metering valve (IMV). This configuration can function well as a conventional IMV circuit while providing better pressure control. We first describe the working principles of five distinct modes of the proposed IMV system. Then, mathematical models for each working mode are presented. Finally, we present numerical simulations that have been carried out to evaluate the system performance, in comparison with that of the conventional IMV configuration. The simulation results demonstrate that the performance of the new IMV configuration is superior to the conventional IMV system in terms of energy savings.