Leak Evaluation for Power Plant Valve Using Multi-Measuring Method

  • Lee, Sang-Guk;Park, Jong-Hyuck;Kim, Young-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.469-476
    • /
    • 2008
  • Condition based maintenance(CBM) for the preventive diagnosis of important equipments related to safety or accident in power plant is essential by using the suitable methods based on actual power plant conditions. To improve the reliability and accuracy of the measured value at the minute leak situation, and also to monitor continuously internal leak condition of power plant valve, the development of a diagnosis and monitoring technique using multi-measuring method should be performed urgently. This study was conducted to estimate the feasibility of multi-measuring method using three different methods such as acoustic emission(AE) method, thermal image measurement and temperature difference$({\Delta}T)$ measurement that are applicable to internal leak diagnosis for the power plant valve. From the experimental results, it was suggested that the multi-measuring method could be an effective way to precisely diagnose and evaluate internal leak situation of valve.

Development of Power Measurement System Using Computer (컴퓨터를 이용한 전력 계측기 시스템 개발)

  • 김태성;이우기;오수홍;오무송;최장주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.301-305
    • /
    • 1998
  • The Power measurement that can measure a single quantity does not smooth to install a system, and are not convenient to use. These measuring values are vary difficult for mutual operation and analyzing, and that have too many problems to compile measured databases. If each single measured values are mutual assist, correction and reform, the system will be able to be improved by minimizing differences between measure quantities and as making many different measurement system (Voltage, Current, Power and Resistor) is installed in one system. This study is useful to develope the power measurement system that is easier to analyze and management by database all of the parameter values because the power measurement system is able to be interbased with PC as requirement of industralization and information age.

  • PDF

A Study on the Errors at the Measurement of Sound Power (음향파워 측정 시 오차에 대한 고찰)

  • Na, Hae-Joong;Lim, Byoung-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.917-924
    • /
    • 2012
  • Noise power of large machineries, such as textile looms, winders, and twisting machines, is often measured in a reverberant space because they cannot be installed and operated in an anechoic chamber due to their size, weight, and operating conditions. Factors affecting the measurement error of an in-situ noise power measurement include the nonuniform reverberation time and the direction of sound intensity vector which is usually regarded as normal to the measurement surface. In this study errors due to these factors are estimated with the aid of numerical simulation based on the ray-tracing technique. The averaging of reverberation times measured at several points on the measurement surface is suggested to reduce the errors from nonuniform absorption. Also the direction cosine of each surface element is taken into account, which as a whole is represented as a solid angle of the measurement surface.

The study on the EIRP measurement methods considering Antenna Gain (안테나 이득을 고려한 EIRP 측정 방법에 관한 연구)

  • Kim, Dong-Ho;Choi, Dong-Geun;Shin, Chan-Soo;Sin, Ho-Seop;Kim, Nam
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.555-559
    • /
    • 2003
  • Recently, in accordance with the commercialization of novel radio frequency utilization technologies, the radiated power must be rigorously limited for the purpose of protection of wireless facilities against frequency jamming or interference and for maintaining the quality of communication service. At present, the output power is measured from the conducted power for the domestic measurement criterion but is not a real radiated power and inaccurate. So, it is peformed to survey the more precisely accurate measurement scheme and analyze its criterion and methodology in comparison with foreign one. As a result of surveying and analyzing, it is concluded that the U.S. and E.U. is actually using the measurement method in consideration of terms of the Equivalent Isotropic Radiated Power(EIRP) and Effective Radiated power(ERP). In case of the frequency below 1 GHz, the half wave-length dipole antenna is used to measure the ERP and above 1 GHz the horn antenna as a reference antenna is used to measure the EIRP. Therefore, for the domestic purpose it is also necessary to take EIRP and ERP into consideration as a measurement criterion in order to make an accurate measurement and regulation.

  • PDF

Fabrication and Evaluation of Digital Signal Processor for Multi-Lane Energy Measurement System (개별 전로 전력 계측을 위한 디지털 신호처리 프로세서 기반 전력 관제 시스템의 제작 및 평가)

  • Kim, Geun-Jun;Kang, Bongsoon
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.619-623
    • /
    • 2018
  • Due to the development of society, the demand for electric power has increased and the quality control of electric power has become an important issue. In order to efficiently perform such power management, we propose a DSP based power measurement system for multi-wire power measurement. Since the conventional power measurement system can measure only the power of one line, a power quality measurement device is required for each line in order to measure the power quality of the individual line. Respectively. The system proposed in this paper proposes a system capable of real-time measurement of power quality at up to 12 points using digital signal processing algorithm, and the prototype based on this system was evaluated through the official test report of Korea Electrotechnology Research Institute. As a result of the performance test, it was evaluated that the error range is excellent at ${\pm}0.3%$.

Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement (고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

Transmit-Beam Pattern Measurement of the Active Phased-Array Antenna Using Near-Field Measurement Facility (근접 전계 시험 시설을 이용한 능동 위상 배열 안테나 송신 빔 패턴 측정)

  • Chae, Hee-Duck;Kim, Han-Saeng;Lee, Dong-Kook;Jeong, Myung-Deuk;Park, Jong-Kuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1155-1164
    • /
    • 2011
  • In this paper, we proposed the transmit beam measurement method of active phased array antenna, which is installed in Korea's first developed naval medium range radar, using near-field measurement facility. The pulse-mode high power characteristics of active phased array antenna's trasmit-beam make it difficult to measure with general near-field measurement facilities where low power continuous RF signals are used. Thus, in this paper, the measurement method of active phased array antenna's transmit beam in conjunction with the near-field measurement facility, which is suitable for the high-power transmit beam measurement, and PNA-X network analyzer(Agilent Technologies), which can support pulse-mode measurement, was proposed and measured by near-field measurement techniques. And the EIRP(Effective Isotropic Radiated Power), the transmit characteristic of active phased array antenna, was measured by the near field measurement techniques and compared to numerical estimation which was nearly equal with small difference of 0.1 dB.

A Study on Maximum Power Measurement Method for NOVC-type Hybrid Electric Vehicle (NOVC형식 하이브리드 자동차의 최고 출력측정방법 연구)

  • Kim, Joowon;Yong, Geejoong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.10 no.2
    • /
    • pp.36-42
    • /
    • 2018
  • UNECE/WP29/GRPE/EVE has recently defined that the power of a hybrid electric vehicle is the system power. Although a method for measuring the maximum power of a hybrid electric vehicle is presented by KATRI, it does not consider charging and discharging characteristics of traction batteries. This study provides a maximum power measurement method which reflects the charging and discharging characteristics of traction batteries in NOVC-HEVs (Not Off Vehicle Charging-Hybrid Electric Vehicles). Both methods are compared with regard to the output measurement results.

Real-Time Monitoring and Analysis of Power Systems with Synchronized Phasor Measurements

  • Kim, Hong-Rae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.101-108
    • /
    • 2007
  • State estimators are used to monitor the operating states of power systems in modern EMS. It iteratively calculates the voltage profile of the currently operating power system with voltage, current, and power measurements gathered from the entire system. All the measurements are usually assumed to be obtained simultaneously. It is practically impossible, however, to maintain the synchronism of the measurement data. Recently, phasor measurements synchronized via satellite are used for the operation of these power systems. This paper describes the modified state estimator used to support the processing of synchronized phasor measurements. Synchronized phasor measurements are found to provide synchronism of measurement data and improve the accuracy/redundancy of the measurement data for state estimation. The details of the developed state estimation program and some numerical results of operation are presented.

Development of 3-D. Displacement Measurement System for Critical Pipe of Fossil Power Plant (화력발전소 주배관 3차원 변위측정시스템 개발)

  • Song, G.W.;Hyun, J.S.;Ha, J.S.;Cho, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1198-1205
    • /
    • 2003
  • Most domestic fossil power plant have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe system have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plant, 3-dimensional displacement measurement system were developed for the on-line monitoring system. 3-D Measurement system was developed with using the LVDT type sensor and rotary encoder type sensor, this system was installed and operated on the real power plant successfully. In the future time, network system of on-line diagnosis for critical pipe will be designed.