• Title/Summary/Keyword: Portable signal

Search Result 264, Processing Time 0.023 seconds

Analysis of Coupling Between Digital Noise and Portable Smart Terminal Antenna According to Antenna Types (휴대용 스마트 단말기 안테나 타입에 따른 디지털 노이즈와 안테나의 결합 분석)

  • Kim, Joonchul
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.873-877
    • /
    • 2019
  • In this paper, we analyze the degree of digital noise coupling for Inverted F Antenna (IFA) and Loop Antenna, which are representative types of portable terminal antenna, using characteristic mode. Firstly, the degree of coupling according to the direction of digital signal lines and characteristic mode current of the printed circuit board (PCB) including the antenna is compared and analyzed, and based on this result, the coupling between WiFi antenna and the front camera noise is analyzed. For analysis, the digital signal line and ground line of the FPCB of the camera module are modeled as a loop feeder that excites the characteristic mode of the PCB ground and the change of noise coupling according to the antenna types are analyzed.

Realization of temperature compensation algorithm on portable radiation detection device based on Cortex-A9 (Cortex-A9 기반 휴대용 방사선 검출장치에서의 온도보상 알고리즘 구현)

  • Nam, Hye-Jin;Lee, Jon-Hwey;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2729-2735
    • /
    • 2013
  • Safety and security system have been internationally enhanced in a field of shipping logistics. Accordingly, techniques for safety and security have been studied steadily. The need of portable radiation detection device is increasing by the search of the container is enhanced. In this paper, we propose to study on the application of the temperature compensation algorithm to the platform to improve the accuracy and the realization of portable radiation detection device based on Cortex-A9. Analog board deforms signal output from the sensor. And Cortex-A9 platform analyzes the signal received and displays the results. Additionally we use the temperature compensation algorithm and thereby we ca look the same results even if the temperature changes.

Development of Signal Processing System for Polysomnographic Diagnosis (수면 다원 진단을 위한 신호 처리시스템 개발)

  • 서진우;박해정;박광석;정도언
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.110-112
    • /
    • 2000
  • Recently, the interest and the importance of the signal monitoring and recording during sleep is increasing. Conventional paper based recording systems are being replaced by digital type and polysomnographic system. We developed special digital signal processor system for the polysomnographic recording. This system consists of digital signal processing part and PC interface part for user's convenience. This system includes two digital filters, one fur low pass filtering of high frequency noise and the other for notch filtering of 60Hz AC noise. This system can be used for the efficient and convenient measurement of polysomnographic signals and also can be developed for the portable use.

  • PDF

Portable urodynamics monitoring system based on ubiquitous technology (유비쿼터스 기반 휴대용 방광기능 검사 장치)

  • Kim, Keo-Sik;An, Yang-Su;Song, Chul-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.43-45
    • /
    • 2007
  • We developed a portable urodynamics monitoring system using personal digital assistance (PDA) and proposed a new method for measuring the abdominal pressure in non invasive mode using surface EMG signals. This system is consisted of a signal conditioning and control module and could measure the vesical, abdominal and detrusor pressure. The result showed a high correlation coefficient between the practical abdominal pressure, using a conventional rectal catheter and the estimated values, by our proposed algorithm (r=0.81). This system should prove a useful tool in the future evaluations of ambulatory urodynamics monitoring study.

  • PDF

Development of a Portable Cardiac Event Recorder (휴대용 심전도 이벤트 기록기 개발)

  • Chun, H.G.;Kim, H.C.;Lee, C.Y.;Kim, I.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.187-188
    • /
    • 1998
  • A low cost, low power, portable cardiac event recorder as a tether-free biological signal processor was developed. Dual channel ECG signals are sampled at 128Hz in 12 bits resolution. Sampled data are continuously recorded in a circular buffer. If event button is pressed, 2 minutes data before and after the event are recorded in 512 Kbyte SRAM. Total 11 events can be recorded. Data can be transferred to PC through RS-232 protocol. It operates for two months by a half AA size 3.6V Lithium battery. The system size is $55\times55\times13[mm^3]$.

  • PDF

Realization of alarm algorithm on portable radiation detection device based on Cortex-A9 (Cortex-A9 기반 휴대용 방사선 검출장치에서의 알람 알고리즘 구현)

  • Nam, Hye-Jin;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.387-390
    • /
    • 2014
  • In this paper, we propose to study on the application of the alarm algorithm to the platform of portable radiation detection device based on Coretex-A9 to ensure the safety of user. The analog board transforms sensor's signal and the platform based on Cortex-A9 outputs the results. The radiation detection's alarm is realized to LED and Buzzer to ensure safety of user.

  • PDF

Study on the Detection the Section with the Motion Artifacts of the PPG Signal (PPG 신호의 동잡음 구간 검출에 관한 연구)

  • Lee, Hanwook;Lee, Gunki
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • The biomedical information (heart rate, HRV, $SpO_2$ etc) from the Photoplethysmography (PPG) signal section can be estimated without the motion artifacts if the PPG signal section in the motion artifacts is detected accurately. But the PPG signal is easily exposed to the motion artifacts by the decrease of the medical instrument size and applying as portable or wearable. Besides, it is difficult to completely eliminate the motion artifacts from the PPG signal without distortion and ensure reliability as well. In this paper, the method was suggested to determine the motion artifacts or not on the PPG signal of the section divided into intervals of constant length. By comparing the spectrum of each section, it can be determined whether the motion artifacts are or not after obtaining the spectrum of each section by the Goertzel algorithm. Moreover, an amount of computation while maintaining a high detection rate can be reduced by using the Goertzel algorithm.

Electrocardiogram Signal Compression with Reconstruction via Radial Basis Function Interpolation Based on the Vertex

  • Ryu, Chunha;Kim, Tae-Hun;Kim, Jungjoon;Choi, Byung-Jae;Park, Kil-Houm
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.13 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Patients with heart disease need long-term monitoring of the electrocardiogram (ECG) signal using a portable electrocardiograph. This trend requires the miniaturization of data storage and faster transmission to medical doctors for diagnosis. The ECG signal needs to be utilized for efficient storage, processing and transmission, and its data must contain the important components for diagnosis, such as the P wave, QRS-complex, and T wave. In this study, we select the vertex which has a larger curvature value than the threshold value for compression. Then, we reconstruct the compressed signal using by radial basis function interpolation. This technique guarantees a lower percentage of root mean square difference with respect to the extracted sample points and preserves all the important features of the ECG signal. Its effectiveness has been demonstrated in the experiment using the Massachusetts Institute of Technology and Boston's Beth Israel Hospital arrhythmia database.

Remote Measurement for ECU Self Diagnostic Signal by RF Module (RF 모듈을 이용한 ECU 자기진단 신호의 원격 계측)

  • 정진호;이영춘;윤여흥;권대규;이우열;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.231-234
    • /
    • 2001
  • OBD-II regulations are already effective in many countries. The California Air Resources Board(CARB) first issued regulations in 1985 for the 1988 model year, known as OBD-I, and required the vehicle's engine management computer to warn the driver by means of a dash-mounted light if a malfunction occurred in either the oxygen sensor, the exhaust gas recirculation(EGR) valve or the evaporative emission system purge solenoid, and to store information on troubles that have no recurrent characteristics. This paper presents two methods of wireless monitoring OBD signal, which is one of the ECU output for self diagnostic measurement. RF module is used to monitor ECU's Self diagnostic signal remotely. Two kinds of measurement systems which are based on micro-controller(80C196KC) for portable detection and PC for sever are considered for receiving the RF signal. Therefore, possibility of real-time monitoring of ECU's self diagnostic signal remotely is verified on this paper.

  • PDF

Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves (발전용 밸브누설 음향 진단 및 감시시스템)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF