• Title/Summary/Keyword: Portable imaging

Search Result 76, Processing Time 0.031 seconds

Implementation and Evaluation of Optimal Dose Control for Portable Detectors with SiPM (SiPM을 통한 휴대용 검출기의 최적 선량 제어에 대한 구현 및 평가)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1139-1147
    • /
    • 2023
  • The purpose of this paper is to present and evaluate the performance of a method for controlling the dose for optimal image acquisition while minimizing patient exposure by applying a small-sized Photomultiplier(SiPM) sensor inside a portable detector. Portable detectors have the advantage of being able to quickly access the patient's location for rapid diagnosis, but this mobility comes with the challenge of dose control. This paper presents a method to identify the dose that can have the DQE and optimal image quality of the detector through image evaluation based on IEC62220-1-1, an international standard for X-ray imaging devices, and to identify the optimal dose by matching the ADU of the image and the output of the SiPM Sensor. The Skull AP image was acquired by implementing the detector manufacturer's reference dose. The optimal dose was 342.8 µGy, and the optimal controlled dose was 148.3 µGy, which is 57 % of the manufacturer's reference dose. The Chest AP image was 81.9 µGy and the optimal controlled dose was 27.9 µGy, which is a high dose reduction effect of 66 %. In addition, the two images were analyzed by five radiologists and found to have no clinically significant difference in anatomical delineation.

Analysis of source characteristics for high-resolution seismic surveys on a tidal flat (조간대 지역에서의 고해상 탄성파 탐사를 위한 파원 특성 분석)

  • Hong, Jong Guk;Kim, Gi Yeong;Kim, Han Jun
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.2
    • /
    • pp.100-110
    • /
    • 1999
  • In order to find a good seismic source for high-resolution reflection surveys on a tidal flat, characteristic features of several sources were examined through test recording by the walkaway configuration. The sources comprise portable vibrator, 1.2 kg monkey spanner, 4.7 kg sledge hammer, and weight drops with a 30 kg and a 100 kg iron ball, respectively. We analyzed raw and filtered seismic data for the resolution of individual events, then compared various seismic sources to define suitable one for the high-resolution survey in terms of energy level and frequency contents. The study reveals that the portable vibrator is the most suitable source for the detection of and imaging geologic structures less than 20-30 m deep in a tidal flat. We ascribe this to the wide frequency band and high-frequency contents of the portable vibrator. In contrast, the hammer may be an alternative where the target depth increases up to 100 m.

  • PDF

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

Using Hyperspectral Fluorescence Spectra of Deli Commodities to Select Wavelengths for Surveying Deli Food Contact Surfaces

  • Lefcourt, Alan M.;Beck, Elizabeth A.;Lo, Y. Martin;Kim, Moon S.
    • Journal of Biosystems Engineering
    • /
    • v.40 no.2
    • /
    • pp.145-152
    • /
    • 2015
  • Purpose: The inability to adequately judge the efficacy of cleaning and sanitation procedures in deli departments is a recognized food safety concern. In a prior study, our research group demonstrated that visual inspection of cleaned produce processing surfaces could be enhanced through the use of a portable fluorescence imaging device that detected residual produce residues. Methods: To explore the feasibility of using fluorescence imaging to similarly detect residual deli residues, spectra of American, Cheddar, Provolone, and Swiss cheeses and of processed chicken, ham, roast beef, and turkey were acquired using a laboratory hyperspectral imaging system. Circular punches of these commodities were placed onto stainless steel and high density polyethylene coupons for imaging. The coupon materials were selected to represent common surfaces found in deli departments. Results: Analysis of hyperspectral fluorescence images showed that cheeses exhibited peaks in the blue-green region and at around 675 nm. Meats exhibited peaks in the blue-green region with one of four ham and one of four chicken brands exhibiting peaks at around 675 nm, presumably due to use of plant-derived additives. When commodities were intermittently imaged over two weeks, locations of spectral peaks were preserved while intensity of peaks at shorter wavelengths increased with time. Conclusion: These results demonstrate that fluorescence imaging techniques have the potential to enhance surface hygiene inspection in deli departments and, given the immediate availability of imaging results, to help optimize routine cleaning procedures.

Compact See-though Near to Eye Display with Diffractive Optical Elements

  • Levola, Tapani
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1749-1752
    • /
    • 2007
  • The Near to Eye Display (NED) solves the problem of having a display larger than a small portable device. The virtual image of the NED is created using a microdisplay and imaging optics. It is important that the optics does not interfere with the human visual system and that the device is light, compact and easy to wear. In this paper the principles of a biocular NED, which is based on a novel diffractive Exit Pupil Expander (EPE), are presented. The optical system is compact and intrinsically free from distortions and misalignments.

  • PDF

Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device (이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정)

  • Hong, Sun-Suk;Kim, Deuk-Yong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

Digital Camera Characterization Method under Multiple Illuminants (다중 광원에서의 디지털 카메라 특성화 방법)

  • Yoon, Chang-Rak;Cho, Maeng-Sub
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.10b
    • /
    • pp.871-874
    • /
    • 2000
  • 디지털 카메라(Digital Camera)와 같은 휴대형 영상 입력 장치(Portable Image Input Device)는 스캐너 (Scanner)와 달리 3 차원의 피사체(Object)를 디지털 영상으로 생성할 수 있고 다양한 조명 환경(Illuminant)에서 사용할 수 있다는 이유로 많은 응용 분야에서 활발하게 사용되고 있다. 그러나, 정확한 색 재현(Color Reproduction)을 위한 기존의 디지털 카메라 특성화 방법(Digital Camera Characterization Method)은 생성된 영상의 조명 정보를 고려하지 않은 상태에서 색 변환 행렬을 생성하므로 다양한 조명 환경 변화에 대해 적응적으로 대처하지 못하는 단점이 있다. 본 논문에서는 디지털 카메라가 생성하는 영상의 rgb 색도를 이용하여 색도 평면에 색도 다각형(Chromaticity Polygon)을 구성하고 각 색도 다각형들간의 포함 관계에 따라 조명 정보를 평가함으로써 조명색(Illuminant Color)의 변화에 따른 인간 시각 시스템(Human Visual System)의 색 불변성(Color Constancy)을 재현할 수 있는 디지털 카메라 특성화 방법을 제안한다.

  • PDF

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Use of Chlorophyll a Fluorescence Imaging for Photochemical Stress Assessment in Maize (Zea mays L.) Leaf under Hot Air Condition

  • Park, Jong Yong;Yoo, Sung Young;Kang, Hong Gyu;Kim, Tae Wan
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.61 no.4
    • /
    • pp.270-276
    • /
    • 2016
  • The objective of this study was to find a rapid determination of the hot air stress in maize (Zea mays L.) leaves using a portable chlorophyll fluorescence imaging instrument. To assess the photosynthetic activity of maize leaves, an imaging analysis of the photochemical responses of maize was performed with chlorophyll fluorescence camera. The observed chlorophyll imaging photos were numerically transformed to the photochemical parameters on the basis of chlorophyll a fluorescence. Chlorophyll a fluorescence imaging (CFI) method showed that a rapid decrease in maximum fluorescence intensity ($F_m$) of leaf occurred under hot air stress. Although no change was observed in the maximum quantum yield ($F_v/F_m$) of the hot air stressed maize leaves, the other photochemical parameters such as maximum fluorescence intensity ($F_m$) and Maximum fluorescence value ($F_p$) were relatively lowered after hot air stress. In hot air stressed maize leaves, an increase was observed in the nonphotoquenching (NPQ) and decrease in the effective quantum yield of photochemical energy conversion in photosystem II (${\Phi}PSII$). Thus, NPQ and ${\Phi}PSII$ were available to be determined non-destructively in maize leaves under hot air stress. Our results clearly indicated that the hot air could be a source of stress in maize leaves. Thus, the CFI analysis along with its related parameters can be used as a rapid indicating technique for the determining hot air stress in plants.

Adaptive quantization for effective data-rate reduction in ultrafast ultrasound imaging (초고속 초음파 영상의 효과적인 데이터율 저감을 위한 적응 양자화)

  • Doyoung Jang;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.422-428
    • /
    • 2023
  • Ultrafast ultrasound imaging has been applied to various imaging approaches, including shear wave elastography, ultrafast Doppler, and super-resolution imaging. However, these methods are still challenging in real-time implementation for three Dimension (3D) or portable applications because of their massive data rate required. In this paper, we proposed an adaptive quantization method that effectively reduces the data rate of large Radio Frequency (RF) data. In soft tissue, ultrasound backscatter signals require a high dynamic range, and thus typical quantization used in the current systems uses the quantization level of 10 bits to 14 bits. To alleviate the quantization level to expand the application of ultrafast ultrasound imaging, this study proposed a depth-sectional quantization approach that reduces the quantization errors. For quantitative evaluation, Field II simulations, phantom experiments, and in vivo imaging were conducted and CNR, spatial resolution, and SSIM values were compared with the proposed method and fixed quantization method. We demonstrated that our proposed method is capable of effectively reducing the quantization level down to 3-bit while minimizing the image quality degradation.