• Title/Summary/Keyword: Positive sequence

Search Result 871, Processing Time 0.026 seconds

LIMSUP RESULTS FOR THE INCREMENTS OF PARTIAL SUMS OF A RANDOM SEQUENCE

  • Moon, Hee-Jin;Choi, Yong-Kab
    • East Asian mathematical journal
    • /
    • v.24 no.3
    • /
    • pp.251-261
    • /
    • 2008
  • Let {${\xi}_j;j\;{\geq}\;1$} be a centered strictly stationary random sequence defined by $S_0\;=\;0$, $S_n\;=\;\Sigma^n_{j=1}\;{\xi}_j$ and $\sigma(n)\;=\;33\sqrt {ES^2_n}$ where $\sigma(t),\;t\;>\;0$, is a nondecreasing continuous regularly varying function. Suppose that there exists $n_0\;{\geq}\;1$ such that, for any $n\;{\geq}\;n_0$ and $0\;{\leq}\;{\varepsilon}\;<\;1$, there exist positive constants $c_1$ and $c_2$ such that $c_1e^{-(1+{\varepsilon})x^2/2}\;{\leq}\;P\{\frac{{\mid}S_n{\mid}}{\sigma(n)}\;{\geq}\;x\}\;{\leq}\;c_2e^{-(1-{\varepsilon})x^2/2$, $x\;{\geq}\;1$ Under some additional conditions, we investigate some limsup results for the increments of partial sum processes of the sequence {${\xi}_j;j\;{\geq}\;1$}.

  • PDF

THE SEQUENTIAL ATTAINABILITY AND ATTAINABLE ACE

  • Kang, Buhyeon
    • Korean Journal of Mathematics
    • /
    • v.26 no.4
    • /
    • pp.757-775
    • /
    • 2018
  • For any non-negative real number ${\epsilon}_0$, we shall introduce a concept of the ${\epsilon}_0$-dense subset of $R^m$. Applying this concept, for any sequence {${\epsilon}_n$} of positive real numbers, we also introduce the concept of the {${\epsilon}_n$}-attainable sequence and of the points of {${\epsilon}_n$}-attainable ace in the open subset of $R^m$. We also study the characteristics of those sequences and of the points of {${\epsilon}_n$}-dense ace. And we research the conditions that an {${\epsilon}_n$}-attainable sequence has no {${\epsilon}_n$}-attainable ace. We hope to reconsider the social consideration on the ace in social life by referring to these concepts about the aces.

Protection for a Wind Turbine Generator in a Large Wind Farm

  • Zheng, Tai-Ying;Kim, Yeon-Hee;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.466-473
    • /
    • 2011
  • This paper proposes a protection algorithm for a wind turbine generator (WTG) in a large wind farm. To minimize the outage section, a protection relay for a WTG should operate instantaneously for an internal fault or a connected feeder fault, whereas the relay should not operate for an internal fault of another WTG connected to the same feeder or an adjacent feeder fault. In addition, the relay should operate with a delay for an inter-tie fault or a grid fault. An internal fault of another WTG connected to the same feeder or an adjacent feeder fault, where the relay should not operate, is determined based on the magnitude of the positive sequence current. To differentiate an internal fault or a connected feeder fault from an inter-tie fault or a grid fault, the phase angle of the negative sequence current is used to distinguish a fault type. The magnitude of the positive sequence current is then used to decide either instantaneous operation or delayed operation. The performance of the proposed algorithm is verified under various fault conditions with EMTP-RV generated data. The results indicate that the algorithm can successfully distinguish instantaneous operation, delayed operation, or non-operation depending on fault positions and types.

Development and evaluation of semi-nested PCR for detection of the variable lipoprotein haemagglutinin (vlhA) gene of Mycoplasma Synoviae in chicken

  • Pohuang, Tawatchai;Phuektes, Patchara;Junnu, Sucheeva
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.3
    • /
    • pp.109-116
    • /
    • 2020
  • This study aimed to develop a semi-nested polymerase chain reaction assay for the direct detection of Mycoplasma synoviae (M. synoviae) from clinical samples using three newly designed oligonucleotide primers specific to the variable lipoprotein haemagglutinin (vlhA) gene and differentiate M. synoviae field strains based on a nucleotide deletion or the insertion of the proline-rich repeat (PRR) region of the vlhA gene. The developed semi-nested polymerase chain reaction (PCR) assay revealed positive results in 12 out of 100 clinical samples collected from chickens showing lameness and joint swelling. Six positive samples were selected randomly for sequencing, and sequence analysis revealed 96.3-100% nucleotide identities compared to the reference sequences. Phylogenetic analysis showed that sequences of the strains in this study were closely related to WVU1853 (Spain), CK.MS.UDL.PK.2014.2 (Pakistan), and F10-2AS (USA) strains, but they were distinct from the M. synoviae-H vaccine strain sequence. M. synoviae obtained from these samples were identified as types A and C with a length of 38 and 32 amino acids, respectively. These results indicated that the specific and sensitive semi-nested PCR could be a useful diagnostic tool for the direct identification of clinical samples, and the sequence analysis of the partial vlhA gene can be useful for typing M. Synoviae.

Control Strategy for Three-Phase Grid-Connected Converters under Unbalanced and Distorted Grid Voltages Using Composite Observers

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.469-478
    • /
    • 2013
  • This paper proposes a novel scheme for the current controller for the grid-side converter (GSC) of permanent-magnet synchronous generator (PMSG) wind turbines to eliminate the high-order harmonics in the grid currents under grid voltage disturbances. The voltage unbalance and harmonics in three-phase systems cause grid current distortions. In order to mitigate the input current distortions, multi-loop current controllers are applied, where the positive-sequence component is regulated by proportional-integral (PI) controllers, and the negative-sequence and high-order harmonic components are regulated by proportional-resonance (PR) controllers. For extracting the positive/negative-sequence and harmonic components of the grid voltages and currents without a phase delay or magnitude reduction, composite observers are applied, which give faster and more precise estimation results. In addition, an active damping method using PR controllers to damp the grid current component of the resonant frequency is employed to improve the operating stability of VSCs with inductor-capacitor-inductor (LCL) filters. The validity of the proposed method is verified by simulation and experimental results.

Replication and packaging of Turnip yellow mosaic virus RNA containing Flock house virus RNA1 sequence

  • Kim, Hui-Bae;Kim, Do-Yeong;Cho, Tae-Ju
    • BMB Reports
    • /
    • v.47 no.6
    • /
    • pp.330-335
    • /
    • 2014
  • Turnip yellow mosaic virus (TYMV) is a spherical plant virus that has a single 6.3 kb positive strand RNA as a genome. In this study, RNA1 sequence of Flock house virus (FHV) was inserted into the TYMV genome to test whether TYMV can accommodate and express another viral entity. In the resulting construct, designated TY-FHV, the FHV RNA1 sequence was expressed as a TYMV subgenomic RNA. Northern analysis of the Nicotiana benthamiana leaves agroinfiltrated with the TY-FHV showed that both genomic and subgenomic FHV RNAs were abundantly produced. This indicates that the FHV RNA1 sequence was correctly expressed and translated to produce a functional FHV replicase. Although these FHV RNAs were not encapsidated, the FHV RNA having a TYMV CP sequence at the 3'-end was efficiently encapsidated. When an eGFP gene was inserted into the B2 ORF of the FHV sequence, a fusion protein of B2-eGFP was produced as expected.

Compensation of Source Voltage Unbalance and Current Harmonics in Series Active and Shunt Passive Power Filters

  • Lee G-Myoung;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.586-590
    • /
    • 2001
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for hybrid active power filters is proposed, where no low/high-pass filters are used in compensation voltage composition. The phase angle and compensation voltages for source harmonic current and unbalanced voltage components are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. Since a balanced set of the source voltage obtained by scaling the positive sequence components is used as reference values for source current and load voltage, it is possible to eliminate the necessity of low/high-pass filters in the reference generation. Therefore the control algorithm is much simpler and gives more stable performance than the conventional method. In addition, the source harmonic current is eliminated by compensating for the harmonic voltage of the load side added to feedback control of the fundamental component.

  • PDF

On a functional central limit theorem for the multivariate linear process generated by positively dependent random vectors

  • KIM TAE-SUNG;BAEK JONG IL
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2000.11a
    • /
    • pp.119-121
    • /
    • 2000
  • A functional central limit theorem is obtained for a stationary multivariate linear process of the form $X_t=\sum\limits_{u=0}^\infty{A}_{u}Z_{t-u}$, where {$Z_t$} is a sequence of strictly stationary m-dimensional linearly positive quadrant dependent random vectors with $E Z_t = 0$ and $E{\parallel}Z_t{\parallel}^2 <{\infty}$ and {$A_u$} is a sequence of coefficient matrices with $\sum\limits_{u=0}^\infty{\parallel}A_u{\parallel}<{\infty}$ and $\sum\limits_{u=0}^\infty{A}_u{\neq}0_{m{\times}m}$. AMS 2000 subject classifications : 60F17, 60G10.

  • PDF

A Comparative Study of Frequency Estimation Techniques using High Speed FIR Filter and Phasor Angle between Two Phasors (고속 FIR 필터와 두 페이저 위상을 이용한 주파수 추정 알고리즘의 비교 연구)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.122-129
    • /
    • 2009
  • Frequency is an important operating parameter of a power system. It is essential that the frequency of a power system be maintained very close to its nominal frequency. And frequency measurement devices have need to measure a fast and accurate of frequency using voltage signals. This paper proposes a comparative study of frequency estimation techniques using the high speed FIR filter based algorithm, the DFT filter based algorithm using phasor angle between two phasors, and positive sequence component based algorithm using the half angle between two successive positions of phasor. The discussed three techniques have been formed through numerical manipulation of a discrete system. The proposed techniques have been tested using signals obtained from selected power system model using ATP simulation package. Some test results are shown in this paper.

Modeling and Analysis of PMSMs under Inter Turn Short Faults

  • Choi, Jun-Hyuk;Gu, Bon-Gwan;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1243-1250
    • /
    • 2013
  • A model of a permanent magnet synchronous motor (PMSM) with an inter turn short fault is proposed using a deformed flux model. The deformed flux model includes not only the fault winding flux information but also the inductance variation of the healthy winding considering the configuration of the winding distribution. With the deformed flux model and the positive sequence current assumption, the proposed model is derived in the positive and negative sequence synchronous reference frame (SRF). The finite elements method (FEM) simulation is applied to validate the proposed PMSM model with inter turn short fault.