• Title/Summary/Keyword: Power Conditioning System (PCS)

Search Result 195, Processing Time 0.021 seconds

High Frequency Link PCS for Interfacing with Power Utility System (고주파링크 전력계통 연계형 PCS)

  • Chung, Bong-Gun;Yoon, Kwang-Ho;Lee, Kwang-Ho;Kim, Eun-Soo;Cha, In-Su
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.60-68
    • /
    • 2010
  • Recently, Power Conditioning System (PCS) tends to require more compact, higher efficiency and power density with better performance. A novel topology consisted of LLC resonant inverter and Low Frequency (LF) cyclo-converter for connecting to utility line is able to meet these requirements. The technical operating analysis is described and 1kW prototype is tested and verified the performances through connecting the 110Vac 60Hz utility line. Efficient results are described.

High-Efficiency Power Conditioning System for Grid-Connected Photovoltaic Modules

  • Choi, Woo-Young;Choi, Jae-Yeon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.561-567
    • /
    • 2011
  • This paper presents a high-efficiency power conditioning system (PCS) for grid-connected photovoltaic (PV) modules. The proposed PCS consists of a step-up DC-DC converter and a single-phase DC-AC inverter for the grid-connected PV modules. A soft-switching step-up DC-DC converter is proposed to generate a high DC-link voltage from the low PV module voltage with a high-efficiency. A DC-link voltage controller is presented for constant DC-link voltage regulation. A half-bridge inverter is used for the single-phase DC-AC inverter for grid connection. A grid current controller is suggested to supply PV electrical power to the power grid with a unity power factor. Experimental results are obtained from a 180 W grid-connected PV module system using the proposed PCS. The proposed PCS achieves a high power efficiency of 93.0 % with an unity power factor for a 60 Hz / 120 Vrms AC power grid.

Design of 1kW Hybrid CC/CV PCS (정전류·정전압 기능의 1kW급 하이브리드 PCS 설계)

  • Lee, Jae Min
    • Journal of Digital Contents Society
    • /
    • v.14 no.4
    • /
    • pp.529-536
    • /
    • 2013
  • Lack of proper amount of sun lights and wind strength which are major factors of solar power and wind power system may cause poor electric power generation and decrease the lifetime of batteries that are major energy saving units. Because the PCS, which is essential in solar and wind power system, for small power generation system has been rarely developed an efficient and stable PCS for small power generation system is highly required. In this paper, we design a new constant current/constant voltage type hybrid PCS by which stand alone/grid connected operation with commercial power system is available and implement the designed PCS as a protype for performance verification.

The Development & Performance Test of 10[kW] Power Conditioning System for Microgrid (마이크로그리드용 10[kW] PCS 개발 및 성능시험)

  • Lee, Hak-Ju;Chae, Woo-Kyu;Park, Jung-Sung;Kim, Ju-Yong;Kim, Chan-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.55-62
    • /
    • 2011
  • PCS(Power Conditioning System) is the necessary component in Microgrid, composed of multiple distributed generators and energy storage system. In this paper, the functions of PCS are defined and 10[kW] PCS for PV and BESS are developed. To apply PCSs to Microgrid, this paper presents a 3-phase inverter with the decoupling current controller, voltage controller and DPLL control system. PCSs were applied to 120[kW] pilot plant and its performance tests were carried out. Test results of PCS at each operation mode show stable in Microgrid.

Development of Power Conditioning System for High Power Fuel Cell System (대용량 연료전지 발전시스템용 전력변환기 개발)

  • Kang, Ho-Hyun;Lee, Jin-Hee;Baek, Seung-Taek;Jung, Hong-Ju;Chung, Joon-Mo;Suh, In-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.153-156
    • /
    • 2007
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a 250kW Molten Carbonate Fuel Cell (MCFC) generation system. A DSP controller was used to control the dc-dc and dc-ac converter operation for grid connection and power injection to the grid. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of dc-dc converters was proposed and verified. A 250kW prototype was successfully built and tested. Experimental performances are compared to minimum target requirements of the PCS for MCFC.

  • PDF

Development of Battery Simulator for Performance Verification of MW-class PCS (MW급 PCS 성능검증용 배터리 모의장치 개발)

  • Lee, Jong-Hak;In, Dong-Seok;Heo, Nam-Eok;Park, Young-Min;Park, Ki-Won;Kwon, Byung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.160-167
    • /
    • 2016
  • An energy storage system (ESS) is applied to increase the energy efficiency of large plants or buildings that consume much energy, to improve the power quality of power systems, and to stabilize renewable energy source such as photovoltaic or wind turbine. The ESS is composed of a power conditioning system (PCS) and an energy storage. The battery is used as the energy storage. The battery is needed to design and verify a hardware and control system of PCS. Usually, a battery simulator is used instead of a battery, which is costly and hard to manage. In this paper, the development of the battery simulator for performance verification of the MW-class PCS is described. The battery simulator simulates the charging and discharging characteristics of batteries to design and verify the hardware and control system of PCS.

A Study on the Protective Function Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 보호기능 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.341-344
    • /
    • 2009
  • In this paper, protective function evaluation was conducted to determine the performance and safety of a power conditioning system(PCS) for 1kW residential fuel cell system. It is essential to have a power quality, grid-connection and safety of PCS. Even though it is under 500ms by KGS-A410 standard, it is shown a rapid response time of 25ms from input under-voltage test. In terms of output over/under-voltage test, it is shown 29.15 and 79.4ms. Especially using anti-islanding test, it is shown all times under 100ms for combination cases of real and reactive power. We confirmed a rapid response characteristics and safety of PCS. The results of this evaluation are being used to develop a new test protocols of PCS.

  • PDF

Development of Power Conditioning System Control Algorithm for the Parallel Operation of High-Power Fuel Cell System (대용량 연료전지 시스템의 병렬운전을 위한 전력변환기 제어 알고리즘 개발)

  • Lee, Jin-Hee;Baek, Seung-Taek;Choi, Joon-Young;Suh, In-Young;Kim, Do-Hyung;Lim, Hee-Chun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.65-68
    • /
    • 2008
  • This paper proposes the parallel operation control algorithm of a power conditioning system (PCS) for a distributed Fuel Cell power generation system. A proposed control algorithm is made good a drawback of the conventional control algorithm. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. Simulation results are presented to performance of a proposed control algorithm for the PCS.

  • PDF

A Study of Islanding Detection of Grid-connected Three-phase Photovoltaic Power Conditioning System

  • Jung Y.S.;Yu G.J.;Choi J.Y.;Choi J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.761-764
    • /
    • 2003
  • Islanding phenomenon of a grid-connected photovoltaic (PV) power conditioning system (PCS) is said to occur if the PCS continues to power a section of the utility system after that section has been disconnected from the utility source. Since islanding creates hazards for personnel and equipment, PCSs are required to detect and prevent Et. In this paper, several islanding detection methods (IDMs) and reactive power variation method are described. Islanding test results for 9kW PCS are presented for verification.

  • PDF

Performance Evaluation and Development of the Power Conditioning System for 250kW Molten Carbonate Fuel Cell (250kW급 MCFC용 전력변환기 개발 및 성능평가)

  • Lee, Jin-hee;Son, Ui-kwon;Suh, In-young
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.261-262
    • /
    • 2010
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a Molten Carbonate Fuel Cell (MCFC) for high power generation system. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of 250kW PCS was implemented and verified respectively. Experimental performances are compared to minimum target requirements of the PCS for MCFC respectively.

  • PDF