• Title/Summary/Keyword: Power Measurement

Search Result 4,626, Processing Time 0.031 seconds

A Study on Measurement and Analysis of Pilot Channel Power at CDMA Communication Network (CDMA통신망에서 파일롯 채널전력 측정 및 분석에 관한 연구)

  • Jeong, Ki-Hyeok;Ra, Keuk-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.6 s.360
    • /
    • pp.31-39
    • /
    • 2007
  • In this paper, a system for real-time or periodic measurement and analysis of RF parameters such as forward transmit power and pilot power in CDMA base station systems is proposed. Such RF characteristic parameter measurement can be prevented from system fault and used to achieve optimal service quality and maximum investment return through cell coverage expansion, subscriber capacity increase and so on. For forward power measurement, the local oscillator frequency for the detector is varied so that the transmit power for all channels can be measured. The channel power measurement can be used to analyze the variation in transmit power for changes in voice traffic. By comparing to forward $E_c/I_o$, the pilot channel power can be deducted, which can be used to determine uy degradation in transmit section modules such as the high dover amplifier. Since an accurate analysis of carefully measured data using the CDMA level detector must be made, the system is designed so that measurement errors due to changes in crest factor with modulation method can be overcome.

Online output power measurement of full-bridged MOS-FET RF power inverter operating at shortwave frequency

  • Suzuki, Taiju;Suyama, Tetsuji;Yamamoto, Tetsuya;Ikeda, Hiroaki;Yoshida, Hirofumi;Shinohara, Shigenobu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1920-1923
    • /
    • 1991
  • An online RF power measurement is needed for the full-bridged MOS-FET RF power inverter because the output current and/or voltage waveform is other than sinusoidal. In order to satisfy the requirement, the online measurement of the output power of this type of RF power inverter by the use of the PC-98 personal computer has been presented. The current and voltage waveforms are sensed by the digital oscilloscope probes so as to obtain the instantaeous power and they are entered into the PC98 personal computer so as to average the instantaneous powers. The RF power of up to 1 kw at 1 MHz measured for the power inverter at the output transformer. This method was confirmed to be applied to evaluate the load resistance change with temperature.

  • PDF

A Substation-Oriented Approach to Optimal Phasor Measurement Units Placement

  • Bao, Wei;Guo, Rui-Peng;Han, Zhen-Xiang;Chen, Li-Yue;Lu, Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.18-29
    • /
    • 2015
  • State Estimation (SE) is the basis of a variety of advanced applications used in most modern power systems. An SE problem formed with enough phasor measurement units (PMUs) data is simply a linear weighted least squares problem requiring no iterations. Thus, designing a minimum-cost placement of PMUs that guarantees observability of a power system becomes a worthy challenge. This paper proposes an equivalent integer linear programming method for substation-oriented optimal PMU placement (SOOPP). The proposed method uses an exhaustive search to determine a globally optimal solution representing the best PMU placement for that particular power system. To obtain a more comprehensive model, contingencies and the limitation of the number of PMU measurement channels are considered and embodied in the model as changes to the original constraints and as additional constraints. The proposed method is examined for applicability using the IEEE 14-bus, 118-bus and 300-bus test systems. The comparison between SOOPP results and results obtained by other methods reveals the excellence of SOOPP. Furthermore, practical large-scale power systems are also successfully analyzed using SOOPP.

The Development of Prototype Synchronized Phasor Measurement Device for Real-time Power System Monitoring (전력계통 실시간 감시를 위한 동기위상측정장치의 시작품 개발)

  • 김학만;전진홍;김종율;남기영
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.230-236
    • /
    • 2002
  • In real-time power system control, it is essential to measure the power system variables which are voltage, current, real and reactive power, power factor, system frequency and etc. These variables can be estimated or calculated by the synchronized phasor informations of voltage and current. Therefore, the synchronized phasor measurement of voltage and current is very important to real-time power system control. So, we develop SPMD (Synchronized Phasor Measurement Device) for synchronized phasor measurement of voltage and current. In this paper, we present the design and implementation of SPMD for real-time phasor measurement and the test results of developed SPMD on 380 V 3 phase distribution line in laboratory with resistor load and RTDS (Real Time Digital Simulator).

Observability Analysis for Phasor Measurement Unit Placement (PMU 설치에 따른 가관측성 해석)

  • Kang, Suk-Joo;Cho, Ki-Seon;Kim, Hoi-Cheol;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1049-1053
    • /
    • 1999
  • It is important to measuring and monitoring about state vectors of power system for precise operation control. All state vectors cannot be measured because it is economically disadvantageous, so that some state vectors are determined using state estimator. Determination of observability is a important precondition of power system state estimation because state estimation can be performed when given power system is observable. Recently as time-synchronization technique progress, using the PMU(Phasor Measurement Unit), state vector can be measured directly so that voltage phasor and current phasor measurements can be used for power system estimation. In this paper, observability algorithm is proposed to determinate the observability with real/reactive injection power measurements and real/reactive lineflow power measurements of existing measurement system and with phasor measurements of PMU. The jacobian matrix is newly composed for state estimation with measurements of added PMU, and state estimation is performed with least square estimatior. Comparison between state estimation result of existing measurement system and that of measurement system added PMU is presented.

  • PDF

Implementation of Synchronized Phasor Measurement Unit Using GPS (GPS를 이용한 동기페이저측정장치의 EMTP모델 구현)

  • Cho, Ki-Seon;Heo, Mun-Jun;Choi, Myung-Seok;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1262-1266
    • /
    • 1999
  • More precise operation and control is required to ensure the stability and security of modern large power systems that is a complicated and widely dispersed structure. To ensure the precise operation and control of modern power system, most of all, precise monitoring and measurement of the various state values of power system is required. This paper discusses phasor measurement unit using synchronization signals from the GPS satellite system- Synchronized Phasor Measurement Unit. Considering the power system operation state, the transmitting data format over modems is defined. To provide all available information, PMU process the measurements to generate three phase symmetrical component. This paper proposes the transmitted data format and implements the PMU model using EMTP/Models. The validity of proposed model is confirmed through several contingency on the simple power system.

  • PDF

Calibration Methods for Measurement Uncertainty of Power Assembly Tools (동력식 조립공구의 측정불확도 산출방법 개발)

  • Oh, Se-heon;Kang, Ki-young;Hong, Min-sung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.496-501
    • /
    • 2015
  • In this study, calibration procedure of power assembly tools is suggested and methods are developed for calculating measurement uncertainty. Fist of all, the calibration of joint simulator bench (JSB) was carried out for maintaining traceability and the uncertainty components of JSB were analyzed. The influences of tool speed, tolerance, temperature and length of the adapter were examined by the torque measurement values through experiments. From this research, credibility for calibration results could be enhanced. This experimental results, being used as an effective tool for calibration of power assembly tools, will provide and improve the accuracy of the use of the power assembly tools.

DESIGN OF A VIBRATION AND STRESS MEASUREMENT SYSTEM FOR AN ADVANCED POWER REACTOR 1400 REACTOR VESSEL INTERNALS COMPREHENSIVE VIBRATION ASSESSMENT PROGRAM

  • Ko, Do-Young;Kim, Kyu-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.249-256
    • /
    • 2013
  • In accordance with the US Nuclear Regulatory Commission (US NRC), Regulatory Guide 1.20, the reactor vessel internals comprehensive vibration assessment program (RVI CVAP) has been developed for an Advanced Power Reactor 1400 (APR1400). The purpose of the RVI CVAP is to verify the structural integrity of the reactor internals to flow-induced loads prior to commercial operation. The APR1400 RVI CVAP consists of four programs (analysis, measurement, inspection, and assessment). Thoughtful preparation is essential to the measurement program, because data acquisition must be performed only once. The optimized design of a vibration and stress measurement system for the RVI CVAP is essential to verify the integrity of the APR1400 RVI. We successfully designed a vibration and stress measurement system for the APR1400 RVI CVAP based on the design materials, the hydraulic and structural analysis results, and performance tests of transducers in an extreme environment. The measurement system designed in this paper will be utilized for the APR1400 RVI CVAP as part of the first construction project in Korea.

A Proposal of Combat Power Measurement Model of Army Warfare Information System Using Network Power based on Social Network Analysis (SNA 기반 네트워크 파워를 이용한 지상전장정보체계 전투력 효과측정 모델제안)

  • Jung, Chi-Young;Lee, Jae-Yeong
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.36 no.4
    • /
    • pp.1-16
    • /
    • 2011
  • It is important not only to introduce the C4I(Command and Control, Communication, Computer, Intelligence) system for realizing the NCW(Network Centric Warfare) but also to evaluate the synergistic effect by the C4I system. However, the study effort for evaluating the system's synergistic effect is insufficient compared with introducing the system. Therefore, in this paper, we proposed a model that measures the synergistic effect of combat power by the warfare information system. To measure the synergistic effect of warfare information system, the network power must be considered, so we also proposed a new methodology for measurement of network power based on SNA(Social Network Analysis), not Metcalfe's law. A model we proposed is a model that measures the raised combat power by the network effectiveness. The methodology and model we proposed in this paper will be used usefully to analyze the practical effect of constructing future warfare information system.

Design and Implementation of Intelligent Aircraft Power Measurement System Based on Embedded (지능형 항공기 전력 계측 임베디드 시스템에 설계 및 구현)

  • Choi, Won-Huyck;Jie, Min-Seok
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.664-671
    • /
    • 2013
  • In this paper, in an aircraft power can be measured by wireless AEMS (aircraft electric power measurement monitoring system) system is proposed. AEMS has been design based on current commercialized power measuring systems analysis with improvement and connects it with most talked about item, smart phone and monitoring system. And also adopting real time power measuring system, constitute more practical power measuring system by controlling electricity usage in real time.