• 제목/요약/키워드: Power Line Interference

검색결과 201건 처리시간 0.028초

송전선로의 효과적인 건설 연구 (A Study of an effective construction of Transmission Line)

  • 강기홍;이석규;윤영순;이종수;오창효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.244-246
    • /
    • 2003
  • The construction conditions of transmission line in Korea are very hard. Actually, the construction project is processed inefficiently with constant civil appeal and interference by local residents of a region and environment organization, not to speak of landlord, because it is regarded as antipathy facility and passes through a lot of regions. Especially, it is concluded that effective practice of a construction project is serious in the future because transmission power voltage was upgraded to 765kV according to a sharp increase of electric power demand. Therefore, with the background of the experience of the past, this paper is aimed to study and establish a reasonable improvement plan which enables to eliminate wasteful factors for effective construction work of transmission line.

  • PDF

High-Order Stable Notch Filter 기법을 적용한 전력선 통신 시스템 구현 (Implementation of Power Line Communication System Appling High-Order Stable Notch filter Scheme)

  • 김경석;남윤호;김주석
    • 한국통신학회논문지
    • /
    • 제36권1C호
    • /
    • pp.28-36
    • /
    • 2011
  • 최근 인터넷이 주정보원으로 작용하고 인터넷의 보급이 확산되는 정보화시대에 인터넷망이 닿지 않는 지역의 Last Mile Solution에 적합한 대안으로서 전력선 통신에 관한 연구가 진행되고 있다. 현재 200Mbps PLC 장비가 상용화 되는 등 전력선 통신기술의 발달로 통신 인프라가 구축되지 않은 나라에서는 접근만 뿐만 아니라 백본망까지 구축하려는 연구가 진행 중이다. 하지만, 전력선 통신은 전력을 전송하도록 설계되었기 때문에 높은 고주파 신호를 보내게 되면 부근의 무선통신 서비스에 영향을 주게 된다. 이러한 문제점을 해결하기 위해 본 논문에서는 High-Order Stable Notch Filter를 제안하였다. High-Order Stable Notch Filter는 기존의 필터들이 2차로 구현되었다는 점에 착안하여 4차, 6차, 8차, 10차 등 고차로 구현하였다. 또한, 제안한 High-Order Stable Notch Filter를 적용하여 Notch Filter Emulator를 구현하였다.

전력선 통신과 무선 센서 네트워크 기술을 이용한 연동 통합제어 시스템에 관한 연구 (A Study on Linkage Integration Control System Using Power Line Communication(PLC) and Wireless Sensor Network(WSN))

  • 지윤일;임강일;박경섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.733-736
    • /
    • 2009
  • 전력선 통신은 별도의 통신선로가 필요 없어 저렴한 설치비용과 설치가 용이하고 접근이 간편해 다양한 응용시장 하부 네트워크가 가능하나 제한된 전송 데이터와 통신 장애 요소인 높은 부하 간섭과 잡음 문제가 있으며 무선 센서 네트워크는 기반 시설이 불필요하고 센서 노드들 간의 자체적 네트워크 구축이 가능하여 짧은 시간에 구현이 가능하나 QoS의 향상을 위한 능동적 센싱과 불필요한 정보전송으로 인한 전력소모의 증가로 인해 센서 노드의 수명 단축 문제로 저전력 설계와 개선된 프로토콜의 필요성이 언급되고 연구되고 있다. 본 연구에서는 전력선 통신과 무선 센서 네트워크의 문제를 상호 보완하고 장점은 더하여 연동 통합제어 시스템을 구축함으로써 두 기술의 시너지 효과를 이용해 보다 제약이 없고 원활한 네트워크 환경구축을 위해 개선된 제어 네트워크를 구조적으로 접근해보려 한다. 하니웰 사의 하이브리드 센서 네트워크를 비교 분석하고 네트워크 티밍(Teaming)을 제안하며 제안된 전력선 통신과 무선 센서 네트워크의 연동 통합제어 시스템(Linkage Intergration Control System)의 성능 향상의 정도를 시물레이션을 통해 새롭게 제안한 방식의 네트워크 및 개선안이 기존의 네트워크보다 서비스 지연이 줄어들고 성능 향상이 있었음을 확인하려 한다.

  • PDF

근거리의 자외선 비가시거리 통신에 관한 연구 (Study on Short-range Non-line-of-sight Ultraviolet Communication)

  • 박동국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.179-184
    • /
    • 2012
  • 기존의 무선 RF 통신은 근거리에서 전력손실이 상대적으로 크고, 전파간섭 및 방해, 재밍 등에 민감하다. 이러한 단점을 보완하는 대안으로 자외선을 이용한 통신 방식에 대한 연구가 최근 관심을 받고 있다. 본 논문에서 자외선을 이용한 비가시거리 통신의 data rate 특성에 대해 시뮬레이션한 결과를 제시하였다. On-off keying 방식을 사용하는 비가시거리 자외선 통신에서 data rate는 송신 빔의 방향, 수신빔의 빔 폭, 송신 전력에 의해 큰 영향을 받는다는 것을 확인하였다.

지중송전케이블의 도체연가방식 채용시 효용성 평가 (Operation Effectiveness Evaluation According to Conductor Transposition Adoption in Underground Power Cable Systems)

  • 김준;이종범
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.636-643
    • /
    • 2014
  • Length of most underground power cable in nation is not so long. Therefore it is operated without conductor transposition due to low unbalanced ratio. However, if cable length is long, line constant of each cable will be different. Different line constant can induce unbalanced voltage and current of sheath. Also it can induce several induced interference. This paper describes the operation effectiveness through steady and transient analysis on transposition and untransposition of cable conductor. Especially sheath current and induced voltage are analyzed and compared in case of transposition and untransposition. EMTP is used for modeling and analysis.

Analysis and Design of a DC-Side Symmetrical Class-D ZCS Rectifier for the PFC of Lighting Applications

  • Ekkaravarodome, Chainarin;Thounthong, Phatiphat;Jirasereeamornkul, Kamon;Higuchi, Kohji
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.621-633
    • /
    • 2015
  • This paper proposes the analysis and design of a DC-side symmetrical zero-current-switching (ZCS) Class-D current-source driven resonant rectifier to improve the low power-factor and high line current harmonic distortion of lighting applications. An analysis of the junction capacitance effect of Class-D ZCS rectifier diodes, which has a significant impact on line current harmonic distortion, is discussed in this paper. The design procedure is based on the principle of the symmetrical Class-D ZCS rectifier, which ensures more accurate results and provides a more systematic and feasible analysis methodology. Improvement in the power quality is achieved by using the output characteristics of the DC-side Class-D ZCS rectifier, which is inserted between the front-end bridge-rectifier and the bulk-filter capacitor. By using this symmetrical topology, the conduction angle of the bridge-rectifier diode current is increased and the low line harmonic distortion and power-factor near unity were naturally achieved. The peak and ripple values of the line current are also reduced, which allows for a reduced filter-inductor volume of the electromagnetic interference (EMI) filter. In addition, low-cost standard-recovery diodes can be employed as a bridge-rectifier. The validity of the theoretical analysis is confirmed by simulation and experimental results.

대형 송전선로에 의한 TV 전파장해 고찰 (Ghost and Blocking of TV signal by UHV Transmission Lines)

  • 신구용;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1776-1778
    • /
    • 1998
  • KEPCO has been constructing the 765 kV double circuit transmission line since 1997. It is worried that the 765 kV transmission lines make TV interference(Ghost and Blocking) due to high tower and multi sub-conductors. This paper presents the mechanism, the measuring method and the results of TV ghost and blocking measurement using a new TV ghost measurement system in a vehicle which was developed by KEPRI.

  • PDF

전력선 통신이 해상 통신에 주는 전파 방사 영향 연구 (A Study on Impact of emissions from power line communication interfering with marine radio services)

  • 장동원
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.115-118
    • /
    • 2003
  • 본 고에서는 전력선 통신이 해상 통신 서비스에 주는 간섭에 대해서 기술하였다. 전력선 통신 뿐 만 아니라 통신선을 이용하는 ADSL이나 VDSL은 고속의 데이터 전송을 위해 광대역을 사용하는데 이때 발생되는 전파 방사가 해상 통신 둥 기존 무선 서비스에 간섭을 주게 된다. 본 고에서는 30MHz이하의 대역에서 사용되고 있는 해상 통신 서비스가 전력선 통신에 의해서 간섭을 받게 될 수 있는 가능성을 분석하고 이러한 간섭을 피하기 위한 보호 대책에 대해서 기술하였다.

  • PDF

765kV 송전선로용 특수 다중도체 방식의 코로나 잡음특성 및 전계분포 해석 (Analysis on Electric Field Distributions and Corona Characteristics of Special Conductor Bundles for 765kV Transmission Line)

  • 민석원;김용준;신구용;이동일;주문노;양광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권12호
    • /
    • pp.556-560
    • /
    • 2001
  • To solve aeolian noise, we have tried several special conductor bundles equipped with spiral rod and one kind of low aeolian noise conductor with a special shape. Charge simulation method was applied to analyze electric field distributions of them in transmission line and corona cage for investigating the corona characteristics. This paper describes the electric field distributions and the performances of audible noise and radio interference from the special bundles in 765 kV transmission line by using corona characteristics obtained from corona cage simulation.

  • PDF

고차 고조파 전류의 보상을 위한 단상 능동전력필터 (Single-Phase Active Power Filter for Higher-order Harmonic Current Compensation)

  • 성기석;우명호;송중호;최익;임묘택
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권7호
    • /
    • pp.500-508
    • /
    • 2000
  • Basic design for single-phase active power filter, which aims at railway application provided with PWM-controlled converters, is comprehensively studied and its performance is presented in this paper. Active power filters are used to compensate railway signaling and public telecommunication interference due to the high-order harmonic currents generated in railway traction locomotives. A type of hybrid digital filter which is composed of low pass filter and high pass filter is proposed so that the desired harmonic reference current with accurate magnitude and phase shift can be extracted from catenary line current. A design criteria to determine input inductor L and output capacitor C is also described, considering voltage, current, PWM pattern, and switching frequency of the main converters. Finally, computer simulation and DSP-based experiments resulted from laboratory test are presented.

  • PDF