• Title/Summary/Keyword: Power/ground

Search Result 1,873, Processing Time 0.024 seconds

Analysis of the International Safety Criteria of IEEE Std 80 and IEC 479-1 (배전용 접지전극 안전성 분석을 위한 국제기준 검토)

  • Kang, Moon-Ho;Park, Jae-Duck;Lee, Heung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.214-217
    • /
    • 2005
  • To improve the safety of facilities and human beings when the ground fault occurs, public power utility prescribes the reasonable ground resistances, measures and controls the ground resistance of all the ground electrodes biennially. Concerning the safety of human, there are two safety criteria widely accepted, i.e. the IEEE Std 80-2000 and the IEC 479-1:1994. The IEEE Std 80-2000 is based on a simplified electric shock model usually translated into permissible touch and step voltages. The IEC 479-1:1994 is less specific than IEEE Std 80-2000 for analysis purpose. The IEC 479-1:1994 provides values of permissible body current against electric shock duration. This paper provides a technical study of these two standards to analyze the safety of human beings of ground electrodes developed recently for distribution power system.

  • PDF

Flow analysis of 3-Dimensional Power-Augmented Ram Wing in Ground Effect (3차원 PAR WIG (Powder Augmented Ram Wing in Ground Effect) 의 수치연구)

  • 곽승현
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.55-64
    • /
    • 1997
  • A wing operating in close proximity to the ground exhibits a reduction in induced drag, which increase the lift/drag ratio. The poert-augmented ram (RAR) phenomenon involves directiing the efflux from forward mounted propulsion ststem under the wings, with the efflux nearly stagnated under the wings. In the present paper, 3 dimentional PAR was numerically studied by solving the Navier-Stokes equations. Pressure distribution and velocity vectors are calculated around the wing surface and the ground. Through the numerical simulation, Cp values and lift/drag ratio are carefully reviewed by changing the height/chord; 0.05, 0.1, 0.3 and 0.8. The shape of model is NACA 0012 with a span/chord ratio of 3.0. According to the numerical results, the relationship between lift/drag and height/chord is fairly reasonable.

  • PDF

A Study On the Impulse Response Behavior of Ground Rods in Power Distribution System (22.9kV-Y 다중접지 배전계통 접지극의 임펄스 응답 특성 실증연구)

  • Kang, Moon-Ho;Jang, Sang-Ok;Park, Sang-Man;Ha, Dong-Hyuk;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1858-1860
    • /
    • 2003
  • Ground rods as the discharge path are commonly installed to ensure the safety of human beings and facilities from the surge. Accordingly, proper grounding resistance are specified by the grounding types, and the specified resistance are also required to install the lightning protective facilities. it is needed to analyze the difference between these two resistance through the field test. Therefore, in this paper, the impulse response behavior of the ground rods is analyzed by constructing the test facilities and by testing the ground rods in multi-ground power distribution systems. The impulse responses were analyzed, in transient state, by testing the concrete poles as well since the grounding wires are installed in the concrete poles.

  • PDF

Seismic Fragility Analysis of NPP Components for High Frequency Ground Motions (고진동수 지진동에 대한 원전 기기의 지진취약도 분석)

  • 최인길;서정문;전영선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.110-117
    • /
    • 2003
  • The result of recent seismic hazard analysis indicates that the ground motion response spectra for Korean nuclear power plant site have relatively large high frequency acceleration contents. In the ordinary seismic fragility analysis of nuclear power plant structures and equipments, the safety margin of design ground response spectrum is directly used as a response spectrum shape factor. The effects of input response spectrum shape on the floor response spectrum were investigated by performing the direct generation of floor response spectrum from the ground response spectrum. The safety margin included in the design ground response spectrum should be considered as a floor response spectrum shape factor for the seismic fragility analysis of the equipments located in a building.

  • PDF

Optimum Elevation Angle Control of the Receiving Antenna for the Long Distance Air-Ground Common Data Link (장거리 공중-지상 영상정보용 데이터링크의 수신 안테나 최적 고각 제어 방법)

  • Ryu, Young-jae;Ahn, Jae-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1528-1538
    • /
    • 2016
  • Common data link systems are designed to transmit the imaginary and signal intelligence data at long distance air-ground line of sight(LOS) link. In this paper, we analyze the received power variation according to the communication distance of the common data link using curved earth 2-Ray model suitable for received signal power analysis of long distance air-ground wireless channel. We propose optimal elevation angle control method of the receiving antenna to reduce a power variation caused by ground-reflected wave. Proposed method can get additional link margin compared to the conventional method without any additional hardware performance enhancement.

Response of Base Isolation System Subjected to Spectrum Matched Input Ground Motions (스펙트럼 적합 입력지반운동에 의한 면진구조의 응답 특성)

  • Kim, Jung Han;Kim, Min Kyu;Choi, In-Kil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.89-95
    • /
    • 2013
  • Structures in a nuclear power system are designed to be elastic even under an earthquake excitation. However a structural component such as an isolator shows inelastic behavior inherently. For the seismic assessment of nonlinear structures, response history analysis should be performed. In this study, the response of base isolation system was analyzed by response history analysis for the seismic performance assessment. Firstly, several seismic assessment criteria for a nuclear power plant structure were reviewed for the nonlinear response history analysis. Based on these criteria, the spectrum matched ground motion generation method modifying a seed earthquake ground motion time history was adjusted. Using these spectrum matched accelerograms, the distribution of displacement responses of the simplified base isolation system was evaluated. The resulting seismic responses excited by the modified ground motion time histories and the synthesized time history generated by stochastic approach were compared. And the response analysis of the base isolation system considering the different intensities in each orthogonal direction was performed.

A Study on the Possibility of Electrical Fires due to the Short Circuit and Ground Fault of Power Cable Supported by an Iron Fence (철제펜스로 지지된 동력배선의 단락.지락에 의한 전기화재 발생 개연성 연구)

  • Kim, Jeong-Hun;Park, Byoung-Ki;Song, Jong-Hyeok;Jung, Ki-Chang
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.41-45
    • /
    • 2007
  • Short circuit and ground fault account for the primary causes of electrical fires. In this research, real-scale experiments were conducted to assess the possibility of electrical fires due to these causes. The experiment conditions were identical with an actual fire accident, in which the power cable was supported by an iron fence. The purposes of this research are to investigate the short circuit caused by wire cutting, the conductivity of the iron fence depending on its coating conditions, and the ground fault of one wire or two wires in an effort to reconstruct the fire accident. The test results show that, owing to the instant operation of circuit breaker in the moment of short circuit or ground fault, the generated ignition energy is far less than necessary to start an ignition. Therefore it is concluded that electrical fire is highly unlikely if the electric system is protected by a circuit breaker with normal functions.

Improved Characteristic of Radiated Emission of a PCB by Using the Via-Hole Position (단일 비아 위치를 이용한 PCB의 복사성 방사 성능 향상)

  • Kim, Li-Jin;Lee, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1272-1278
    • /
    • 2009
  • The cancellation method of P/G(power/ground) plane resonances which are generated between the power plane and the ground plane in a 4-layer PCB(Printed Circuit Boards) with a via-hole for the improvement of the RE(Radiated Emission) characteristic is presented. The validity of the proposed method was confirmed from simulation and measurement of performances of signal transmission characteristic, intensities of edge-radiation and radiated emission of PCB with a via-hole.

Viaduct seismic response under spatial variable ground motion considering site conditions

  • Derbal, Rachid;Benmansour, Nassima;Djafour, Mustapha;Matallah, Mohammed;Ivorra, Salvador
    • Earthquakes and Structures
    • /
    • v.17 no.6
    • /
    • pp.557-566
    • /
    • 2019
  • The evaluation of the seismic hazard for a given site is to estimate the seismic ground motion at the surface. This is the result of the combination of the action of the seismic source, which generates seismic waves, the propagation of these waves between the source and the site, and site local conditions. The aim of this work is to evaluate the sensitivity of dynamic response of extended structures to spatial variable ground motions (SVGM). All factors of spatial variability of ground motion are considered, especially local site effect. In this paper, a method is presented to simulate spatially varying earthquake ground motions. The scheme for generating spatially varying ground motions is established for spatial locations on the ground surface with varying site conditions. In this proposed method, two steps are necessary. Firstly, the base rock motions are assumed to have the same intensity and are modelled with a filtered Tajimi-Kanai power spectral density function. An empirical coherency loss model is used to define spatial variable seismic ground motions at the base rock. In the second step, power spectral density function of ground motion on surface is derived by considering site amplification effect based on the one dimensional seismic wave propagation theory. Several dynamics analysis of a curved viaduct to various cases of spatially varying seismic ground motions are performed. For comparison, responses to uniform ground motion, to spatial ground motions without considering local site effect, to spatial ground motions with considering coherency loss, phase delay and local site effects are also calculated. The results showed that the generated seismic signals are strongly conditioned by the local site effect. In the same sense, the dynamic response of the viaduct is very sensitive of the variation of local geological conditions of the site. The effect of neglecting local site effect in dynamic analysis gives rise to a significant underestimation of the seismic demand of the structure.

Analysis of Split Power/Ground Plane Structures for Radiated EMI Reduction (EMI 저감을 위해 분할된 전원/접지 평판 구조에서의 방사성 방출 분석)

  • Lee, Jang-Hoon;Lee, Pil-Soo;Lee, Tae-Heon;Kim, Chang-Gyun;Song, In-Chae;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.6
    • /
    • pp.43-50
    • /
    • 2010
  • In this paper, we analyzed radiated emission generated by the split power/ground plane structures in order to reduce EMI in system modules. The magnetic fields and electric fields were simulated and measured on the test boards under various conditions. In order to reduce radiated emission, we have to determine spacing and location of the split ground gap so that input signal frequency does not coincide with the resonance frequency of the split power/ground plane structure and the phase of reflection coefficient is close to $0^{\circ}$ at input signal frequency. Moreover, we found that inserting a stitching capacitor could reduce the radiated emission. Low magnitude of reflection coefficient and the phase close to $0^{\circ}$ are required to reduce radiated emission. It is necessary to properly decide value and location of a stitching capacitor to fulfil those requirements.