• Title/Summary/Keyword: Position measurement

Search Result 2,295, Processing Time 0.031 seconds

Synthesis and Fungicidal Activities of Substituted Phenyl Hydrazono-3-Methyl-1, 2-Isoxazol-5-One Derivatives. (치환 Phenyl Hydrazono-3-Methyl-1, 2-Isoxazol-5-One 유도체의 합성과 살균활성)

  • Park, Kwang-Wook;Keum, Young-Su;Park, Chang-Kyu
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.2
    • /
    • pp.239-245
    • /
    • 1996
  • Fungicidal activity has been examined for a series of substituted phenylhydrazono-3-methyl-1,2-isoxazol-5-one against plant pathogenic fungi. 3-methyl isoxazol-5-one was obtained from ethyl acetoacetate and hydroxyl amine. Final products were prepared by aromatic diazo coupling with 3-methyl isoxazol-5-one. Fungicidal activities against Rhizoctonia solani, Colletotrichum gloeosporioides, Cladosporium cucumerinum, Pythium ultimum were tested and Pythium ultimum were tested and Pythium ultimum was selected for quantitative measurement of activity. Methyl, halogen, nitro derivatives possessed high fungicidal activity at p-, o-, p- position, respectively. Methyl, halogen derivatives were much more active than alkoxy, nitro derivatives and the order of activity of halogen derivatives was F > Cl > I. This result implied that the activity was related to the molecular volume of substitutents.

  • PDF

Developement of Safety Management System of Multi-Laborers Using RTLS in the Pavement and Bridge Construction Field (도로포장 및 교량 유지보수 현장에서 RTLS를 활용한 다중 노무자의 안전관리 시스템 개발)

  • Song, Ki-Il;Lim, Jin-Sun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Real time location system was development for safety management at road and bridge maintenance field. The system can check the real-time location detection, movement history, behavior of a number of laborers. The system consisted of a Bluetooth and ZigBee that uses low-power. It had a very large error that the previous method for the position recognition by triangulation using the RSSI. Because This study proposed a new distance measurement and correction scheme using RSSI and accelerometer. It was evaluated in the maintenance field. A development system were evaluated in the field, the results are shown an error between 0.2 m and 0.4 m. And through the acceleration of history it was confirmed by determining possible to determine the safety situation of the laborers.

Studies on effects of calibration methods and current lead position on the direct current potential drop method for crack length measurement (직류전압강하법에 의한 균열길이 측정에 미치는 도선의 위치 및 보정방법의 영향에 관한 연구)

  • Cho, C.C.;Kim, I.S.;Kim, S.S.;Choe, S.J.;Hur, B.Y.
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.300-306
    • /
    • 1997
  • The effective resolution of the direct current potential drop (DCPD) method for crack length determination is strongly affected by a number of factors including wire locations and calibration method. In the present study, the effects of wire locations, thermal EMF and reference probe locations on the accuracy of calibration methods, including Hicks-Pickard equation and Johnson's equation, were examined with the CT specimens which were nine times larger than the standard specimen. In light of experimental results, it was found that Hicks-Pickard equation can accurately represent the a/W-V/Vo relationship when current input wire is located at the load line. It was also found that the accuracy of DCPD method can be greatly improved with the thermal EMF calibration and the use of Vo value at a/W = 0.241. The use of reference potential was found to be impractical when current input wire is located at the load line.

  • PDF

Measurement of an Unsteady Boundary Layer of an Oscillating Airfoil at a Low Reynolds Number (저 레이놀즈수에서 진동하는 에어포일의 비정상 경계층 측정)

  • Kim, Dong-Ha;Jang, Jo-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.12
    • /
    • pp.9-17
    • /
    • 2006
  • An experimental study was carried out to examine the behavior of the unsteady boundary layer. An NACA 0012 airfoil with aspect ratio of 2.7 was set vertically in a test section, which is sinusoidally pitched about the quarter chord. The oscillating amplitude is from -6$^{\circ}$ to +6$^{\circ}$ and the mean angle of attack is 0$^{\circ}$. Surface mounted probes (Glue-on probes) were employed to measure the surface flow of the boundary layer. Measurements were made at free-stream velocities of 1.98, 2.83, and 4.03m/s, and the corresponding Reynolds numbers based on the chord length were 2.3$\times$104, 3.3$\times$104 and 4.8$\times$104, respectively. The reduced frequency is fixed as 0.1 in all cases. The results show that the surface position of minimum shear stress and of boundary layer break-down can be discerned in the Reynolds number between 2.3$\times$104 and 3.3$\times$104.

System Development of Precision Vision Measurement Using Fuzzy C-Means Algorithm (Fuzzy C-Means를 이용한 정밀 영상측정 시스템 개발)

  • 김석현
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.4
    • /
    • pp.7-14
    • /
    • 1999
  • The measuring systems of auto-parts are most of greater part very expensive. This paper tries to study to make a low-cost measuring equipment there's several kinds of parts in automobile. In this study, we take aircon-switch called magnet coil-housing as the object of measurements. The measurements of this product is currently in difficult situations at factory. In the case of the mesuring objects being big sizes and camera sensor having under 410000 pixels, the key point is the number of pixels not to be changed whenever the same object is measured under the same position. We modified and used fuzzy c-means algorithm to get mostly without the change of the numbers of pixels exactly. Also, the standardized ruler is necessary to measure the length of the object but it is not easy to get the precised ruler. Therefore, the standard length has been taken as the mean value of the pixels in the previous passed objects manually obtained at factory. The results are displayed on monitor and transferred these signals to the microprocessor through RSC-232 port to determine a good or bad of products.

  • PDF

Displacement Measurement of a Floating Structure Model Using a Video Data (동영상을 이용한 부유구조물 모형의 변위 관측)

  • Han, Dong Yeob;Kim, Hyun Woo;Kim, Jae Min
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.2
    • /
    • pp.159-164
    • /
    • 2013
  • It is well known that a single moving camera video is capable of extracting the 3-dimensional position of an object. With this in mind, current research performed image-based monitoring to establish a floating structure model using a camcorder system. Following this, the present study extracted frame images from digital camcorder video clips and matched the interest points to obtain relative 3D coordinates for both regular and irregular wave conditions. Then, the researchers evaluated the transformation accuracy of the modified SURF-based matching and image-based displacement estimation of the floating structure model in regular wave condition. For the regular wave condition, the wave generator's setting value was 3.0 sec and the cycle of the image-based displacement result was 2.993 sec. Taking into account mechanical error, these values can be considered as very similar. In terms of visual inspection, the researchers observed the shape of a regular wave in the 3-dimensional and 1-dimensional figures through the projection on X Y Z axis. In conclusion, it was possible to calculate the displacement of a floating structure module in near real-time using an average digital camcorder with 30fps video.

Measurement and Active Compensation for 3-DOF Motion Errors of an Air Bearing Stage with Magnetic Preloads (자기예압 공기베어링 스테이지의 3 자유도 운동오차 측정 및 능동 보정)

  • Ro, Seung-Kook;Kim, Soo-Hyun;Kwak, Yoon-Keun;Park, Chun-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.2
    • /
    • pp.109-117
    • /
    • 2009
  • This paper presents a linear air bearing stage with compensated motion errors by active control of preloads generated by magnetic actuators with combination of permanent and electromagnets. A 1-axis linear stage motorized with a linear motor with 240mm of travel range is built for verifying this design concept and tested its performances. The three motions of the table are controlled with four magnetic actuators driven by current amplifiers and a DSP based digital controller. Three motion errors were measured combined method with laser interferometer and two-probe method with $0.085{\mu}m$ of repeatability for straightness error. The measured motion errors were modeled as functions of the stage position, and compensation were carried out with feedforward control because the characteristics of the motion control with magnetic actuators are linear and independent for each degree-of-freedoms. As the results, the errors were reduced from $1.09{\mu}m$ to $0.11{\mu}m$ for the vertical motion, from 9.42 sec to 0.18 sec for the pitch motion and from 2.42 sec to 0.18 sec for roll motion.

IDENTIFICATION OF FALSIFIED DRUGS USING NEAR-INFRARED SPECTROSCOPY

  • Scafi, Sergio H.F.;Pasquini, Celio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3112-3112
    • /
    • 2001
  • Near-Infrared Spectroscopy (NIRS) was investigated aiming at the identification of falsified drugs. The identification is based on comparison of the NIR spectrum of a sample with a typical spectra of an authentic drug using multivariate modelling and classification algorithms (PCA/SIMCA). Two spectrophotometers (Brimrose - Luminar 2000 and 2030), based on acoustic-optical filter (AOTF) technology, sharing the same controlling computer, software (Brimrose - Snap 2.03) and the data acquisition electronics, were employed. The Luminar 2000 scans the range 850 1800 nm and was employed for transmitance/absorbance measurements of liquids with a transflectance optical bundle probe with total optical path of 5 mm and a circular area of 0.5 $\textrm{cm}^2$. Model 2030 scans the rage 1100 2400 nm and was employed for reflectance measurement of solids drugs. 300 spectra, acquired in about 20 s, were averaged for each sample. Chemometric treatment of the spectral data, modelling and classification were performed by using the Unscrambler 7.5 software (CAMO Norway). This package provides the Principal Component Analysis (PCA) and SIMCA algorithms, used for modelling and classification, respectively. Initially, NIRS was evaluated for spectrum acquisition of various drugs, selected in order to accomplish the diversity of physico-chemical characteristics found among commercial products. Parameters which could affect the spectra of a given drug (especially if presented as solid tablets) were investigated and the results showed that the first derivative can minimize spectral changes associated with tablet geometry, physical differences in their faces and position in relation to the probe beam. The effect of ambient humidity and temperature were also investigated. The first factor needs to be controlled for model construction because the ambient humidity can cause spectral alterations that should cause the wrong classification of a real drug if the factor is not considered by the model.

  • PDF

A Study on Discharge Characteristics from the Nozzle Orifice Attached to a Modularized Fire Extinguishing Gas-agent Container Under Horizontal Position (용기 일체형 가스소화 방식의 오리피스 방사 특성에 관한 연구)

  • 김윤증;윤명오;김상욱
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.59-69
    • /
    • 2002
  • The conventional fire extinguishing gas-agent system has a configuration in which the gas-agent comes out of a cylindrical container having vertically settled shape. However, in this study a horizontally installed container of a piping shape having a cylinder of the same shape with a cylinder valve and a discharge nozzle was used, and the relationship between orifice size of nozzle and discharge rate of gas-agent was investigated through various experiments including the measurement of discharge rate under different ambient-temperature conditions. In such experiments, HCFC Blend A was used without super-pressurization by nitrogen. From this research, it was observed that statutory discharge duration of 10 seconds can be met if the relatively large size of the valve and the nozzle orifice were properly selected.

System Development of Precision Vision Measurement Using Fuzzy C-means and Possibilistic C-Means Algorithm (Fuzzy C-means와 확률 C-Means를 결합한 정밀 영상측정 시스템 개발)

  • 김석현
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1999.12a
    • /
    • pp.315-323
    • /
    • 1999
  • The measuring systems of auto-parts are most of greater part very expensive. This paper tries to study to make a low-cost measuring equipment. There's several kinds of parts in automobile. In this study, we take aircon-switch called magnet coil-housing as the object of measurements. The measurements of this product is currently in difficult situations at factory. In the case of the mesuring objects being big sizes and camera sensor having under 410000 pixels, the key point is the number of pixels not to be changed whenever the same object is measured under the same position. We modified and used fuzzy c-means algorithm to get mostly without the change of the numbers of pixels exactly. Also, the standardized ruler is necessary to measure the length of the object but it is not easy to get the precised ruler. Therefore, the standard length has been taken as the mean value of the pixels in the previous passed objects manually obtained at factory. The results are displayed on monitor and transferred these signals to the microprocessor through RSC-232 port to determine a good or bad of products.

  • PDF