• Title/Summary/Keyword: Power변환

Search Result 3,463, Processing Time 0.034 seconds

Design of DC-DC Converter to Charge and Discharge Lithium Battery Using Isolated Boost Converter and Forward Converter (절연된 부스트 변환기와 포워드 변환기를 이용한 리튬전지 충방전용 직류-직류 변환기의 설계)

  • Kim, Hee-Sun;Chung, Dae-Taek;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.441-450
    • /
    • 2010
  • Lithium battery is widely used as the power source of various electronic devices. The formation process which is the repeated charging and discharging process is essential in the production of lithium battery. In this paper, it is proposed and designed the DC-DC converter that can charge and also discharge the lithium battery in one converter. The proposed converter is designed by considering the charge/discharge characteristics of the lithium battery. The converter is operated as a forward converter in charging process and a electrically isolated boost converter in discharging process. Based on the analyses, the number of transformer turns, inductor, capacitor, and switching devices are designed. Finally, the validity of the design for the proposed converter is verified by both simulations and experiments.

Comparison of Two Parallel Differential Power Processing Configurations (병렬 Differential Power Processing 컨버터의 비교 분석)

  • Lee, Hyunji;Kim, Katherine Ann
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.48-49
    • /
    • 2017
  • 태양광 발전 시스템 구현에 있어 가장 큰 문제점 중 하나는 불균일한 태양빛 조건에서의 전체 시스템 발전량 감소이다. 이를 해결하기 위해 module-integrated converter (MIC), dc optimizer, differential power processing (DPP) 등 다양한 컨버터가 연구되고 있다. 그 중에서도 DPP 컨버터는 낮은 전력변환 손실로 높은 시스템 효율을 얻을 수 있어 최근 많은 주목을 받고 있다. 보통 그리드 연결형 태양광발전 시스템에 적용되는 직렬 DPP의 경우, 이미 많은 연구가 진행되고 있지만, 병렬 DPP의 경우 아직 많은 연구가 필요한 상황이다. 본 논문에서는 front-end 컨버터의 존재 유무에 따른 두 가지 병렬 DPP 컨버터 배열을 비교 분석 하였다. Front-end 컨버터가 적용된 병렬 DPP 컨버터 배열의 경우, dc 전압과 태양전지의 전압 차이를 최소화해 전력 변환 손실을 감소시킬 수 있지만, front-end 컨버터에서 추가적인 전력 변환 손실이 발생한다. Front-end 컨버터가 없는 경우, dc 전압과 태양전지의 전압차이가 커 DPP 컨버터에서 발생하는 전력 변환 손실이 커진다. 따라서 주어진 조건 아래 효율적인 병렬 DPP 컨버터 디자인을 위한 가이드라인을 본 논문에서 제시하고자 한다.

  • PDF

Volatility-nonstationary GARCH(1,1) models featuring threshold-asymmetry and power transformation (분계점 비대칭과 멱변환 특징을 가진 비정상-변동성 모형)

  • Choi, Sun Woo;Hwang, Sun Young;Lee, Sung Duck
    • The Korean Journal of Applied Statistics
    • /
    • v.33 no.6
    • /
    • pp.713-722
    • /
    • 2020
  • Contrasted with the standard symmetric GARCH models, we consider a broad class of threshold-asymmetric models to analyse financial time series exhibiting asymmetric volatility. By further introducing power transformations, we add more flexibilities to the asymmetric class, thereby leading to power transformed and asymmetric volatility models. In particular, the paper is concerned with the nonstationary volatilities in which conditions for integrated volatility and explosive volatility are separately discussed. Dow Jones Industrial Average is analysed for illustration.

Power Conversion System for Electric Power Take-off of Agricultural Electric Vehicle (농업용 전기차량의 전기식 동력인출장치용 전력변환시스템)

  • Kwak, Bongwoo;Kim, Jonghoon
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.994-1002
    • /
    • 2019
  • In this paper, we propose the development of a power conversion system for electric power take-off (e-PTO) of agricultural electric vehicles. Most e-PTOs use commercial power $220V_{AC}$. A bidirectional power conversion system having a two-stage structure consisting of a DC-DC converter and a DC-AC inverter for supplying a high output voltage using a low battery voltage of an agricultural electric vehicle is suitable. we propose a power conversion system consisting of the one-stage dual active bridge (DAB) converter and the two-stage bidirectional full bridge inverter. In addition, we propose a soft start algorithm for reducing the inrush current generated by the link capacitor charging during the initial operation. A 3kW prototype system and its corresponding algorithms have been implemented to verify its effectiveness through experiments.

Development of a 3.3kW Photovoltaic Inverter meeting IP65 standard (밀폐형 구조를 갖는 3.3kW급 태양광용 전력변환기 개발)

  • Jung, Sang-Min;Jang, Su-Jin;Lee, Jeong-Min;Goo, Tae-Hong;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.637-639
    • /
    • 2008
  • 본 논문은 밀폐형 구조를 갖는 3.3kW급 태양광용 전력변환기 개발에 관한 내용을 설명한다. 3.3kW급 전력변환기는 무게, 부피, 효율적인 측면에서 장점을 갖는 무변압기형으로 동작범위가 넓고 실외형(IP65)으로 제작되어 설치 장소에 제약을 받지 않는다. 또한, 주변온도 $-20{\sim}50^{\circ}C$에서 동작이 가능하도록 설계 되었다.

  • PDF

A Study on the Development of 38 GHz Hybrid Power Amplifier Module (38 GHz 하이브리드 전력증폭기 모듈 개발에 관한 연구)

  • 윤양훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.10B
    • /
    • pp.1701-1706
    • /
    • 2000
  • In this work a 38 GHz hybrid 2-stage power amplifier module using GaAs pHEMTs and waveguide to microstrip transitions has been successfully developed. A 10 mil thickness duroid substrate was use for fabrication of the power amplifier and the waveguide to microstrip transitions. The fabricated waveguide to microstrip transition showed about 1 dB insertion loss(back to back) at 32-40 GHz. The measured results of power amplifier module showed 29 dBm output power(P1.5dB), 7,2 dB associated gain and 11.2% power-added efficiency(PAE) at 36.8-38.5 GHz.

  • PDF

Accelerated Deterioration Test Method of High Power Thyristor for HVDC (전력계통용 대용량 사이리스터의 가속열화 시험법)

  • Seo, K.S.;Kim, S.C.;Kim, N.K.;Kim, H.W.;Kim, E.D.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1785-1787
    • /
    • 2003
  • 본 논문에서는 현재 대용량 전력변환 소자인 사이리스터는 해남-제주간의 HVDC변환소에 채용되어 운전중에 있고, BTB 및 SVC등에 채용되고 있으며, 향후 FACTS, 남북 전력계통연계, 동북아 계통연계 등 전력변환용으로 사용될 부품으로 사용범위가 날로 증가하고 있는 2,208개의 사이리스터의 수명 및 신뢰성을 평가하기 위해 고온직류 blocking 가속열화시험조건에 대해서 기술하였다.

  • PDF

Design of a 6bit 250MS/s CMOS A/D Converter using Input Voltage Range Detector (입력전압범위 감지회로를 이용한 6비트 250MS/s CMOS A/D 변환기 설계)

  • Kim, Won;Seon, Jong-Kug;Jung, Hak-Jin;Piao, Li-Min;Yoon, Kwang-Sub
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.5
    • /
    • pp.16-23
    • /
    • 2010
  • This paper presents 6bit 250MS/s flash A/D converter which can be applied to wireless communication system. To solve the problem of large power consumption in flash A/D converter, control algorithm by input signal level is used in comparator stage. Also, input voltage range detector circuit is used in reference resistor array to minimize the dynamic power consumption in the comparator. Compared with the conventional A/D converter, the proposed A/D converter shows 4.3% increase of power consumption in analog and a seventh power consumption in digital, which leads to a half of power consumption in total. The A/D converter is implemented in a $0.18{\mu}m$ CMOS 1-poly 6-metal technology. The measured results show 106mW power dissipation with 1.8V supply voltage. It shows 4.1bit ENOB at sampling frequency 250MHz and 30.27MHz input frequency.

Self Oscillation DC/DC Converter With High Voltage Step-up Ratio (고전압 변환 비의 자려 발진 DC/DC 컨버터)

  • Jung, Yong-Joon;Han, Sang-Kyoo;Hong, Sung-Soo;Jung, Dong-Yeol;Kim, Jin-Wook;Lee, Hyo-Bum;Roh, Chung-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.286-288
    • /
    • 2008
  • 본 논문은 낮은 입력 DC전압에서 높은 음의 DC전압을 출력하는 높은 전환 비의 극성 반전 형 DC/DC 전력 변환 회로에 관한 것으로써, 하나의 스위치, 하나의 인덕터, 그리고 다수개의 캐패시터와 다이오드로 구성된다. 기존의 극성 반전 형 DC/DC 컨버터 회로와 비교하여, 고압 변환 트랜스포머 대신에 인덕터를 사용할 수 있어, 자기 소자의 부피 및 크기는 물론 원가저감이 가능하다. 또한 자려 발진(Self Oscillation) 방식을 사용하여 별도의 제어 IC가 필요 없으므로, 회로구성이 대단히 간단하고, 저가격의 전원 회로를 만들 수 있다. 또한 다이오드들의 전압 스트레스가 감소하여 저가격 고성능의 고압 변환장치 구현이 가능하다. 제안된 회로의 동작원리를 설명하고, 타당성을 Simulation 및 실험을 통하여 검증한다.

  • PDF

Design of Digital Current Mode Control for Power Converters (전력변환회로의 디지털 전류모드제어기 설계)

  • Jung Young-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.162-168
    • /
    • 2005
  • In this paper, a digital current mode control is designed for the power converter applications. The designed digital current mode controller is derived analytically from the continuous time small signal model of the power converters. Due to the small signal model based derivations of the control law, the designed control method can be applicable to boost, buck, and buck-boost converters. It is also proven that the controlled power converter employing the designed digital current mode controller is always stable regardless of an operating conditions. In order to show the usefulness of a designed controller, experiments are carried out using a 16bit DSP micro-processor, TMS320LF2406A.