Research of Resolution enhancement from portable radiation detection platform based on Cortex-A9 (Cortex-A9 기반 휴대용 방사선 검출장치에서의 분해능 향상을 위한 연구)

  • Kwon, Tae-Kyung;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.373-376
    • /
    • 2014
  • Shipping and logistics safety, security system is strengthening worldwide, the development of shipping and logistics safety security core technology for national security logistics system construction has been carried out. Interest in portable radiation detection device capable detecting gamma rays nuclides is increasing. In this paper, I would like to propose the study of resolution enhancement for accurate analysis of nuclides in the platform of the radiation detector portable with Cortex-A9.

  • PDF

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection (안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험)

  • Kwak, Sung-Woo;Ahn, Gil Hoon;Park, Iljin;Ham, Young Soo;Dreyer, Jonathan
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.

Effects of A-solution on Halitosis and Oral Status in Preoperative NPO Patients (A-solution을 이용한 구강 가글링이 수술 전 금식 환자의 구취와 구강 상태에 미치는 효과)

  • Song, Ji-Ah;Hur, Myung-Haeng
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.3
    • /
    • pp.405-413
    • /
    • 2012
  • Purpose: The aim of this study was to explore the effects of A-solution on halitosis and oral status in preoperative NPO patients. Methods: A nonequivalent control group, non-synchronized pretest-posttest design was used in this study. The participants in this study were 66 patients who were admitted for gynecologic surgery. The experimental treatment was to give oral gargling with A-solution, blended essential oils and diluted with distilled water. To identify the experimental treatment effects, halitosis, salivary pH, and oral status were measured by a portable halitosis detector, visual analogue scale, Bromo Thymol Blue (BTB), Bromo Cresol Purple (BCP) test paper and oral assessment guide. Data were analyzed using $X^2$-test, t-test with PASW 18.0 version. Results: Participants were homogeneous before experimental treatment. Objective halitosis in the experimental group, measured by a portable halitosis detector (t=-8.34, p<.001) was significantly lower than the control group. Subjective halitosis was significantly lower in the experimental group (t=-9.29, p<.001). Salivary pH was significantly different between two groups (t=8.81, p<.001). Oral status was significantly better in the experimental group (t=-13.31, p<.001). Conclusion: These findings indicate that oral gargling using A-solution is effective in reducing patient halitosis, and improving oral status.

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

Bacteriological Research for the Contamination of Digital Portable Radiography (디지털 이동방사선검사에서의 세균 오염도)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.

Laboratory Evaluation of the Accuracy, Precision, and Inter-instrumental Variance of a Portable Photoionization Detector (휴대용 광이온화 검출기의 정확도, 정밀도 및 기기간 차이에 대한 실험실 평가)

  • Choi, Dongmin;Choi, Youngeun;Yoon, Chungsik;Rhie, Kwangwon;Lee, Yunkeun;Lee, Ikmo;Park, Jeongim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.200-208
    • /
    • 2012
  • Objectives: This study investigated the performance of three separate units of a portable photoionization detector (PID, ppb-RAE 3000) for measuring volatile organic compounds (VOCs) in a laboratory. Methods: A laboratory evaluation of the accuracy, precision, and inter-instrumental variance of three separate units of a portable PID (ppb-RAE 3000) was performed. The evaluation was based on the preparation of a test air sample of known toluene or ethylacetate concentration in a Tedlar$^{(R)}$ bag. The test air sample was monitored and data were logged consecutively by the three PIDs. A certified gas of 50 ppm toluene was also monitored during the test to ensure the reliability of the generated test air sample. Four different concentrations ranging from 0.1 to 2 TLV were used and a series of five measurements for each concentration level was performed. The accuracy was evaluated using National Institute for Occupational Safety and Health (NIOSH) criteria. Results: The results from the oldest ppb-RAE3000 unit among the three test units generally fell outside the NIOSH recommended accuracy criteria of ${\pm}25%$, whereas the other two units produced results which were acceptable at, or greater than, 25 ppm of toluene, or 0.5 TLV. These units also met the NIOSH criteria for some ethylacetate measurements but the results were not consistent. Conclusions: Considering the inconsistent performance of these ppb-RAE 3000 units, this device may not be appropriate for use as an alternative to the standard measurement methods. However, it can serve good survey instruments to identify exposure sources or concentration profiles. For all applications, the ppb-RAE 3000 should be used with frequent calibration checks, additional validation using a reference material, and careful maintenance.

The Propriety of Portable Digital X-RAY Equipment for Emergency Medical Services (델파이 기법을 이용한 응급의료에서의 휴대용 디지털 X-ray 발생장치의 적절성)

  • Cho, Dong-Heon;Gu, Kyung-Wan;Yang, Hae-Sool;Jo, Jean-Man;Han, Man-Seok;Lee, Mi-Ok
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • The purpose of this study is to analyze the propriety of portable digital X-ray Equipment for Emergency Medical Services in Daejon Emergency Medical Center in Korea. The major instruments of this study were Korean Self-Analysis Opinionnaire, Questionnaire contains 35 items which measure emergency medical personal opnions. To take the analysis of data, the total of 92 persons were investigated in Medical Information Center in Daejon Metropolitan City from 2005. 20. April to 2004. 25. May. The data were analyzed by the path analysis SPSS program. First, portable X-RAY equipment is needed to apply it to emergency. Second, it should have small and light structure compared with old equipments and have high voltage generator unit for X-RAY using inverter. Third, it should be able to send the shot data that is digital detector type without film to doctors in emergency center.

  • PDF

Determination of Human Skin Moisture in the Near-Infrared Region from 1100 to 2200 nm by Portable NIR System (1100∼2200 nm 파장 영역의 휴대용 근적외선 분광분석기를 이용한 사람피부의 수분측정)

  • 안지원;서은정;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.3
    • /
    • pp.148-153
    • /
    • 2003
  • Skin moisture is an important factor in skin health. Measurement of moisture content can provide diagnostic information on the condition of skin. In this study, a portable near-infrared (NIR) system was newly integrated with a photo diode array detector that has no moving parts, and this system has been successfully applied for the evaluation of human skin moisture. Diffuse reflectance spectra were collected and transformed to absorbance using 1 nm step size over the wavelength range of 1100 nm to 2200 nm. Partial least squares regression (PLSR) was applied to develop a calibration model. For practical use for the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo using the portable NIR system on the basis of the relative water content values of stratum corneum from the conventional capacitance method. The PLS model showed a good correlation. The calibration with the use of PLS model predicted human moisture with a standard error of prediction (SEP) of 3.5 at 1120∼1730 nm range. This study showed the possibility of skin moisture measurement using portable NIR system.

Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.

An implementation of portable gamma ray detection platform using Cortex-A8 (Cortex-A8을 이용한 휴대용 감마선 검출 플랫폼 구현)

  • Seo, Jae-Gil;Lee, Yoon-Ho;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.1028-1033
    • /
    • 2013
  • As safety and security systems of shipping logistics are reinforced all over the world, ubiquitous technology-based core technology for safety and security is developing to build the system of logistics security. It is feared that the logistics security system of Korea has a possibility to technically depend on developed countries in the futures. Because the essential skills and equipment to retain security of logistics are not developed. It is urgent to introduce a logistics security system that fully integrates the entire logistics segment in the future. Thus, the necessity of developing the portable radiation detector which can detect gamma-ray nuclide is increasing for reinforcing safety and security systems. In this paper, a research suggests the implementation of portable radiation detector platform using Cortex-A8.