• 제목/요약/키워드: Porous Sheet

검색결과 68건 처리시간 0.033초

흑연분말을 이용한 다공성 니켈지지체의 제조에 관한 연구 (A Study on the Fabrication of Porous Nickel Substrates Using Graphite Powder)

  • 박성용;백지흠;조원일;조병원;윤경석
    • 한국표면공학회지
    • /
    • 제28권5호
    • /
    • pp.276-288
    • /
    • 1995
  • A nickel mesh and an expanded nickel sheet were used as a current collector for supporting active materials of cathode in rechargeable batteries, while a porous nickel substrate was extensively studied because of its 3-dimensional structure which has high capabilities for active materials and current collection. Optimum coating conditions were studied by SEM and two step d. c. constant current electrolysis for the graphite coating and electro-plated nickel on an urethane substance which was highly porous and 3-dimensional structure. The density and the porosity of nickel support obtained by using two step current density and 80 ppi urethane substance were 0.38∼0.40 g /㎤ and 94∼96%, respectively. It was possible to fabricate a highly porous and good packable nickel substrate using two step current density and surfactants at sulfamic acid nickel plating bath.

  • PDF

일측성 구순열비변형에서 다공성 폴리에틸렌 판을 이용한 상악골이상구증대술 (Augmentation of Pyriform Margin Using Porous High-Density Polyethylene Sheet In Unilateral Cleft Lip Nasal Deformity)

  • 한기환;김진한;최태현;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.431-438
    • /
    • 2008
  • Purpose: The common deformity after the correction of unilateral cleft lip nasal deformity is nasal asymmetry, and it is caused by the hypoplasia of the pyriform aperture. To correct this, many procedures have been applied, but still many problems are present. Authors performed the inlay and onlay insertion of porous high density polyethylene sheet(1 mm thickness $Medpor{(R)}$ sheet) in the hypoplastic pyriform margin of cleft side and obtained satisfactory results. Methods: 11 cases were performed and the mean follow up period was 15.1 months. Their mean age was 23.6 years. Under general anesthesia, bilateral pyriform margin was exposed. $Medpor{(R)}$ sheets in "match stick" like shaped were inlay inserted, and kidney shaped were onlay inserted fixating with two 6 mm titanium screws. After the surgery, the results was evaluated by photogrammetric analysis. On the basal view, the distance from the subalare and labiale superius' to the transverse baseline connecting the both cheilions was measured from the cleft side and the non-cleft side. Then, the postoperative symmetry was assessed by obtaining the cleft side against the non-cleft side as proportion index, defined as lateral and medial upper lip contour index. Results: There were 2 infections. The cause was because the inserted implant was too long and thus protruded to the base of nasal cavity. The lateral upper lip contour index was from 95.49 to 103.27, and medial upper lip contour index was from 90.92 to 100.49, it was statistically increased, and thus the symmetry was improved. However clinically mild depression remained at nostril floor. Conclusion: Authors performed porous high density polyethylene sheet inlay and onlay insertion for the hypoplasia of the pyriform margin in unilateral cleft lip nasal deformity. It was found that depressed pyriform margin and upper lip were corrected effectively except for the nostril floor, for which an additional soft tissue augmentation would be necessary. The inlay insertion has risk of protrusion, thus the guideline of the use of artificial prosthesis should be observed strictly.

보이드 재료에 대한 새로운 항복함수의 제안 (A New Yield Function for Voided Materials)

  • 김성태
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2000년도 춘계학술대회논문집
    • /
    • pp.13-16
    • /
    • 2000
  • In this paper the authors proposed a new anisotropic yield criterion for porous ductile materials. By using the proposed yield criterion and its flow rules a damage evolution of anisotropic sheet under biaxial tensile loading is investigated. A comparison of yield locus and damage evolution between the proposed yield criterion and experiments are carried out. the results are in good agreement.

  • PDF

미생물토양시트를 충진한 도로포장용 다공성 콘크리트의 제조 및 수질정화특성 (Preparation and Water Quality Purification of Permeable Concrete Pavement Filled with Microbial-Soil Sheet)

  • 강영현;황필기;강선홍
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.727-733
    • /
    • 2009
  • This study was performed to investigate the physical characteristics like compressive strength, permeability, porosity and the water quality removal characteristics of permeable concrete pavement filled with microbial-soil sheet to remove SS, organic matter and nutrients in artificial rainfall. As a result, it can show the removal efficiency is SS 90~95%, COD 85~93%, BOD 80~83%, T-N 61~75%, T-P 71~78% on WAPS I(W1) and WAPS II(W2). Therefore, permeable concrete pavement filled with microbial-soil sheet shows higher removal efficiency(SS 10%, organic matter and nutrients 30%) than a conventional porous concrete(W3). By filling microbial-soil sheet to permeable concrete pavement, we confirm that the function and efficiency are improved significantly and that a naturally-friendly facility can be developed and applied to treat non-point sources.

Approximate Yield Criterion for Voided Anisotropic Ductile Materials

  • Kim, Youngsuk;Sungyeun Won;Kim, Dogsoo;Hyunsung Son
    • Journal of Mechanical Science and Technology
    • /
    • 제15권10호
    • /
    • pp.1349-1355
    • /
    • 2001
  • As most fractures of ductile materials in metal forming processes occurred due to the results of evolution of internal damage - void nucleation, growth and coalescence. In this paper, an approximate yield criterion for voided (porous) anisotropic ductile materials is developed. The proposed approximate yield function is based on Gurson's yield function in conjunction with the Hosford's non-quadratic anisotropic yield criterion in order to consider the characteristic of anisotropic properties of matrix material. The associated flow rules are presented and the laws governing void growth with strain are derided. Using the proposed model void growth of an anisotropic sheet under biaxial tensile loading and its effect on sheet metal formability are investigated. The yield surface of voided anisotropic sheet and void growth with strain are predicted and compared with the experimental results.

  • PDF

온도 조절을 통한 다공성 폴리우레탄 동정맥 누관의 개발 (Development of Porous polyurethane Arterial-Venous Shunt by Thermal Control)

  • 정재승;유규하;김종원;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.478-481
    • /
    • 1997
  • A technique or the preparation of porous polyurethane vascular prostheses was investigated. Small-diameter vessels are not in general clinical use due to their limited long-term biocompatibility and low patency rates in experimental trial. These limits are mainly due to the failure of mechanical unction of the vascular grafts. This failure has been suggested to result partially from compliance mismatch. The long-term patency is considered to depend critically on the properties of the material and the fabrication process of the graft. So the control of pores is very important and main points to develop a available vascular grafts. Two-kind polymer sheets was compared. One was the porous PU-sheet made at room temperature by the solvent/non-solvent exchange. And the other was the porous PU-sheet which was fabricated by thermal phase transition and solvent-/non-solvent exchange using the thermal controller. The polymer sheets had a uniform pore size and pore occupation. According to the result of the above experiments, polyurethane solution was injected into a mold designed or U-type tube. The average pore size and pore occupation were easily changed by changing polyurethane concentration, freezing temperature, and methods. This technique can give a proper pore size ($10{\sim}45\;{\mu}m$) or tissue in growth, and suitable compliances or matching with arteries and veins. Besides, the fabrication of more complicated shaped vessels such as the U-type vascular grafts is easily controlled by using the fixed mold. this method might give a desired compliant graft or artificial implantation with the presently valid medical polymers.

  • PDF

다공성 니켈지지체의 제조에 관한 연구 (A Study on the Fabrication of Porous Nickel Substrates)

  • 신동엽;조원일;백지흠;조병원;강탁;윤경석
    • 한국표면공학회지
    • /
    • 제28권3호
    • /
    • pp.123-132
    • /
    • 1995
  • While a nickel mesh and an expanded nickel sheet are used as current collectors for supporting active anode materials in rechargeable batteries, a porous nickel substrate is studied extensively for its 3-dimensional structure which has high capabilities for active materials and current collection. Optimum plating conditions were studied by polarization measurement. Scanning Electron Microscopy (SEM) showed that both electroless-and electro-plated nickel on an urethane substrate were highly porous and consisted of nearly spherical pores. The diameter and the channel size of the pores were found to be 300~500 $\mu\textrm{m}$ and 50~200$\mu\textrm{m}$, respectively. The shape of skeleton resembled a triangular prism with length extending about 50~100 $\mu\textrm{m}$.

  • PDF

다공성 패드를 갖는 챔버의 배열에 따른 공기 부상 테이블의 비접촉 부상 수준에 대한 연구 (Non-Contact Level on Air Levitation Table with Porous Chamber Array)

  • 김준현;정영석;이태걸;김태훈;정효재
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.913-920
    • /
    • 2013
  • This paper presents an applicable basic design that can configure non-contact levitation table for conveying a large sheet of glass. The suggested air levitation table consists of a series of air chambers with porous pads and fans as the conveyor system. The air supply chambers are arrayed to supply an adequately strong upward airflow for supporting the glass. Levitation is controlled by the size and discharge velocity, of the chamber arrays, as well as the glass supporting height. After pre-evaluation of the glass rigidity and the filer functional performance, a one-way fluid structure interface (FSI) analysis is performed for predicting pressure and deflection working of the 8G glass in the transverse and longitudinal directions, respectively. After comparing calculated levels of flatness of the glass, it determines the chamber array for the linear non-contact conveying motion.

중공 원통형 고체연료의 열분해 및 연소특성 (The characteristics of pyrolysis and combustion for a hollow cylindrical solid fuel)

  • 민성기;김호영
    • 대한기계학회논문집
    • /
    • 제13권3호
    • /
    • pp.517-527
    • /
    • 1989
  • 본 연구에서는 국내 난방용 주연료인 연탄의 연소특성의 규명을 위한 기본 모델로서 일차적으로 형상을 단순화한 중공 원통형 고체연료의 연소모델을 개발하여 고체연료의 열분해 및 열분해 가스의 연소현상을 이론적으로 고찰하여 고체연료의 연속특성을 규명한다.

Reconstruction of extended orbital floor fracture using an implantation method of gamma-shaped porous polyethylene

  • Hwang, Woosuk;Kim, Jin Woo
    • 대한두개안면성형외과학회지
    • /
    • 제20권3호
    • /
    • pp.164-169
    • /
    • 2019
  • Background: The conventional surgical method for reconstructing orbital floor fractures involves restoration of orbital continuity by covering an onlay with a thin material under the periorbital region. However, in large orbital floor fractures, the implant after inserting is often dislocated, leading to malposition. This study aimed to propose a novel implanting method and compare it with existing methods. Methods: Among patients who underwent surgery for large orbital floor fractures, 24 who underwent the conventional onlay implanting method were compared with 21 who underwent the novel ${\gamma}$ implanting method that two implant sheets were stacked and bent to resemble the shape of the Greek alphabet ${\gamma}$. When inserting a ${\gamma}$-shaped implant, the posterior ledge of the orbital floor was placed between the two sheets and the bottom sheet was impacted onto the posterior wall of the maxilla to play a fixative role while the top sheet was placed above the residual orbital floor to support orbital contents. Wilcoxon signed-rank test and Mann-Whitney U test were used for data analyses. Results: Compared to the conventional onlay method, the gamma method resulted in better restoration of orbital contents, better improvement of enophthalmos, and fewer revision surgeries. Conclusion: Achieving good surgical outcomes for extended orbital floor fractures is known to be difficult. However, better surgical outcomes could be obtained by using the novel implantation method of impacting a ${\gamma}$-shaped porous polyethylene posteriorly.