• Title/Summary/Keyword: Portable equipment

Search Result 235, Processing Time 0.026 seconds

The Propriety of Portable Digital X-RAY Equipment for Emergency Medical Services (델파이 기법을 이용한 응급의료에서의 휴대용 디지털 X-ray 발생장치의 적절성)

  • Cho, Dong-Heon;Gu, Kyung-Wan;Yang, Hae-Sool;Jo, Jean-Man;Han, Man-Seok;Lee, Mi-Ok
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • The purpose of this study is to analyze the propriety of portable digital X-ray Equipment for Emergency Medical Services in Daejon Emergency Medical Center in Korea. The major instruments of this study were Korean Self-Analysis Opinionnaire, Questionnaire contains 35 items which measure emergency medical personal opnions. To take the analysis of data, the total of 92 persons were investigated in Medical Information Center in Daejon Metropolitan City from 2005. 20. April to 2004. 25. May. The data were analyzed by the path analysis SPSS program. First, portable X-RAY equipment is needed to apply it to emergency. Second, it should have small and light structure compared with old equipments and have high voltage generator unit for X-RAY using inverter. Third, it should be able to send the shot data that is digital detector type without film to doctors in emergency center.

  • PDF

A study on radiation safety education, knowledge, and practice in using portable intraoral X-ray equipment of dental hygienist's (치과위생사의 이동형 구내방사선 촬영에 관한 방사선 방어 교육, 지식, 수행에 관한 연구)

  • Ryu, Jeong-Min;Kang, Bo-Sun;Kim, Seol-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.6
    • /
    • pp.1053-1065
    • /
    • 2017
  • Objectives: The purpose of this study is to evaluate radiation safety education, knowledge and practice of dental hygienists in using handheld portable intraoral X-ray equipment and to suggest the need for radiation safety education in using handheld portable intraoral X-ray equipment. Methods: We surveyed 223 dental hygienists from July, 2017 to August in the dental clinics of Daejeon, Seoul and Gyeonggi area. Results: Radiation safety educational experience was higher in a year's career (72.9%), than 3 years experience (32.5%) (p<0.05). 82.7% of dental clinic workers took university education for radiation safety education while 55.6% of dental hospital workers took company training (p<0.05). More than 70% of the subjects did not have experience of radiation safety education about using portable intraoral X-ray. Radiation safety knowledge was highest in a year's career (p<0.05). The cumulative dose, radiation sensitivity, and lead defense knowledge were high in all subjects, but knowledge related to scattering radiation and scattering radiation sources was low. Practice of portable intraoral X-ray safety was significantly lower than knowledge. Conclusions: Knowledge of portable intraoral radiography safety is available, but performance is poor. Even with the small amount of radiation exposure, the risk is perceivable. There is a need to actively utilize the provided radiation protection products. In order to do this, efforts should be made to improve knowledge and performance of radiation safety through not only college education but also postemployment training.

Implementation of PXIe platform based portable Automatic Test Equipment to improve reliability

  • Gwon, Hyeok-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.9-16
    • /
    • 2017
  • In this paper, we propose a development method of portable Automatic Test Equipment based on PXIe platform. Legacy VME form factor structured test equipment has limited reuse and expansion of modules due to unapplied bus specification. In particular, these limitations can cause development periods and costs to increase, and the reliability of environmental conditions is lacking due to non-standard modules. The test equipment of the proposed PXIe platform can use diverse COTS modules to shorten the development period and minimize the instability between developments. The PXIe development module works with standard Xilinx FPGAs, PXIe Windows device drivers, and applications on standard PXIe buses. The use of standard bus and COTS modules increases scalability and reusability, enabling rapid development and excellent maintenance. Through the test, we show the proposed test equipments can be implemented efficiently between the development processes and proved their reliability through function tests and environmental tests.

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

A study on Automatic field Test Equipment with improved maintenance and environmental reliability

  • Lee, Seok-Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.3
    • /
    • pp.9-16
    • /
    • 2018
  • In this paper, I purpose one of the development methods for portable Automatic field Test Equipment(ATE) with VME form factor. Almost portable ATE have not used to standards form factor and they are connected by mechanical non-rigid general connectors and wire harnesses among the components. Furthermore, it is hard to reuse developed board. So, it decreases to reusability of developed board and it is hard to maintenance of ATE. Even those things have weakness for vibration and drop test especially in portable ATE. The XK9A1 ATE using VME form factor has environmental reliability through vibration, drop, temperature test. It consists of 5 developed board called the control board, the wire & wireless communication board, the power supply board, the load board and the mother board. It is connected by two wire harnesses between mother board and extern circular connectors. The control board send the data and address to other board though each 16-bit data and 20-bit address line. You can develop the function board what you want to using those data & address line when it comes to needing other function board.

Time uncertainty analysis method for level 2 human reliability analysis of severe accident management strategies

  • Suh, Young A;Kim, Jaewhan;Park, Soo Yong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.484-497
    • /
    • 2021
  • This paper proposes an extended time uncertainty analysis approach in Level 2 human reliability analysis (HRA) considering severe accident management (SAM) strategies. The method is a time-based model that classifies two time distribution functions-time required and time available-to calculate human failure probabilities from delayed action when implementing SAM strategies. The time required function can be obtained by the combination of four time factors: 1) time for diagnosis and decision by the technical support center (TSC) for a given strategy, 2) time for strategy implementation mainly by the local emergency response organization (ERO), 3) time to verify the effectiveness of the strategy and 4) time for portable equipment transport and installation. This function can vary depending on the given scenario and includes a summation of lognormal distributions and a choice regarding shifting the distribution. The time available function can be obtained via thermal-hydraulic code simulation (MAAP 5.03). The proposed approach was applied to assess SAM strategies that use portable equipment and safety depressurization system valves in a total loss of component cooling water event that could cause reactor vessel failure. The results from the proposed method are more realistic (i.e., not conservative) than other existing methods in evaluating SAM strategies involving the use of portable equipment.

Economical Gas Chamber for In-situ Gas Measurement and Analysis of Gas Response Characteristics according to Sensor Voltage (인시투 가스 측정이 가능한 경제적 가스 챔버 구현 및 센서 전압에 따른 가스 응답 특성 분석)

  • Choi, Yun-Suk;Lee, In Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2019
  • Breath analysis using a portable device is better than the classical breath analysis system in terms of installation and operation. There is an increasing need to develop cost-effective equipment for testing gas sensors from the viewpoint of functionalities that can be applied applicable to portable devices. In the present study, an economical gas chamber for in-situ gas measurement is implemented with a single gas chamber without using expensive gas storage and control equipment; the gas response characteristics are analyzed using the above-described chamber. The main features of the implemented gas chamber are simple injection procedure, improved gas diffusion, easy measurement and cleaning, support for low-power mode measurement function for portable devices, and open source platform. Moreover, an analysis of gas response characteristics based on changes in sensor voltage show that the sensitivity and 90% response time are affected by the sensor voltage. Furthermore, the sensitivity graph has an inflection point in a specific range. The gas sensor applied in this study showed fast response speed and high sensitivity for sensor voltages of 3.0-3.5 V, regardless of the concentration of acetone gas, the target gas used in this study.

A PORTABLE TORQUE AND POWER MEASUREMENT SYSTEM FOR SMALL FARM EQUIPMENT BASED ON AN INSTRUMENTED PULLEY

  • Pasikatan, M.C.;Quick, G.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.298-306
    • /
    • 1993
  • A portable torque and power measurement system for small farm equipment based on instrumented pulley was developed. The prototype pulley was machined from mild steel, with spokes serving as strain beams. Strain gages mounted to the spokes sense the bending strain due to the torque and convert this into millivolt output. Calibration results showed the torque-millivolt relationship was linear, while hysterisis and error were less than 1% fs. For power measurements, an additional tachmeter with dcvoltage output is necessary. With the tachometer , error in power measurement was +-1.03W or 0.2% fs. Field tests showed that for ease of installation, no machine alteration needed and safety, this system had advantage over other methods for small farm equipment.

  • PDF

Hazard Identification and Risk Assessment for the Use of Passenger Portable Electronic Devices (승객 휴대 전자기기 사용에 대한 위해요인 식별 및 리스크 평가)

  • Lim, In-Kyu;Kim, Mu-Geun;Kang, Ja-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.288-294
    • /
    • 2018
  • The entertainment system of the aircraft has changed its paradigm in the form of using passenger electronic devices instead of using a fixed monitor. This has simplified the on-board equipment while the risk of safety has increased with the electric charging of portable electronic devices. Unlike personal portable electronic devices that do not have a transmission function, the use of Wi-Fi enabled electronic devices(T-PED) is allowed and the battery is required to be charged in the cabin. In this study, we used the NASA Aviation Safety Reporting System to investigate the effects of changes in wireless environment and entertainment service. Based on this, we analyzed the risks of personal electronic devices by sharing event occurrence cases caused by in-flight electronic equipment or passenger portable electronic devices(especially smart phones) from the viewpoint of aircraft safety management. This analysis includes identification of potential hazards and risk assessment, and finally the strategies for risk mitigation for safe use of portable electronic devices are suggested.

A Portable ECG System Coupled with a Smartphone (스마트폰과 연동한 휴대용 심전도계)

  • Kim, Kiwan;An, Jonghyun;Park, Kwangmin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.1
    • /
    • pp.7-11
    • /
    • 2021
  • The electrocardiogram(ECG) and heart rates are essential for diagnosing heart disease. However, conventional portable ECG devices are possible to only measure heart rates or have limitations in how and where they are measured. In this paper, a portable ECG system in which ECG waveforms and heart rates are displayed on smartphone screens is developed. A smartphone is used as display equipment instead of a computer screen for continuous monitoring. The developed ECG system filters and amplifies detected analog ECG signals. Next, it converts the amplified analog ECG signals into digital signals, then transmits to the smartphone via Bluetooth communication. This ECG system can display and store biomedical signals on a smartphone through the application. As a result, the waveform and heart rates of the developed portable ECG system has been confirmed to be similar to those of existing medical devices.