• Title/Summary/Keyword: Power Domain

Search Result 1,343, Processing Time 0.025 seconds

Time-Domain Analysis of Wireless Power Transfer System Behavior Based on Coupled-Mode Theory

  • Shim, Hyunjin;Nam, Sangwook;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.219-224
    • /
    • 2016
  • In this paper, coupled-mode theory (CMT) is used to obtain a transient solution analytically for a wireless power transfer system (WPTS) when unit energy is applied to one of two resonators. The solutions are compared with those obtained using equivalent circuit-based analysis. The time-domain CMT is accurate only when resonant coils are weakly coupled and have large quality factors, and the reason for this inaccuracy is outlined. Even though the time-domain CMT solution does not describe the WPTS behavior precisely, it is accurate enough to allow for an understanding of the mechanism of energy exchange between two resonators qualitatively. Based on the time-domain CMT solution, the critical coupling coefficient is derived and a criterion is suggested for distinguishing inductive coupling and magnetic resonance coupling of the WPTS.

An Adaptive Narrowband Interference Excision Filter with Low Signal Loss for GPS Receivers

  • Shin, Mi-Young;Park, Chan-Sik;Lee, Ho-Keun;Lee, Dae-Yearl;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1234-1238
    • /
    • 2005
  • As the low power GPS signal is susceptible to interference, interference can seriously degrade the performance of GPS receiver. This paper designs a ANIEF(Adaptive Narrowband Interference Excision in Frequency domain) filter that removes narrow band interferences with low signal loss. This filter uses the pre-correlation technique and attempts to filter out the interference in the frequency domain. The interference excision performance of the designed filter is evaluated for various interferences using the ANIEF filter inserted GPS software receiver and the interference generator. Interferences considered in this paper are single-tone CWI(Continuous Wave Interference), multi-tones CWI, pulsed CWI, and swept CWI. The narrowband interference excision filter in frequency domain is very effective against various interferences and the strong interference with a simple structure. However, the signal power loss is unavoidable while transforming. In this paper, the hamming window and overlap technique are adopted to reduce the signal power loss. Finally, the interference excision performance and the reduced signal power loss of the ANIEF filter are shown.

  • PDF

Digital State Feedback Current Control using the Pole Placement Technique

  • Bae, Hyun-Su;Yang, Jeong-Hwan;Lee, Jae-Ho;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.213-221
    • /
    • 2007
  • A digital state feedback control method for the current mode control of DC-DC converters is proposed in this paper. This approach can precisely achieve interleaved current sharing among the converter modules. As the controller design and system analysis are performed in the time domain, the proposed method can easily satisfy the required converter specification by using the pole placement technique. The digital state feedback controller in the continuous and discrete time domain is derived for the robust tracking control. For the verification of the proposed control scheme, a parallel module bi-directional converter in a prototype 42V/14V hybrid automotive power system, which is a design example in the continuous time domain, and a parallel module buck converter, which is a design example in the discrete time domain, are implemented using a TMS320F2812 digital signal processor (DSP).

Definition of Powers and Power Quality Factors at a Point of Common Coupling in Single-Phase Systems and Three-Phase Systems

  • Kim, Hyosung;Frede Blaabjerg;Jensen, Birgitte-Bak
    • Journal of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.32-45
    • /
    • 2002
  • This paper proposes an unified definition of powers for various circuit conditions such as balanced/unbalanced, sinusoidal/non-sinusoidal, and linear/nonlinear, fur single-phase systems and three-phase systems. Conventional reactive power is more classified into an interactive power and an alternating power. These powers are defined both in the time domain and the frequency domain consistently, and agree well with the conservation law. Several important power quality factors are defined to measure and evaluate the power quality fur the various circuits in the single-phase and three-phase systems. Simulation results show the power quality factors can evaluate and classify the various circuit conditions clearly.

Parameter Identifieation of Nonlinear Structure (비선형 구조물의 매개변수 규명)

  • 김우영;황원걸;기창두
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.363-368
    • /
    • 1993
  • Hilbert Transform has been used for detection of nonlinearity in modal analysis. HTD(Hilbert Transform Describers) are used to quantify and identify nonlinearity. Mottershead and Stanway method for identification of N-th power velocity nonlinear damping are extended to P-th power displacement stiffness, N-th power velocity damping and dry friction. Time domain and frequency domain data are used and HTD and Mottershead methods are combined for identification of nonlinear parameters in this paper. Computer simulations and experimental results are shown to verify nonlinear structure identification methods.

  • PDF

Evaluation of a Self-Adaptive Voltage Control Scheme for Low-Power FPGAs

  • Ishihara, Shota;Xia, Zhengfan;Hariyama, Masanori;Kameyama, Michitaka
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.3
    • /
    • pp.165-175
    • /
    • 2010
  • This paper presents a fine-grain supply-voltage-control scheme for low-power FPGAs. The proposed supply-voltage-control scheme detects the critical path in real time with small overheads by exploiting features of asynchronous architectures. In an FPGA based on the proposed supply-voltage-control scheme, logic blocks on the sub-critical path are autonomously switched to a lower supply voltage to reduce the power consumption without system performance degradation. Moreover, in order to reduce the overheads of level shifters used at the power domain interface, a look-up-table without level shifters is employed. Because of the small overheads of the proposed supply-voltage-control scheme and the power domain interface, the granularity size of the power domain in the proposed FPGA is as fine as a single four-input logic block. The proposed FPGA is fabricated using the e-Shuttle 65 nm CMOS process. Correct operation of the proposed FPGA on the test chip is confirmed.

Frequency Characteristics of the Synchronous-Frame Based D-Q Methods for Active Power Filters

  • Wang, Xiaoyu;Liu, Jinjun;Hu, Jinku;Meng, Yuji;Yuan, Chang
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.91-100
    • /
    • 2008
  • The d-q harmonic detecting algorithms are dominant methods to generate current references for active power filters (APF). They are often implemented in the synchronous frame and time domain. This paper researches the frequency characteristics of d-q synchronous transformations, which are closely related to the analysis and design issues of control system. Intuitively, the synchronous transformation is explained with amplitude modulation (AM) in this paper. Then, the synchronous filter is proven to be a time-invariant and linear system, and its transfer function matrix is derived in the stationary frames. These frequency-domain models imply that the synchronous transformation has an equivalent effect of frequency transformation. It is because of this feature, the d-q method achieves band-pass characteristics with the low pass filters in the synchronous frame at run time. To simplify these analytical models, an instantaneous positive-negative sequence frame is proposed as expansion of traditional symmetrical components theory. Furthermore, the synchronous filter is compared with the traditional bind-pass filters based on these frequency-domain analytical models. The d-q harmonic detection methods are also improved to eliminate the inherent coupling effect of synchronous transformation. Typical examples are given to verify previous analysis and comparison. Simulation and experimental results are also provided for verification.

Multi-Impedance Change Localization of the On-Voltage Power Cable Using Wavelet Transform Based Time-Frequency Domain Reflectometry (웨이블릿 변환 기반 시간-주파수 영역 반사파 계측법을 이용한 활선 상태 전력 케이블의 중복 임피던스 변화 지점 추정)

  • Lee, Sin Ho;Choi, Yoon Ho;Park, Jin Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.667-672
    • /
    • 2013
  • In this paper, we propose a multi-impedance changes localization method of on-voltage underground power cable using the wavelet transform based time-frequency domain reflectometry (WTFDR). To localize the impedance change in on-voltage power cable, the TFDR is the most suitable among reflectometries because the inductive coupler is used to inject the reference signal to the live cable. At this time, the actual on-voltage power cable has multi-impedance changes such as the automatic section switches and the auto load transfer switches. However, when the multi-impedance changes are generated in the close range, the conventional TFDR has the cross term interference problem because of the nonlinear characteristics of the Wigner-Ville distribution. To solve the problem, the wavelet transform (WT) is used because it has the linearity. That is, using WTFDR, the cross term interference is not generated in multi-impedance changes due to the linearity of the WT. To confirm the effectiveness and accuracy of the proposed method, the actual experiments are carried out for the on-voltage underground power cable.

Analysis Method of Signal Integrity for Mobile Display Circuit Modules (모바일 디스플레이 회로 모듈의 시그널 인티그리티 해석 기법)

  • Lee, Yong-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.64-69
    • /
    • 2009
  • This paper addresses the simulation methodology of signal integrity and power integrity for mobile display modules. The proposed technique can be applied to analyse a circuit module which consist of connector, FPCB and driver ICs. The recent demand of serial interconnection technology in the mobile display industry needs delicate impedance control of signal and power traces to prohibit system malfunctioning and to reduce electromagnetic field radiation. Based on the S-parameter and Z-parameter analysis, we analyse the correlation between frequency-domain and time-domain measurements. With multi-port macros, signal integrity can be included in power integrity analysis in time domain.

Definition of Power Quality Factors at The Point of Common Coupling in Single-Phase Systems and Three-Phase Systems

  • Kim Hyosung;Blaabjerg Frede;Bak-Jensen Birgitte
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.489-496
    • /
    • 2001
  • This paper proposes an unified definition of powers for various circuit conditions such as balanced/unbalanced, sinusoidal/non-sinusoidal, and linear/nonlinear, for single-phase systems and three-phase systems. Conventional reactive power is more classified into an interactive power and a scattering power. These powers are defined both in the time domain and the frequency domain consistently, and agree well with the conservation law. Several important power quality factors are defined to measure and evaluate the power quality for the various circuits in the single-phase and three-phase systems. Simulation results show the power quality factors can evaluate and classify the various circuit conditions clearly.

  • PDF