• Title/Summary/Keyword: Portable Patterns

Search Result 65, Processing Time 0.032 seconds

A study on the radiation pattern analysis of the monopole antenna mounted on a portable phone (휴대전화기에 장착된 모노폴안테나의 방사패턴 해석에 관한 연구)

  • 정옥현;문영찬;윤상원;장익수
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.12
    • /
    • pp.16-24
    • /
    • 1996
  • In this paper, the radiation pattern of the monopole antenna mounted on the portable phone is analyzed. The analyzed model consists of a rectangular conductor box and a monopole antenna. Even though the radiation pattern of the monopole has been well known, the monopole antenna mounted on the portable phone has not been fully studied. Because of the conductor box, portable phone acts as an unbalanced dipole antenna whoe radiation patterns deviate fro those of th econventional isolated monopole antenna. Therefore, the analysis of the radiation patterns of unbalanced dopole antenna is necessary. Using the moment method, its radiation patterns are analyzed and the numerical results are verified through the measurements. In addition, the radiation patterns depending on various length of the conductor box and the monopole antenna are also presented and the dimension of the portable phone which gives excellent radiation characteristics are derived from the analyzed results.

  • PDF

A portable multichannel FES system for control of paralyzed extremities (마비된 말단근육의 제어를 위한 휴대용 다중 채널의 기능적 전기자극(FES) 장치)

  • 류영재;박봉기;김영민;임영철;김하경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.90-94
    • /
    • 1992
  • A portable multichannel functional electrical stimulation(FES) system for the fine control of the paralyzed extremities in spinal cord injury patients is described. This system is composed of a stimulation data creating system, a serial communication device, a 16-bit microprocessor, D/A converter of 32 channels and a display device. Stimulation patterns are created from analytical results of integrated EMGs during motion in normal subjects and are stored in the stimulation data creating system as data files. And then the stimulation patterns are sent to the memory in the portable multichannel FES system through serial communication interfacing device. Sophisticated fine control of paralyzed extrimities was realized by transmitting multichannel stimulation patterns to percutaneous intramuscular electrodes, which stimulate the motor function of paralyzed muscle simultaneously. Advantages of this system are as follws: 1) It is possible to modify stimulation patterns in accordance with the patient's situation. 2) This system is small and light.

  • PDF

Analysis of Power Consumption Patterns for Commercial Portable Multimedia Players (상용 휴대형 멀티미디어 재생기 전력소모 패턴 분석)

  • Nam, Young-Jin;Yang, Eun-Ju;Lee, Jong-Yuol;Kim, Seong-Ryul;Seo, Dae-Wha
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.3
    • /
    • pp.95-103
    • /
    • 2007
  • Portable multimedia Player (PMP) devices have been gaining in its popularity with the emerging digital convergence of data, video, audio, etc. Since the PMP devices are typically equipped with DSP, a bigger LCD screen, and a hard disk, efficient power management has become more crucial than the other portable devices. This paper builds up a hardware/software-based power measurement system based on data acquisition devices. Subsequently, it measures and analyzes the power consumed in commercial PMP devices under different types of events: the system boot & shutdown, video playback, and the use of different video-coding types. Finally, our analysis of the measured power consumption patterns reveals useful information for the design of low-power PMP devices.

  • PDF

Development of Portable Electronic Tongue using Fuzzy clustering algorithm (Fuzzy Clustering 알고리즘을 이용한 휴대용 전자 혀 개발)

  • Kim, Joeng-Do;Ham, Yu-Kyung;Jung, Woo-Suk;Jung, Young-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.602-604
    • /
    • 2004
  • A portable electronic tongue(E-Tongue) system using an array of ion-selective electrode(ISE) and personal digital assistants(PDA) for recognizing and analyzing food and drink have been designed. By the employment of PDA, the complex algorithm such as fuzzy c-means algorithm(FCMA) could be used in E-Tongue, FCMA could iteratively solve the cluster centers of pre-determined standard patterns. And the membership between the standard patterns and unknown pattern could be analyzed easily by the present E-Tongue combined with PDA.

  • PDF

Design of a Portable Electronic Tongue System using Fuzzy C-Means Algorithm (Fuzzy C-Means Algorithm을 이용한 휴대용 전자혀 시스템 설계)

  • Kim, Jeong-Do;Kim, Dong-Jin;Ham, Yu-Kyung;Jung, Young-Chang;Yoon, Chul-Oh
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.446-453
    • /
    • 2004
  • A portable electronic tongue (E-Tongue) system using an array of ion-selective electrode (ISE) and personal digital assistants (PDA) for recognizing and analyzing food and drink have been designed. By the employment of PDA, the complex algorithm such as fuzzy c-means algorithm (FCMA) could be used in E-Tongue, PUMA could iteratively solve the cluster centers of pre-determined standard patterns. And the membership between the standard patterns and unknown pattern could be analyzed easily by the present E-Tongue combined with PDA.

Development of a Portable Electronic Nose System (I) - System Development - (휴대용 전자코 시스템 개발 (I) - 시스템 개발 -)

  • Lee, Jeong-Woo;Kim, Seong-Min
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.333-339
    • /
    • 2008
  • The purpose of this study was to develop a portable electronic nose system to measure volatile components of agricultural and food products. Also, a graphical operating software to control the electronic nose system and to acquire signals through the Internet was developed. An array of five commercial metal oxide gas sensors was used to detect various volatile gas components of target samples. Transient and steady state signals were analyzed to extract variables related to sample states, To find optimal operating conditions of the system, several experiments were performed with different gas chambers, vacuum pumps, gas sampling temperatures, and sample container sizes. The patterns of gas sensor signals were analysed to find effects of the various conditions.

J-Tree: An Efficient Index using User Searching Patterns for Large Scale Data (J-tree : 사용자의 검색패턴을 이용한 대용량 데이타를 위한 효율적인 색인)

  • Jang, Su-Min;Seo, Kwang-Seok;Yoo, Jae-Soo
    • Journal of KIISE:Databases
    • /
    • v.36 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • In recent years, with the development of portable terminals, various searching services on large data have been provided in portable terminals. In order to search large data, most applications for information retrieval use indexes such as B-trees or R-trees. However, only a small portion of the data set is accessed by users, and the access frequencies of each data are not uniform. The existing indexes such as B-trees or R-trees do not consider the properties of the skewed access patterns. And a cache stores the frequently accessed data for fast access in memory. But the size of memory used in the cache is restricted. In this paper, we propose a new index based on disk, called J-tree, which considers user's search patterns. The proposed index is a balanced tree which guarantees uniform searching time on all data. It also supports fast searching time on the frequently accessed data. Our experiments show the effectiveness of our proposed index under various settings.

Portable Low-Cost MRI System Based on Permanent Magnets/Magnet Arrays

  • Huang, Shaoying;Ren, Zhi Hua;Obruchkov, Sergei;Gong, JIa;Dykstra, Robin;Yu, Wenwei
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.179-201
    • /
    • 2019
  • Portable low-cost magnetic resonance imaging (MRI) systems have the potential to enable "point-of-care" and timely MRI diagnosis, and to make this imaging modality available to routine scans and to people in underdeveloped countries and areas. With simplicity, no maintenance, no power consumption, and low cost, permanent magnets/magnet arrays/magnet assemblies are attractive to be used as a source of static magnetic field to realize the portability and to lower the cost for an MRI scanner. However, when taking the canonical Fourier imaging approach and using linear gradient fields, homogeneous fields are required in a scanner, resulting in the facts that either a bulky magnet/magnet array is needed, or the imaging volume is too small to image an organ if the magnet/magnet array is scaled down to a portable size. Recently, with the progress on image reconstruction based on non-linear gradient field, static field patterns without spatial linearity can be used as spatial encoding magnetic fields (SEMs) to encode MRI signals for imaging. As a result, the requirements for the homogeneity of the static field can be relaxed, which allows permanent magnets/magnet arrays with reduced sizes, reduced weight to image a bigger volume covering organs such as a head. It offers opportunities of constructing a truly portable low-cost MRI scanner. For this exciting potential application, permanent magnets/magnet arrays have attracted increased attention recently. A magnet/magnet array is strongly associated with the imaging volume of an MRI scanner, image reconstruction methods, and RF excitation and RF coils, etc. through field patterns and field homogeneity. This paper offers a review of permanent magnets and magnet arrays of different kinds, especially those that can be used for spatial encoding towards the development of a portable and low-cost MRI system. It is aimed to familiarize the readers with relevant knowledge, literature, and the latest updates of the development on permanent magnets and magnet arrays for MRI. Perspectives on and challenges of using a permanent magnet/magnet array to supply a patterned static magnetic field, which does not have spatial linearity nor high field homogeneity, for image reconstruction in a portable setup are discussed.

A Study on Interaction between Multimodal Feedback Setting and Portable Patterns through Behavior Study of Mobile Phone User in Mobile Environment (모바일 환경 내 휴대폰 사용자 행동연구를 통한 다중양식 피드백 설정과 휴대패턴의 상호영향 연구)

  • Baek, Young-Mi;Myung, Ro-Hae;Yim, Jin-Ho
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.579-586
    • /
    • 2006
  • 모바일 환경에서 휴대폰을 사용하다 보면 무의식적으로 전화를 받지 못하는(Missing call) 상황이 빈번하게 일어난다. 휴대폰에서는 기본적으로 시각 청각 촉각의 다중양식 피드백(Multimodal feedback)을 제공하고 있음에도 불구하고, 이렇게 Missing call 이 발생하는 현상에는 여러 가지 다양한 원인이 존재할 것이다. 본 연구에서는 이러한 원인을 찾기 위해 모바일 환경 내 휴대폰 사용자 행동연구를 실시하여 일반적인 휴대패턴을 분석하고, Missing call과 관련하여 주로 설정하는 수신모드와 휴대패턴의 상호영향을 연구하고자 하였다. 본 연구결과, 모바일 환경에서 휴대폰 수신 탐지능력에는 인지심리학적(감각과 주의관련), 환경적, 행동학적 요인이 영향을 미칠 수 있는 것으로 나타났다. 또한 모바일 환경에서 주로 사용하는 수신모드인 진동모드 설정시, 휴대폰 사용자가 속한 환경에 다른 요인들이 복합적으로 존재할 경우 휴대폰 수신에 대한 탐지만족도가 감소함을 확인할 수 있었다.

  • PDF

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.3
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.