• Title/Summary/Keyword: Positron-Emission Tomography (PET)

Search Result 482, Processing Time 0.024 seconds

A Case Report of Patient with Left Neck Mass and a History of Thyroid and Ovarian Cancer in Head and Neck (갑상선암 및 난소암 병력을 가진 좌측 경부 종물을 주소로 내원한 환자 1례에 대한 증례 보고)

  • Jeong, Yong Jun;Oh, Kyoung Ho;Kwon, Soon Young
    • Korean Journal of Head & Neck Oncology
    • /
    • v.36 no.2
    • /
    • pp.73-77
    • /
    • 2020
  • Ovarian cancer is common malignant disease with high mortality in the female. However, lymph node metastasis in the head and neck of ovarian cancer is very rare than in para-aortic, pelvic lymph node. A 49-year-old female patient came to our clinic with a left neck mass. After total thyroidectomy and left selective neck dissection for the cervical neck level II, III, IV, V, VI for ovarian cancer and thyroid cancer, she had already undergone chemotherapy (Paclitaxel+Carboplatin) 18 month ago. CT scan showed only lymph node enlargement in left neck level II. Positron emission tomography-computed tomography (PET-CT) revealed a hypermetabolic lesion in same area but no other hypermetabolic lesion, especially in the pelvic and abdominal cavity. Fine needle aspiration cytology revealed metastatic carcinoma. The serum level of CA-125 was elevated to 43.8U/mL, whereas other tumor markers (CA 19-9, CEA) were in the normal range. She underwent a revision of selective neck lymph node dissection for the cervical neck levels I, II, and III, and on the review of surgical pathology, metastatic carcinoma was suspected. Thus, we performed immunohistochemical staining for the tissue; as a result, it was finally diagnosed as metastatic ovarian cancer (positive for CK7, ER and PR, and negative for CK20). Adjuvant chemotherapy (Paclitaxel+Carboplatin) was planned on the tumor board, and the patient successfully received chemotherapy.

Virtual lymph node analysis to evaluate axillary lymph node coverage provided by tangential breast irradiation

  • Park, Shin-Hyung;Kim, Jae-Chul;Lee, Jeong Eun;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.33 no.1
    • /
    • pp.50-56
    • /
    • 2015
  • Purpose: To investigate the coverage of axillary lymph node with tangential breast irradiation fields by using virtual lymph node (LN) analysis. Materials and Methods: Forty-eight women who were treated with whole breast irradiation after breast-conserving surgery were analyzed. The axillary and breast volumes were delineated according to the Radiation Therapy Oncology Group (RTOG) contouring atlas. To generate virtual LN contours, preoperative fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scans with identifiable LN were fused with the CT scans, and the virtual LN contour were delineated on the CT. Results: The median level I and II axillary volume coverage percentages at the $V_{D95%}$ line were 33.5% (range, 5.3% to 90.4%) and 0.6% (range, 0.0% to 14.6%), respectively. Thirty-one LNs in 18 patients were delineated (26 in level I and 5 in level II). In the level I axilla, 84.6% of virtual LNs were encompassed by the 95% isodose line. In the level II axilla, by contrast, none of the virtual LNs were encompassed by the 95% isodose volumes. There was a substantial discrepancy between the RTOG contouring atlas-based axillary volume analysis and the virtual LN analysis, especially for the level I axillary coverage. The axillary volume coverage was associated with the body mass index (BMI) and breast volume. Conclusion: The tangential breast irradiation did not deliver adequate therapeutic doses to the axillary region, particularly those in the level II axilla. Patients with small breast volumes or lower BMI showed reduced axillary coverage from the tangential breast fields. For axillary LN irradiation, individualized anatomy-based radiation fields for patients would be necessary.

Case Report of the Pancreatic Cancer Patient after Pancreatoduodenectomy who is Taking the HangAm-Plus to Anti-metastasis and Preventing Recurrence (췌장암의 외과적 절제술 후 항암플러스로 항전이 및 재발 방지 중인 환자 증례보고)

  • Kim, Jong-Min;Park, Jae-Woo;Yoo, Hwa-Seung;Lee, Yeon-Weol;Cho, Chong-Kwan
    • Journal of Korean Traditional Oncology
    • /
    • v.16 no.1
    • /
    • pp.33-39
    • /
    • 2011
  • Objective : To investigate the anti-metastasis and preventing relapses of HangAm-Plus (HAP) on pancreatic cancer patient. Methods : A 49 year old male patient diagnosed with pancreatic cancer (T3N0M0) was admitted to EWCC (East-West Cancer Center) on Jul. 21st 2008. He had operated pylorus preserving pancreatoduodenectomy (PPPD) and came to the anti-metastasis and preventing relapses on pancreatic cancer patient. The patient was treated with HangAm-Plus (HAP) (3,000 mg/day) for the period of 33 months from Jul. 21st, 2008 to Apr. 7th, 2011. Tumor markers (CEA and CA19-9) were used to evaluate the disease progression of the patient. Positron Emission Tomography (PET) and Computed Tomography (CT) were also followed up. Results : HAP treatment was well tolerated by the patient. Patient has shown 33 months of disease free survival until now. Conclusion : This case study supports HAP's potential efficacy in the anti-metastasis and preventing relapses of pancreatic cancer patient.

Recent Research Trend in Lateral Flow Immunoassay Strip (LFIA) with Colorimetric Method for Detection of Cancer Biomarkers (암 바이오마커 검출용 비색법 기반 측면 흐름 면역 크로마토그래피 분석법(LFIA) 스트립의 최신 연구 동향)

  • Lee, Sooyoung;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.585-590
    • /
    • 2020
  • Successful early diagnosis of cancer diseases such as lung, prostate, liver and adrenocortical carcinoma is a key step in determining the cost of treatment, survival rate, and cure rate. Most of current cancer diagnosis systems including biopsy, computed tomography (CT), positron emission tomography (PET)-CT, magnetic resonance imaging (MRI), ultrasonography, etc., require expensive and complicated equipment with highly trained human resources. Global medical and scientific communities have thus made numerous efforts on developing effective but rapid disease management system via introducing a wide spectrum of point-of-care medical diagnosis devices. Among them, a lateral flow immunoassay strip technique has gained a great attention due to many advantages such as cost-effectiveness, short inspection time, and user friendly accessibility. In this mini-review, we will highlight recent research trend on the development of colorimetry based LFIA strips for cancer diagnosis and discuss the future research direction and potential applications.

Comprehensive Updates in the Role of Imaging for Multiple Myeloma Management Based on Recent International Guidelines

  • Koeun Lee;Kyung Won Kim;Yousun Ko;Ho Young Park;Eun Jin Chae;Jeong Hyun Lee;Jin-Sook Ryu;Hye Won Chung
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1497-1513
    • /
    • 2021
  • The diagnostic and treatment methods of multiple myeloma (MM) have been rapidly evolving owing to advances in imaging techniques and new therapeutic agents. Imaging has begun to play an important role in the management of MM, and international guidelines are frequently updated. Since the publication of 2015 International Myeloma Working Group (IMWG) criteria for the diagnosis of MM, whole-body magnetic resonance imaging (MRI) or low-dose whole-body computed tomography (CT) and 18F-fluorodeoxyglucose positron emission tomography/CT have entered the mainstream as diagnostic and treatment response assessment tools. The 2019 IMWG guidelines also provide imaging recommendations for various clinical settings. Accordingly, radiologists have become a key component of MM management. In this review, we provide an overview of updates in the MM field with an emphasis on imaging modalities.

Undifferentiated Pleomorphic Sarcoma of the Thoracic Aorta Presenting with Ruptured Saccular Aneurysm: A Case Report (소낭성 동맥류 파열로 발현된 흉부 대동맥에서 기원한 미분화성 다형성 육종: 증례 보고)

  • Do Woo Kim;Young Hwan Kim;Ung Rae Kang;Jun Woo Cho;Jae Seok Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1204-1209
    • /
    • 2020
  • Cases of undifferentiated pleomorphic sarcoma of the thoracic aorta are rare, and usually present with embolic events, renovascular hypertension, or back pain. Mural-based undifferentiated pleomorphic sarcomas that present as ruptured saccular aneurysms are extremely rare and are difficult to differentiate from mycotic aneurysms or penetrating atherosclerotic ulcers. Herein, we report a case of histopathologically proven undifferentiated pleomorphic sarcoma arising from the wall of the descending thoracic aorta that manifested as a mass after thoracic endovascular aortic repair for the treatment of a ruptured saccular aneurysm. We present findings obtained by CT and PET to provide helpful information for the accurate diagnosis and appropriate treatment of future cases.

A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET (N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구)

  • Kim, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Ju, Hee-Kyung;Kim, Yong-Jin;Kim, Byung-Tae;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two-compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE $Advance^{TM}$ PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by the refined method incorporating myocardium geometric information into the two-compartment model using N-13 ammonia and PET.

  • PDF

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Prognostic Usefulness of Maximum Standardized Uptake Value on FDG-PET in Surgically Resected Non-small-cell Lung Cancer (수술로 제거된 비소세포폐암의 예후 예측에 있어 FDG-PET 최대 표준화 섭취계수의 유용성)

  • Nguyen Xuan Canh;Lee Won-Woo;Sung Sook-Whan;Jheon Sang-Hoon;Kim Yu-Kyeong;Lee Dong-Soo;Chung June-Key;Lee Myung-Chul;Kim Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.205-210
    • /
    • 2006
  • Purpose: FDG uptake on positron omission tomography (PET) has been considered a prognostic indicator in non-small cell lung cancer (NSCLC). The aim of this study was to assess the clinical significance of maximum value of SUV (maxSUV) in recurrence prediction in patients with surgically resected NSCLC. Materials & methods: NSCLC patients (n=42, F:M =14:28, age $62.3{\pm}12.3$ y) who underwent curative resection after FDG-PET were enrolled. Twenty-nine patients had pathologic stage 1, and 13 had pathologic stage II. Thirty-one patients were additionally treated with adjuvant oral chemotherapy. MaxSUVs of primary tumors were analyzed for correlation with tumor recurrence and compared with pathologic or clinical prognostic indicators. The median follow-up duration was 16 mo (range, 3-26 mo). Results: Ten (23.8%) of the 42 patients experienced recurrence during a median follow-up of 7.5 mo (range, 3-13 mo). Univariate analysis revealed that disease-free survival (DFS) was significantly correlated with maxSUV (<7 vs. $\geq7$, p=0.006), tumor size (<3 cm vs. $\geq3$ cm, p=0.024), and tumor tell differentiation (well/moderate vs. poor, p=0.044). However, multivariate Cox proportional analysis identified maxSUV as the single determinant for DFS (p=0.014). Patients with a maxSUV of $\geq7$(n=10) had a significantly lower 1-year DFS rate (50.0%) than those with a maxSUV of <7 (n=32, 87.5%). Conclusion: MaxSUV is a significant independent predictor for recurrence in surgically resected NSCLC. FDG uptake can be added to other well-known factors in prognosis prediction of NSCLC.

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF