• Title/Summary/Keyword: Position Errors

Search Result 1,168, Processing Time 0.03 seconds

A Study on the Accuracy of the Loran-C Fix of Korean Chain in Pusan Area (부산지역에서의 Loran-C 한국체인의 측위정도에 관한 연구)

  • 박주삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.4
    • /
    • pp.372-380
    • /
    • 1996
  • The operation of Far East Chain(GRI 5970) of Loran - C system had been stopped on June, 1995, but that of Korean Chain(GRI 9930) of Loran - C system which was jointed with North West Pacific Chain(GRI 8930) and Russia Chain(GRI 7950) by international cooperation, was started on January 1996. In this paper, in order to study the accuracy of Loran - C fix of Korean Chain, the authors examined and analyzed the data of the reciever of Loran - C(LC -90, Furuno) and GPS(AccNav Sport super (TM), Eagle) measured automatically and continually for 2 seconds at interval of 5 minutes from November 22, 1992, to January 20, 1996 at the fixed position of National Fisheries University of Pusan, The results obtained were as follows ; 1)The mean time differences of M-W, M-X, and M-Y pair measured in the base observed position were 12333.09${\mu}$s, 28338.44${\mu}$s, and 42806.01${\mu}$s respectively and the mean standard deviations of that were 0.0121${\mu}$s, 0.0290${\mu}$s, and 0.0327${\mu}$s respectively. The daily and monthly variance forms of time difference at each pair appeared in a similar reappearance. 2)The mean standard deviations of the latitude and longitude by Loran - C were 9.1m and 17.4m in W.X pair, 11.5m and 13.7m in W.Y pair, and 8.1m and 29.3m in X.Y pair respectively, and then the probable radiuses within 95% of each pair were 39.2m, 35.7m, and 60.8m, respectively. Therefore, It is to be desired that W.Y par is selected to improve the accuracy in Pusan area. 3)The mean standard deviations of the latitude and longitude by GPS were 15.4m and 15.0m and the probable radius within 95% was 43.4m. 4)The position errors for GPS and each pair of Loran - C were 16.0m to the South in GPS and 265.2m to the East in W.X pair of Loran - C, 279.5m to the North in W.Y pair of that, and 224.3m to the North-West in X.Y pair of that, so GPS is about 250m higher than Loran - C in accuracy.

  • PDF

Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy (Image Guided Radiation Therapy (IGRT) 시 On Board Imager를 이용한 환자 Setup Error 보정평가)

  • Kang, Soo-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.69-81
    • /
    • 2008
  • Purpose: To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Materials and Methods: Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2∼3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. Results: General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head & Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head & Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. Conclusion: The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  • PDF

Comparing the dosimetric impact of fiducial marker according to density override method : Planning study (양성자 치료계획에서 fiducial marker의 density override 방법에 따른 선량변화 비교 : Planning study)

  • Sung, Doo Young;Park, Seyjoon;Park, Ji Hyun;Park, Yong Chul;Park, Hee Chul;Choi, Byoung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: The application of density override is very important to minimize dose calculation errors by fiducial markers of metal material in proton treatment plan. However, density override with actual material of the fiducial marker could make problem such as inaccurate target contouring and compensator fabrication. Therefore, we perform density override with surrounding material instead of actual material and we intend to evaluate the usefulness of density override with surrounding material of the fiducial marker by analyzing the dose distribution according to the position, material of the fiducial marker and number of beams. Materials and Method: We supposed that the fiducial marker of gold, steel, titanium is located in 1.5, 2.5, 4.0, 6.0 cm from the proton beam's end of range using water phantom. Treatment plans were created by applying density override with the surrounding material and actual material of the fiducial marker. Also, a liver cancer patient who received proton therapy was selected. We located the fiducial marker of gold, steel, titanium in 0, 1.5, 3.5 cm from the proton beam's end of range and the treatment plans were created by same method with water phantom. Homogeneity Index(HI), Conformity Index(CI) and maximum dose of Organ At Risk(OAR) in Planning Target Volume(PTV) as the evaluation index were compared according to the material, position of the fiducial marker and number of beam. Results: The HI value was more decreased when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Especially the HI value was increased when the fiducial marker was located farther from the proton beam's end of the range for a single beam and the fiducial marker's position was closer to isocenter for two or more beams. The CI value was close to 1 and OAR maximum dose was greatly reduced when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Conclusion: Density override with surrounding material can be expected to achieve more precise proton therapy than density override with actual material of the fiducial marker and could increase the dose uniformity and target coverage and reduce the dose to surrounding normal tissues for the small fiducial markers used in clinical practice. Most of all, it is desirable to plan the treatment by avoiding the fiducial marker of metal material as much as possible. However, if the fiducial marker have on the beam path, density override of the surrounding material can be expected to achieve more precise proton therapy.

  • PDF

Negative apparent resistivity in dipole-dipole electrical surveys (쌍극자-쌍극자 전기비저항 탐사에서 나타나는 음의 겉보기 비저항)

  • Jung, Hyun-Key;Min, Dong-Joo;Lee, Hyo-Sun;Oh, Seok-Hoon;Chung, Ho-Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.33-40
    • /
    • 2009
  • In field surveys using the dipole-dipole electrical resistivity method, we often encounter negative apparent resistivity. The term 'negative apparent resistivity' refers to apparent resistivity values with the opposite sign to surrounding data in a pseudosection. Because these negative apparent resistivity values have been regarded as measurement errors, we have discarded the negative apparent resistivity data. Some people have even used negative apparent resistivity data in an inversion process, by taking absolute values of the data. Our field experiments lead us to believe that the main cause for negative apparent resistivity is neither measurement errors nor the influence of self potentials. Furthermore, we also believe that it is not caused by the effects of induced polarization. One possible cause for negative apparent resistivity is the subsurface geological structure. In this study, we provide some numerical examples showing that negative apparent resistivity can arise from geological structures. In numerical examples, we simulate field data using a 3D numerical modelling algorithm, and then extract 2D sections. Our numerical experiments demonstrate that the negative apparent resistivity can be caused by geological structures modelled by U-shaped and crescent-shaped conductive models. Negative apparent resistivity usually occurs when potentials increase with distance from the current electrodes. By plotting the voltage-electrode position curves, we could confirm that when the voltage curves intersect each other, negative apparent resistivity appears. These numerical examples suggest that when we observe negative apparent resistivity in field surveys, we should consider the possibility that the negative apparent resistivity has been caused by geological structure.

Accuracy Analysis using Assistant Sensor Integration on Various IMU during GPS Signal Blockage (GPS 신호 단절 상황에서 IMU 사양에 따른 보조센서 통합을 이용한 정확도 분석)

  • Lee, Won-Jin;Kwon, Jay-Hyoun;Lee, Jong-Ki;Han, Joong-Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • In this study, the performances of a medium grade IMU which is aimed for Mobile Mapping System and a low grade IMU for pedestrian navigation are analyzed through simulations under GPS signal blockage. In addition, an analysis on the accuracy improvement of barometer, electronic compass, or multi-sensor(combination of barometer and electronic compass) to correct medium grade or low grade IMU errors in the situation of GPS signal blockage is performed. With the medium grade IMU, the three dimensional positioning error from INS exceeds the demanded accuracy of 5m when the block time is over 30 seconds. When we correct IMU with barometer, compass, or multi-sensor, however, the demanded accuracy is maintained up to 60 seconds. In addition, barometer is more effective than the electronic compass when they are combined. In case of low grade IMU like MEMS IMU, the three dimensional positioning error from INS exceeds the demanded accuracy of 20m when the block time is over 15 seconds. When we correct INS with barometer, compass, or multi-sensor, however, the demanded accuracy is maintained up to 15 seconds in simulation results. On the contrary to medium grade IMU, electronic compass is more effective than the barometer in case of low velocity such as pedestrian navigation. It is expected that the analysis suggested a method to decrease position or attitude error using aided sensor integration when MMS or pedestrian navigation is operated under 1he environment of GPS signal blockage.

Standardization of Underground Shopping Center Address System for the Three-Dimensional GIS-based Emergency Management (3차원 GIS기반의 소방방재를 위한 지하상가 주소체계 표준화)

  • Ha, Byeong Po;Kang, In Joon;Hong, Soon Heon;Park, Dong Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.63-69
    • /
    • 2014
  • Due to population growth and urban development in construction technology has expanded living space, underground construction as public transport as has been extended to the ground and underground urban traffic congestion increases. This underpass Stations sphere of influence this development was the center of the living space, space-time became a cultural space. However underpass ground space and time and space are enormous difficulties in contrast visibility due to smoke when light levels are low fire occurs, momentary loss of judgment errors due to a sense of orientation, rapid diffusion and ambient oxygen deficiency due to acquisition limitations, such as the Open resulting in property damage and personal injury. The purpose of this study is to analyze the existing system with respect to the address of the underground shopping center and system for presenting an address to the underground shopping mall in the basement of the straight and circular in connection with the street name address. Also can be known only to evacuate their citizens to address the position in the event of a fire inside the basement through the underground shopping mall address standardization system, the fire department only address exact location is being judged will be identified.

After retrospective evaluation of the SETUP rate change during the treatment of head and neck cancer patient with Helical Tomotherapy (두경부환자의 토모테라피 치료시 SETUP 변화율에 대한 후향적 평가)

  • Ha, Tae-young;Kim, Seung-jun;Hwang, Cheol-hwan;Son, Jong-gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • Purpose : Retrospective evaluation of setup changes using the corrected position during helical tomotherapy Materials and Methods : Head and neck cancer patients were randomly sampled and summarized into 3 groups: Group 1(32) Brain, Group 2 2(28)Maxillar, Nasal cavity, Group 3 (35) Nasopharynx(NPX), Tongue, Tonsil, and Oropharynx(OPX). In 3 groups, the statistical tests based on repeated measurements among 30 times of the duration of treatment by applying X, Y, Z axis errors, roll, weight changes, and vectors as variables. Results : The statistical test results showed that there was no difference between x-axis (p = 0.458) and y-axis (p=0.986) and in roll (p = 0.037), weight change (p <0.001), and the vector (p <0.001). In addition, the pattern between the three groups based on the fraction revealed no difference in x-axis (p = 0.430) and roll (p = 0.299) but a difference in y-axis (.023), weight change (p = 0.001), and vector (p = 0.028). Conclusion : The results of the retrospective evaluation found the change in the group 3 with respect Y, Z, weight, and vector and a larger random error during the treatment including low neck.

  • PDF

Orthographic Influence in the Perception and Production of English Intervocalic Consonants: A Pilot Study (영어 모음사이 자음의 인지와 발화에서 철자의 영향: 파일럿 연구)

  • Cho, Mi-Hui;Chung, Ju-Yeon
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.459-466
    • /
    • 2009
  • While Korean allows the same consonants at the coda of the preceding syllable and at the onset of the following syllable, English does not allow the geminate consonants in the same intervocalic position. Due to this difference between Korean and English, Korean learners of English tend to incorrectly produce geminate consonants for English geminate graphemes as in $su\underline{mm}er$. Based on this observation, a pilot study was designed to investigate how Korean learners of English perceive and produce English doubleton graphemes and singleton graphemes. Twenty Korean college students were asked to perform a forced-choice perception test as well as a production test for the 36 real word stimuli which consist of (near) minimal pairs of singleton and doubleton graphemes. The result showed that the accuracy rates for the words with singleton graphemes were higher than those for the words with doubleton graphemes both in perception and production because the subjects misperceived and misproduced the doubleton graphemes as geminates due to orthographic influence. In addition, the low error rates of the word with voiced stops were accounted for by Korean language transfer. Further, spectrographic analyses were provided where more production errors were witnessed in doubleton grapheme words than singleton grapheme words. Finally, pedagogical implications are provided.

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

An Analysis of folded cascode comarator by Single Event Transient(SET) (SET에 의한 folded cascode comparator 분석)

  • Jang, Jae-Seok;Chung, Jae-Pil;Park, Jung-Cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.2
    • /
    • pp.169-175
    • /
    • 2020
  • This paper studied the SET situation in VLSI because the electronic devices exposed to SET can indicate irregular operation and output errors. The SET environment was established using the exponential static wave (iexp) in the fold-cascode comparator. The comparator was experimented with how it affected it by the SET. In a folded comparator that did not enter the SET situation, the propagation delay was measured at 0.26㎲ and the gain was 0.649. The MOSFET close to the output stage was measured sensitively in the folded comparator that entered the SET situation. And propagation delay was calculated from 0.36 to 0.37㎲ and the gain was 0.649. The mid-position MOSFET was calculated from 0.28 to 0.30㎲ and the gain was 0.649. The MOSFET, which is farthest from the output stage from the folded comparator, was calculated with the propagation delay between 0.25 and 0.26㎲ and the gain of 0.649. In SET situations, the MOSFET close to the output portion of the folded comparator was sensitive. And at the MOSFET far from the output, the same results were obtained as a normal folded comparator without the SET input.