• 제목/요약/키워드: Position reliability

검색결과 675건 처리시간 0.028초

Reliability of the Foot Posture Index (FPI-6) for Assessment of Stroke Patients

  • Lee, Jong Dae;Kim, Young Mi;Kim, Kyung;Koh, Da Hyun;Choi, Myeong Su;Lee, Ho Jung
    • The Journal of Korean Physical Therapy
    • /
    • 제27권5호
    • /
    • pp.311-314
    • /
    • 2015
  • Purpose: This study attempted to determine intra-rater reliability and inter-rater reliability for measurement of foot form using the FPI-6 (Foot Posture Index) in patients with hemiplegia caused by stroke. Methods: Twenty two stroke patients were recruited into the research and their foot posture was evaluated using the FPI. Two raters assessed 6 items sequentially in accordance with the FPI-6 manual. This procedure involved asking the subject to take several steps in-place, prior to settling into a comfortable stance position with double limb support. Subjects were instructed to stand still with their arms by their sides and look straight ahead. FPI-6 values ranged from -2 to +2 for each of the six criteria and from -12 to +12 for the total score, indicating a position for each foot either along the supinated (negative score) to pronated (more than +6) continuum of foot posture. Results: The results showed that intra-rater reliability and inter-rater reliability for a total FPI-6 score was high: 0.807-0.888. An almost perfect agreement between the two raters was identified in the foot's morphological classification (Somer's D=0.712; p<0.05). Intra-percentage agreement was high (88.6%). Conclusion: The FPI-6 is a quick, simple, and reliable clinical tool with demonstrated good to excellent intra-rater reliability and good inter-rater reliability when used in assessment of the stroke patient's foot.

Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position

  • Ha, Sung-Min;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.

일체형원자로 SMART의 제어봉 위치지시기 개발 (Development of Position Indicator for System-Integrated Reactor SMART)

  • 유제용;김지호;허형;김종인;장문희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.921-926
    • /
    • 2001
  • The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. In this study, a thorough investigation on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. A design of the control rod position indication system using reed switch for the CEDM on the system-integrated reactor SMART was developed based on the position indicator technology identified through the investigation. The feasibility of the design was evaluated by test of manufactured control rod position indicator using reed switch for SMART.

  • PDF

BGA형 반도체 패키지의 위치정렬용 영상처리기법 오차의 통계적 분석 방법 (A Statistical Analysis Method for Image Processing Errors in the Position Alignment of BGA-type Semiconductor Packages)

  • 김학만;성상만;강기호
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.984-990
    • /
    • 2013
  • Pick and placement systems need high speeds and reliability for the position alignment process of semiconductor packages in picking up and placing them on placement trays. Image processing is usually adopted for position aligning where finding out the most suitable method is considered most important aspect of the process. This paper proposes a method for judging the performance of different image processing algorithms based on the PCI (Process Capability Index). The PCI is an index which represents the error distribution acquired from many experimental data. The bigger the index, the more reliable the results or the lower the deviation. Two compared and candidate methods are Hough Transform and PCA (Principal Component Analysis), both of which are very suitable for oblong or rectangular type packages such as BGA's. Comparing the two approaches through a CPI with enough experimental results leads to the conclusion that the PCA is much better than the Hough Transform in not only reliability, but also processing speed.

실내 위치 인식 시스템에서의 위치 정보 관리를 위한 실시간 위치 데이터 관리 기법 (A realtime location positioning data management methods for location information managements in the indoor location awareness system)

  • 윤창표;황치곤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.278-279
    • /
    • 2015
  • 최근, 스마트 기기의 발전과 더불어 스마트 단말을 이용한 지능형 실내 위치 인식 서비스에 대한 관심이 증대되고 있다. 이때 실내 위치 측위 기술로서 BLE(Bluetooth Low Energy) 기술이 관심을 받고 있다. 그러나 방대한 위치 정보를 수신하는 스마트 단말에서 수집된 위치 정보의 신뢰성을 확인할 수 있는 방법은 없다. 이는 신호 간섭 등의 이유로 실내 위치 정보의 신뢰성가 떨어지기 때문이다. 본 논문에서는 iBeacon의 위치 정보로 부터 신뢰성 있는 위치 정보를 얻기 위해 수집된 빅 데이터의 관리 기법을 제안한다.

  • PDF

자가보고 능력이 없는 중환자의 통증사정을 위한 한국어판 Critical Care Pain Observation Tool의 신뢰도와 타당도 검증 (Reliability and Validity of a Korean Version of the Critical Care Pain Observation Tool (CPOT) for ICU Patients Unable to Self Report)

  • 이희옥;김연수;이창옥;허성이;권인각
    • 중환자간호학회지
    • /
    • 제6권1호
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: The purpose of this study was to examine the reliability and validity of a Korean version of the Critical Care Pain Observation Tool (CPOT) developed for assessment of pain in critically ill nonverbal patients. Methods: Data were collected from a convenience sample of 30 critically ill patients admitted to a medical ICU in a hospital. The CPOT was tested at before, during and 20 minutes after changing a position and suction. Upon establishment of content and translation equivalence between the English and Korean version of CPOT. Results: The interrater reliability was found to be acceptable with the kappa coefficients of .76-1. The construct validity of the pain scores were increased from 0.43 to 2.5 in changing a position (t=-8.60, p<.001)and 0.1 to 3.23 (t=-9.36, p<.001) in suctioning. The pain scores were decreased from 6.06 to 4.01 in changing a position (t=-10.19, p<.001) and 6.45 to 4.13 (t=-10.39, p<.001) in suctioning. The concurrent validity the correlations between pain scores and physiological indicators, and a increased in Heart rate before and after changing a position (r=.65, p<.001). Conclusion: The CPOT can be used as a reliable and valid measure to assess pain in critically ill nonverbal a medical ICU patients.

  • PDF

영구 자석형 스텝모터의 위치 검출 (A position Detector of Permanent Magnet Step Motors)

  • 원종수;정훈
    • 대한전기학회논문지
    • /
    • 제36권10호
    • /
    • pp.703-712
    • /
    • 1987
  • A position detection method for 2 phase bifilar permanent magnet step motors is proposed. The back emfgenerated on 2 phase windings by rotor permanent magnet is calculated using motor terminal voltage and current by analog circuit, and the rotor position output is obtained from tese back emf signals through some logical manipulation circuit. This position detector functionally acts like a 2 channel optical incremental encoder, and it is also shown by experimental results that it works well over wide range of speed or under resonant condition where the rotor rings around the detent position. Its resolution is twice of the number of steps per revolution. Bu software implemented on micro-processor, the reliability of position output is enhanced, detecting and correcting error dut to external and/ or internal noise.

서치코일을 이용한 단상 SRM의 구동 (Drive of Single-phase Switched Reluctance Motors Using Search Coils)

  • 신덕식;양형열;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.750-753
    • /
    • 2005
  • This paper presents a method of detecting rotor position for single phase Switched Reluctance Motors(SRMs) using searchs coil. In the single phase SRM, mainly Hall effect sensors or photo interrupters have been used to detect the rotor position. But these sensors cause high cost and increase the volume of the motor, Furthermore when the motor is used in very hostile environment like high temperature or pressure, its reliability goes down. In this paper, low cost and robust characteristics of rotor position detection method are focused in order to compensate for disadvantage of existing sensors. Search coils wound around the stator pole are used for detection of the rotor position in single phase SRM. Rotor position detection is achieved through electromotive force patterns induced by time-varying flux linkage in the search coil. The validity of the method is verified by experimental results.

  • PDF

Inter-rater Reliability of Cervical Proprioception, Dynamic Balance and Dorsiflexion Range of Motion Ising STARmat®

  • Park, Ji-Won;Park, Seol
    • The Journal of Korean Physical Therapy
    • /
    • 제32권2호
    • /
    • pp.88-93
    • /
    • 2020
  • Purpose: This study examined the inter-rater reliability of cervical proprioception, dynamic balance ability, and ankle dorsiflexion range of motion using STARmat®, which is a practical clinical tool that can provide practitioners and patients with quantitative and qualitative results. Methods: Thirty healthy young subjects were enrolled in this study, and two well-trained physical therapists participated as a tester. Two testers measured the cervical joint position error at the starting position after neck flexion, extension, side bending, and rotation; three dynamic balance tests, including anterior excursion, anterior reaching with single leg balance, and posterior diagonal excursion; and ankle dorsiflexion range of motion using STARmat®. The intra-class correlation coefficient (ICC) was used to determine the inter-rater reliability of the tests. Results: The inter-rater reliability for the cervical proprioception ranged from moderate to good (0.66 to 0.83), particularly for flexion (0.82), extension (0.70), right side bending (0.73), left side bending (0.71), right rotation (0.83), and left rotation (0.66). For the dynamic balance, the inter-rater reliability ranged from good to excellent (0.87 to 0.91), particularly for anterior excursion (0.86), posterior diagonal excursion (0.87 to 0.89), and anterior reaching with a single leg balance (0.90 to 0.91). In addition, for the ankle dorsiflexion range of motion, the ICC for the inter-rater reliability ranged from 0.95 to 0.96. Conclusion: STARmat® is a reliable tool for measuring cervical proprioception, dynamic balance tests, and ankle dorsiflexion range of motion in healthy young adults.

계통계획 수위용 공급지장비의 추정방법 및 이의 응용에 관한 연구 (A Study on the Assessment and Application of Outage Cost for Power System Expansion Planning)

  • 최재석;강성록;트룬틴트란;김호용;김슬기
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.285-295
    • /
    • 2004
  • The outage cost assessment has an important position for determination of the optimal level or optimal range of reliability for power system expansion planning. Establishing the worth of service reliability is a very difficult and subjective task. While the utility cost(reliability cost) will generally increase as consumers are provided with higher reliability, the consumer costs(reliability worth) associated with supply interruptions will decrease as the reliability increases. The total costs to society are the sum of these two individual costs and the optimum or target level of reliability is achieved at minimum point of the total cost curve. This paper addresses the role, need and assessment algorithms and methodologies of the outage cost in power system expansion planning. In a case study, the outage cost has been assessed using macro approach for our country 15years(1986-200l) in the case study. Additionally, determination processing of optimum reliability level is presented in another case study with the five buses MRBTS.