• Title/Summary/Keyword: Power Flow problem

Search Result 422, Processing Time 0.06 seconds

Transient Power Flow Analysis of Beam and Plate (과도 입력파워에 대한 보와 평판의 파워흐름해석)

  • Hwang, Dae-Woong;Seo, Seong-Hoon;Kwon, Hyun-Wung;Hong, Suk-Yoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.624-631
    • /
    • 2007
  • PFA (power flow analysis) has been recognized as a useful method in vibration analysis of medium-to-high frequency ranges. Until now, PFA method has been developed for steady-state vibration problems. In this paper, PFA method has been expanded to transient problem. New energy governing equations are derived considering time dependent terms in beam and plate. Analytic solutions of those equations are found in simple beam and plate, and are verified by comparing with modal solutions.

Economic Dispatch based on Primal Interior Point Method (Primal Interior Point 법에 의한 경제급전)

  • Jung, Leen-Hark;Cho, Yang-Haeng;Park, Kyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.366-368
    • /
    • 2002
  • This paper presents a technique that can obtain an optimal solution for the Security-Constrained Economic Dispatch (SCED) problems using the Interior Point Method (IPM) while taking into account of the power flow constraints. The SCED equations are formulated by using only the real power flow equations from the optimal power flow. Then an algorithm is presented that can linearize the SCED equations based on the relationships among generation real power outputs, loads, and transmission losses to obtain the optimal solutions by applying the linear programming (LP) technique. Finally, the application of the Primal Interior Point Method (PIPM) for solving the optimization problem based on the proposed linearized objective function is presented. The results are compared with the Simplex Method and the Promising results ard obtained.

  • PDF

A Comparison of Distributed Optimal Power Flow Algorithm (최적조류계산 분산처리 기법의 비교)

  • Kim, Ho-Woong;Park, Marn-Guen;Kim, Bal-Ho;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1046-1048
    • /
    • 1999
  • This Paper compares two mathematical decomposition coordination methods to implementing the distributed optimal Power flow(OPF) using the regional decomposition: the Auxiliary Problem Principle(APP) and the Alternating Direction Method(ADM), a variant of the conventional Augmented Lagrangian approach. A case study was performed with IEEE 50-bus system.

  • PDF

A New Approach to Optimal Power Flow using Conjugate Gradient Method (공액 경사법을 사용한 최적조류계산에 대한 새로운 접근법)

  • Jo, Han-Hyung;Kim, Weon-Kyum;Kim, Kern-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.139-142
    • /
    • 1990
  • This paper presents a new approach to optimal power flow (OPF) problem using conjugate gradient method, using this method. We can obtain initial feasible solution and lagrangian multiplier without calculation of matrix inversion.Test experiment shows a desiriable result and a stable convergence characteristic.

  • PDF

A Study on the Effective Coordination Scheme of Recloser for the Conventional Distribution System Interconnected Dispersed Generation (배전계통에 분산전원 연계시 기존 배전 계통측의 효과적인 리클로저 보호협조 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Moon, Jong-Fil;Yun, Sang-Yun;Choi, Joon-Ho;Bae, Joo-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.533-535
    • /
    • 2002
  • In Korea, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern of dispersed generation system(DGS) is growing. The power distribution system is generally operated with radial type. The protection system is composed of one directive source. But power distribution system inserted DGS changes it to two directive source system. Therefore, the insertion of DGS has the problem of protection coordination. In this paper, we argue fault current affected by interconnected DGS. We analyze fault current flow affected by DGS placement. Then, we find protective coordination problem. Consequently, we study advance point for protection scheme of power system interconnected DGS.

  • PDF

OPERATION MODES ANALYSIS FOR A DVR IN DISTRIBUTION GRIDS

  • Kim, Hyo-Sung;Kim, Pederson John
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.480-483
    • /
    • 2001
  • Recent power quality measurement projects report that voltage sags are the most frequent disturbances in the sites [1]-[4]. DVRs were emerged as the best effective and economic solution for this problem [11]. This paper analyzed the power flow of a DVR in distribution grids. This paper showed various operation modes and boundaries such as inductive operation, capacitive operation, and minimal power operation beside the in-phase compensation.

  • PDF

Power System Congestion Problems using Hybrid Control of PST and Real Power Generation (위상변환기와 발전출력 하이브리드 제어를 이용한 계통 혼잡처리 방안)

  • Kim, Kyu-Ho;Song, Kyung-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.223-225
    • /
    • 2005
  • This paper presents a scheme to solve the congestion problem using hybrid control with phase-shifting transformer(PST) and power generation in power systems. A good design of PST and power generation control can improve total transfer capability(TTC) in interconnected systems. This paper deals with an application of optimization technique for TTC calculation. The optimization method is used to maximize power flow of tic line subject to security constraints such as voltage magnitude and real power flow. The proposed method is applied to 10 machines 39 buses model systems to show its effectiveness.

  • PDF

Analysis, Design, and Implementation of a High-Performance Rectifier

  • Wang, Chien-Ming;Tao, Chin-Wang;Lai, Yu-Hao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.905-914
    • /
    • 2016
  • A high-performance rectifier is introduced in this study. The proposed rectifier combines the conventional pulse width modulation, soft commutation, and instantaneously average line current control techniques to promote circuit performance. The voltage stresses of the main switches in the rectifier are lower than those in conventional rectifier topologies. Moreover, conduction losses of switches in the rectifier are certainly lower than those in conventional rectifier topologies because the power current flow path when the main switches are turned on includes two main power semiconductors and the power current flow path when the main switches are turned off includes one main power semiconductor. The rectifier also adopts a ZCS-PWM auxiliary circuit to derive the ZCS function for power semiconductors. Thus, the problem of switching losses and EMI can be improved. In the control strategy, the controller uses the average current control mode to achieve fixed-frequency current control with stability and low distortion. A prototype has been implemented in the laboratory to verify circuit theory.

A Study on the Quantatitive Voltage Stability Index Considering Load Voltage Characteristics (부하의 전압특성을 고려한 정량적 전압안정성 지표에 관한 연구)

  • Jeong, Joon-Mo;Lee, Bong-Yong;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.3-5
    • /
    • 1994
  • It is shown that the power flow considering the voltage characteristic of the composite load has some difference comparing with conventional load flow in this paper. When the load flow is used in a study of the static voltage stability, it is necessary to consider the voltage characteristic of load, since the composite load of a typical power system bas constant power, constant current, and constant impedance characteristic. The load is modeled to a polynomial form in here, and used in solving the load flow problem. In this way, the effect which the voltage characteristic of the load has on several voltage collapse proximity indicator based on sensitivities is compared with the conventional load flow, or with another load model having a different voltage characteristic. In this paper, the voltage collapse proximity indicator using the sensitivity of real power for transmission loss is also proposed, and compared with other indicators.

  • PDF

Research of Flow Electrification Phenomena of the used Environment-Friendly Vegetable Insulating Oils (친환경 식물성절연유의 유동대전현상 연구)

  • Choi, Sun-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.580-584
    • /
    • 2012
  • The insulating oils perform a cooling and insulation action in electric power transformer. The mineral oil has immanent fire dangerousness and environmental contamination problem. Vegetable insulating oil has higher ignition point, flash point and more excellent biodegradability than conventional mineral oil. In a real oil-filled transformers, some of the power is dissipated in the form of heat. And transformer require the heat to be removed from the winding and insulator by forced convection of the insulating oil. The flow electrification occurs when insulating oil was forced to be circulated. In this paper, influence of temperature, velocity of flow, and insulating pipe and diameter on streaming electrification of vegetable insulating oil was investigated using forced circulation apparatus. Temperature effects were most significant, and it showed a peak in the temperature $30^{\circ}C$ to $35^{\circ}C$ at insulating and copper pipe. The change of flow electrification according to area variety could be checked by change of diameter.