• Title/Summary/Keyword: Position Change

Search Result 2,636, Processing Time 0.032 seconds

The Effects of PNF Patterns on Trunk Muscle Activity According to Position Changes (자세변화에 따른 PNF 패턴이 체간 근육활성에 미치는 영향)

  • Kim, Kyung-Hwan;Youn, Hye-Jin;Park, Sung-Hun;Lim, Jin-Woo
    • PNF and Movement
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Purpose: The purpose of this study was to analyze the effects of proprioceptive neuromuscular facilitation (PNF) patterns on electromyography (EMG) activity in the rectus abdominis, internal abdominal oblique, external abdominal oblique, and erector spinae according to position changes. Methods: Ten healthy adults volunteered to participate in the study. The subjects were required to complete exercises that followed two PNF extremity patterns, namely, an upper extremity extension-adduction-internal rotation pattern and a lower extremity flexion-adduction-external rotation pattern. The exercises were applied in the supine, side-lying, and sitting positions. Repeated measure one-way ANOVA and post-hoc Bonferroni correction were used to determine the influence of the patterns on muscle activity for each muscle, and descriptive statistics were then used to determine the local/global muscle ratios. Results: The upper extremity pattern had a significant effect on the rectus abdominis and erector spinae in the supine position, and on the internal oblique and external oblique in the sitting position (p<0.05). The median value for the internal oblique/rectus abdominis showed a high ratio of 2.05, and a high ratio of 1.01 was shown for the internal oblique/external oblique in the sitting position. The lower extremity pattern had a significant effect on the rectus abdominis in the side-lying position and on the internal oblique, external oblique, and erector spinae in the sitting position (p<0.05). The median value for the internal oblique/rectus abdominis showed a high ratio of 2.83 in the sitting position and a high ratio of 1.30 for the internal oblique/external oblique in the side-lying position. Conclusion: The PNF pattern increases local muscle activation in an unstable position. Therefore, when the pattern is used for intervention purposes, trunk stability and varied position changes should be taken into account.

POSTOPERATIVE POSITIONAL CHANGE OF CONDYLE AFTER BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY ASSOCIATED WITH MANDIBULAR ASYMMETRY (하악골 비대칭 환자의 양측성 하악골 시상분할 골절단술 후 하악과두의 위치 변화)

  • Lee, Sung-Keun;Kim, Kyung-Wook;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.5
    • /
    • pp.359-367
    • /
    • 2004
  • Purpose: After the surgical correction with sagittal split ramus osteotomy, the position of the mandibular condyle in the glenoid fossa and the proximal segment of the mandible change because of bony gap between proximal and distal segment, especially in case of mandibular setback asymmetrically. In this study, positional changes in the condyle and proximal segment after BSSRO were estimated in the mandibular asymmetry patient by analyzing the in submentovertex view and P-A cephalogram for identification of ideal condylar position during surgery. Patients and Methods: The 20 patients were selected randomly who visit Dankook Dental Hospital for mandibular asymmetry. Bilateral sagittal split ramus osteotomy with rigid fixation was performed and P-A cephalogram and submentovertex view was taken at the time of preoperative, immediate postoperative, 3 month postoperative period. Results: Intercondylar length and transverse condylar angle was increased due to inward rotation of proximal segment and anteromedial rotation of lateral pole of condyle head. The condylar position had a tendency to return to the preoperative state and after 3 months return up to about half of the immediate post-operative changes, and all the results showed more changes in asymmetry patient and deviated part of the mandible. Conclusion: Based on all these results above, surgeon should make efforts to have a precise preoperative analysis and to have a ideal condylar position during rigid fixation after BSSRO.

Study on Error Correction of Impact Sound Position Estimation Using Ray Tracing (음선 추적을 이용한 폭발음 위치추정 오차 보정에 대한 연구)

  • Choi, Donghun;Go, Yeong-Ju;Lee, Jaehyung;Na, Taeheum;Choi, Jong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.89-96
    • /
    • 2016
  • TDOA(time delay of arrival) position estimate from acoustic measurement of artillery shell impact is studied in order to develop a targeting evaluation system. Impact position is calculated from the intersections of hyperbolic estimates based on the least square Taylor series method. The mathematical process of Taylor series estimation is known to be robust. However, the concern lays with the accuracy because it is sensitive to the bias caused by the randomness of measurement situation. The measurement error typically occurs from the distortion of waveform, change of travelling path, and sensor position error. For outdoor measurement, a consideration should be made on the atmospheric condition such as temperature and wind which can possibly change the trajectories of rays of sound. It produces wrong propagation time events accordingly. Ray tracing and optimization techniques are introduced in this study to minimize the bias induced by the ray of sound. The numerical simulation shows that the atmospheric correction improves the estimation accuracy.

Evaluation of measuring accuracy of body position sensor device for posture correction (자세교정을 위한 체위변환 감지 센서 디바이스의 정확성 평가)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Kang, Min-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.128-133
    • /
    • 2021
  • Recently Recently, the incidence of spinal diseases due to poor posture among students and office workers is increasing, and various studies have been conducted to help maintain correct posture. In previous studies, a membrane sensor or a pressure sensor was placed on the seat cushion to see the weight bias, or a sensor that restrained the user was attached to measure the position change. In our previous study, we developed a sensor device which can be easily attached to the body with an adhesive gel sheet and that measures and outputs the user's posture and body position in real time, but it has a limitation in the accuracy of the sensor value. In this study, a study was conducted to improve the performance of the position conversion sensor device and quantitatively evaluate the accuracy of the angle conversion measurement value, and a high accuracy with 2.53% of error rate was confirmed. In future research, it is considered that additional research targeting actual users is needed by diversifying posture correction training contents with multimedia elements added.

Extraction of the elemental images of object With variant perspectivity at computational integral imaging

  • Lee, Guen-Sik;Hwang, Yong-Seok;Kim, Eun-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1258-1260
    • /
    • 2009
  • Generally, if we want to change the perspectivity of objects, we should change the position of object or camera, forward or backward. In this paper, recognition of the perspectivity of objects is proposed by using a new elemental image array which is made change the pinhole points horizontally.

  • PDF

The Differences of Nitrous Oxide (N2O) Emissions as Crop Presence and Location of Gas Sampling Chambers in Upland (밭토양에서 챔버 위치와 작물체 유·무에 따른 아산화질소 배출량 차이 분석)

  • Jeong, Hyun Cheol;Choi, Eun Jung;Lee, Jong Sik;Kim, Gun Yeob;So, Kyu Ho
    • Journal of Climate Change Research
    • /
    • v.7 no.4
    • /
    • pp.427-432
    • /
    • 2016
  • Nitrous oxide is one of the main sources of greenhouse gases and its concentration has increased from 273 ppb in 1,750 to 315 ppb in 2005. Specially, nitrogen fertilizer used in agricultural soils is considered as an important source of atmospheric $N_2O$ emission. This study was conducted to estimate the difference of nitrous oxide emission as chamber position on furrow and ridge and crop existence in gas sampling chamber on upland. Four treatments used in this experiment were (1) no-fertilizer without crop in chamber on ridge, (2) fertilizer application without crop in chamber on ridge, (3) fertilizer application with crop in chamber on ridge, (4) fertilizer application without crop in chamber on ridge and furrow. Nitrous oxide emission at fertilizer application with crop in chamber on ridge were the highest while were the lowest at no-fertilizer without crop in chamber on ridge. There was no significant difference of nitrous oxide emission by chamber position, but total emission by crop existence in chamber was significant difference. Therefore, in order to estimate greenhouse gases emission using chamber method in upland, it should be considered in correlation with crop existence in chamber and characteristic changes like as the soil moisture, microbial flora by crop growth stage.

3-D CT EVALUATION OF CONDYLE HEAD POSITION, MANDIBULAR WIDTH, AND MANDIBULAR ANGLE AFTER MANDIBULAR SETBACK SURGERY (3-D CT를 이용한 악교정수술후의 하악 과두 위치와 하악폭경 및 하악각의 평가)

  • Kim, Jae-Won;Lee, Dong-Hyun;Lee, Su-Youn;Kim, Jae-Hyun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.229-239
    • /
    • 2009
  • The purpose of this study is to evaluate the change in condylar position, width, and angle before and after orthognathic surgery using 3-dimensional computed tomograph. Pre and posterative 3-D CT was taken on 38 patients and through axial, frontal, sagittal measurements and by 3-dimensional reconstruction, the changes in condylar postion, mandibular width and angle were analyzed and others such as the difference in gender, operation and fixation method, setback length and in relation with temporomandibular disorders were done together too. The results were as follows: The inward rotation of condyle in axial condylar angle, the forward movement of right condyle in sagittal anterior-posterior distance, the superior movement of both condyles in sagittal superior-inferior distance, the decrease in gonial angle, the increase in mandibular width, the decrease in distance between the axial coronoid process distance and the increase in the frontal intercondylar distance were statistically significant. There were no statistically significant changes in gender difference, however in the difference in operation method, change in the gonial angle was observed and there was more change in bilateral sagittal split osteotomy group compared to two-jaw surgery group. In the difference in fixation method, the decrease in axial coronoid process distance and the change in sagittal anterior-posterior distance were statistically significant. In the difference in setback, the increase in setback didn't relate directly with the increased change in condyle position. In the relation with temporomandibular disorder, changes in left axial condylar angle and axial coronoid process distance were statistically significant. Changes in condylar position could be observed after the orthognathic surgery but it doesn't seem to have much of a clinical importance. The orthognathic surgery is effective in decreasing the mandibular angle, and it is not related with the temporomandibular disorder.

Position Control of Sliding Mode Control Systems with Compensation of Estimated Coulomb friction (추정된 쿨롱 마찰을 보상한 슬라이딩 모드 제어 시스템의 위치제어)

  • 김한메;최정주;이영진;김종식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.35-42
    • /
    • 2004
  • The control systems with friction cause the steady state error and slow response, because friction is a sensitive to the change of system condition and has highly nonlinear characteristics. To overcome these problems and do precise position control for a ball-screw system, we use Coulomb friction estimator and the sliding mode control(SMC) to compensate its negative effect. The applied SMC for tracking position has a characteristics of robust stability and reducing chattering, and is derived from the Lyapunov stability theorem and reaching condition. Compensating the estimated friction torque to the bounded disturbance term of the SMC's equivalent control input, it has a tracking performance better than the PID from the experimental results.

Optical dielectric function of impurity doped Quantum dots in presence of noise

  • Ghosh, Anuja;Bera, Aindrila;Ghosh, Manas
    • Advances in nano research
    • /
    • v.5 no.1
    • /
    • pp.13-25
    • /
    • 2017
  • We examine the total optical dielectric function (TODF) of impurity doped GaAs quantum dot (QD) from the viewpoint of anisotropy, position-dependent effective mass (PDEM) and position dependent dielectric screening function (PDDSF), both in presence and absence of noise. The dopant impurity potential is Gaussian in nature and noise employed is Gaussian white noise that has been applied to the doped system via two different modes; additive and multiplicative. A change from fixed effective mass and fixed dielectric constant to those which depend on the dopant coordinate manifestly affects TODF. Presence of noise and also its mode of application bring about more rich subtlety in the observed TODF profiles. The findings indicate promising scope of harnessing the TODF of doped QD systems through expedient control of site of dopant incorporation and application of noise in desired mode.

Development of 3D Display System for Video-guide Operation

  • Honda, Toshio;Suzuki, Kou;Kuboshima, Yasuhito;Shiina, Tatsuo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1799-1802
    • /
    • 2007
  • In the constructed auto-stereoscopic display system for one observer. 1.stereoscopic images displayed on a special LCD are made on a large concave mirror. 2.The view-zone limiting aperture is set between the projection lens and the concave mirror. 3.The real image of the aperture is made at the observer's eye position by the concave mirror. 4.The observer's eye-position tracking of the view-zone is realized. 5.At same time, stereoscopic image changes automatically according to the eye position of the observer.

  • PDF