• 제목/요약/키워드: Pore structure analysis

검색결과 296건 처리시간 0.023초

활성탄의 표면 구조 변화에 따른 흡착 특성 연구 (Adsorption properties of surface - modified activated carbon)

  • 김정렬;서문원;신창호;김영호;이근회;지상운
    • 한국연초학회지
    • /
    • 제16권2호
    • /
    • pp.191-197
    • /
    • 1994
  • Relationships between surface structure and adsorption properties of smoke components were investigated in surface-modified and un-modified activated carbon filter cigarettes. Commercially available activated carbon was treated with nitric acid and hydrogen peroxide as oxidant, and their pore volume, surface structure, BET surface area, pore type and size were studied. BET surface area and pore volume were decreased by nitric acid treatment, but median pore diameter was 8.1 $\AA$, which showed better development of pore compared with that of un-modified activated carbon, 6.9 $\AA$. In case of hydrogen peroxide treatment, BET surface area and pore volume were increased. Their pore was found to be a slit type based on V-t plot analysis. Neutralization capacities for bases of different strength (NaHCO3, Na2CO3, NaOEt and NaOH) showed that the majority of the acidic surface groups are of weak acidity. Modification of the activated carbon surface led to a slight change in adsorption properties when analyzing the smoke of triple-filter cigarette with surface-modified activated carbon.

  • PDF

A Study of the Optimum Pore Structure for Mercury Vapor Adsorption

  • Kim, Byung-Joo;Bae, Kyong-Min;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권5호
    • /
    • pp.1507-1510
    • /
    • 2011
  • In this study, mercury vapor adsorption behaviors for some kinds of porous materials having various pore structures were investigated. The specific surface area and pore structures were studied by BET and D-R plot methods from $N_2$/77 K adsorption isotherms. It was found that the micropore materials (activated carbons, ACs) showed the highest mercury adsorption capacity. In a comparative study of mesoporous materials (SBA-15 and MCM-41), the adsorption capacity of the SBA-15 was higher than that of MCM-41. From the pore structure analysis, it was found that SBA-15 has a higher micropore fraction compared to MCM-41. This result indicates that the mercury vapor adsorptions can be determined by two factors. The first factor is the specific surface area of the adsorbent, and the second is the micropore fraction when the specific surface areas of the adsorbent are similar.

Nitrogen Adsorption Analysis of Wood Saccharification Residues

  • Yang, Han-Seung;Tze, William Tai Yin
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권2호
    • /
    • pp.232-242
    • /
    • 2017
  • The objective of this study was to examine changes in the porosity and internal structure of wood as it goes through the process of saccharification (extraction of fermentable sugars). This study also examined the use of different drying methods to prepare samples for characterization of internal pores, with particular emphasis on the partially disrupted cell wall. Aspen wood flour samples after dilute acid pretreatment followed by enzymatic hydrolysis were examined for nitrogen adsorption. The resulting isotherms were analyzed for surface area, pore size distribution, and total pore volume. Results showed that freeze drying (with sample pre-freezing) maintains the cell wall structure, allowing for examination of saccharification effects. Acid pretreatment (hemicellulose removal) doubled the surface area and tripled the total volume of pores, which were mostly 10-20 nm wide. Subsequent enzymatic hydrolysis (cellulose removal) caused a 5-fold increase in the surface area and a ~ 11-fold increase in the total volume of pores, which ranged from 5 to 100 nm in width. These results indicate that nitrogen adsorption analysis is a feasible technique to examine the internal pore structure of lignocellulosic residues after saccharification. The information on the pore structure will be useful when considering value-adding options for utilizing the solid waste for biofuel production.

고로슬래그미분말 콘크리트의 초기재령특성과 중성화에 관한 연구 (A Study on Characteristics of Early Age Pore-structure and Carbonation of Ground Granulated Blast Furnace Slag Concrete)

  • 변근주;박성준;하주형;송하원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.107-110
    • /
    • 1999
  • The objective of this study is to obtain characteristics of early age pore-structure and carbonation of concrete using ground granulated blast furnace slag (GGBFS). The durability of GGBFS concrete should be evaluated for wide use of the GGBFS. As for that evaluation, an analysis on early age pore-structure characteristics of GGBFS concrete are very important, Carbonation depths of GGBFS concrete, which are known to be larger than that of OPC, are different according to replacement ratios and fineness of slag. Because sea sand as fine aggregate is much used recently, it is also necessary to analyze characteristics of carbonation of GGBFS concrete. In this study, The micro-pore structure formation characteristics of GGBFS concrete are obtained through the test of GGBFS mortars with different fineness and replacement ratio of GGBFS. The carbonation of GGBFS concrete is also investigated by acclerated carbonation test for early age GGBFS concrete.

  • PDF

$H_2O$ 증착법에 의한 알루미나 시멘트 경화체의 기공구조 연구 (A Study on the Pore Structure of Hardened Alumina Cement Pste by Water Vapor Sorption)

  • 임용무;장복기
    • 한국세라믹학회지
    • /
    • 제30권4호
    • /
    • pp.273-278
    • /
    • 1993
  • Using water vapor (de)sorption isotherm, pore structure analyses were performed for hardened cement pastes by a combination of the "MP-method" for the micropores and the "corrected modelless method" for the wide pores. This work was carried out to investigate the pore structure and to understand the microstructural basis of alumina cement developing much higher strength than Portland cement. Alumina cement shows extremely low microporosity and its wide pores are also composed mainlyof pores with very small radii. And the pore structure analysis results are consistent with the high strength property of alumina cement.y of alumina cement.

  • PDF

모서리가 제거된 팔면체 인장모델을 이용한 다공성 폴리머 박막의 반복변형거동 수치해석 (Numerical Analysis of Cyclic Deformation of Polymer Foam Film Using Stretched Truncated Octahedron Model)

  • 유위경;이영석
    • 한국정밀공학회지
    • /
    • 제27권3호
    • /
    • pp.104-110
    • /
    • 2010
  • Cyclic deformations of polymer foam film are simulated using the finite element method. Material of polymer foam film is polypropylene (PP). The calculated polymer foam film is micro-scale thin film has cellular structure. The polymer foam film is used in ferro-electret applications. The polymer foam film is idealized to one cell structure as lens shaped stretched truncated octahedron model. Cyclic deformation is performed by uniaxial stretching. Stretching direction is perpendicular to plane of cellular film. Various cyclic strain amplitudes, pore wall thicknesses, pore shape are investigated to find deformation tendency of cellular structure. Consequently, cellular structure has various macroscopic stresses on cyclic deformation with various pore thickness and pore shape.

고로슬래그 미분말 혼입 시멘트 페이스트의 프랙탈 특성에 관한 기초적 분석 (Basic Analysis on Fractal Characteristics of Cement Paste Incorporating Ground Granulated Blast Furnace Slag)

  • 김지영;최영철;최성철
    • 콘크리트학회논문집
    • /
    • 제29권1호
    • /
    • pp.101-107
    • /
    • 2017
  • 본 연구는 시멘트계 재료의 프랙탈 특성에 관한 기초적 연구로써, 고로슬래그 미분말 혼입 시멘트 페이스트의 공극 구조를 수은압입법을 이용하여 측정하였고, 측정된 결과를 프랙탈 모델에 적용하여 그 특성을 분석하였다. 분석 결과, 고로슬래그미분말 혼입 시멘트 페이스트의 공극 구조는 그 범위가 나노미터부터 밀리미터 단위까지 다양하게 분포하는 불규칙한 조직이기 때문에, 전체 영역에 대한 프랙탈 차원을 산정했을 때 각 공극 영역의 특성을 반영할 수 없다. 따라서 프랙탈 차원 산정 시 공극 영역을 나누어서 분석하였다. Zhang and Li (1995) model을 적용했을 때, 시멘트와 GGBFS의 수화반응 결과 생성된 C-S-H 내의 gel pores 및 small capillary pores에 해당하는 micro 영역과 large capillary pores에 해당하는 macro 영역에서 각각 프랙탈 특성이 나타나는 결과를 보였다. 또한 macro 영역보다 micro 영역의 공극 표면이 더 불규칙한 형상을 나타내었다. Ji et al. (1997) model을 적용할 경우, micro 영역이 C-S-H 내의 gel pores에 해당하는 micro I과 small capillary pores에 해당하는 micro II로 구분되었으며, 각각의 프랙탈 특성이 산정되었다. 또한 Zhang and Li (1995) model을 결과와 유사하게, macro, micro II, micro I의 순서대로 공극 크기가 작아질수록 VFD 결과 값이 감소하였으며, 이는 곧 공극의 복잡성이 증가함을 나타낸다.

발포 금속을 사용하는 채널의 열전달 특성 실험 및 해석 (Experiment and Analysis on the Heat Transfer Characteristics of a Channel Filled with Metal Form)

  • 손영석;신지영;조영일
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.448-453
    • /
    • 2010
  • Porous media containing complex fluid passage have especially large surface area per unit volume. This study is aimed to identify the heat transfer characteristics of high-porosity metal foams in a horizontal channel. Experiment is performed under various heat flux, velocity and pore density. Nusselt number decreases with higher pore density. Metal foams shows higher heat transfer coefficients than pin-fin structure with the same porosity. This is due to the more complex flow passage and larger heat transfer area based on the structure of the metal foams. The analysis on the pin-fin structure may not be suitable to the metal foam structure but should be identified extensively through further study.

야자계 활성탄을 활용한 폼 복합체의 미세기공 구조특성 (Characteristics of Micro-pore Structure of Foam Composite using Palm-based Activated Carbon)

  • 최영철;유성원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.157-164
    • /
    • 2021
  • 최근 미세먼지와 관련된 환경문제를 개선하기 위해 유해물질을 제거할 수 있는 광촉매와 흡착제에 대한 연구가 활발히 진행되고 있다. 본 연구에서는 전체 공극량이 일반 건설재료에 비해 상당히 큰 폼 콘크리트에 다량의 마이크로 공극를 갖는 야자계 활성탄소를 이용해서 다공성 폼 복합체를 제작하였다. 미세먼지 흡착 가능성을 평가하기 위해 제작된 폼 복합체에 대해 공극 구조를 분석하였다. 폼 복합체의 공극구조 분석은 측정된 질소 흡착등온선으로부터 BET와 Harkins-jura이론을 적용하였다. 분석결과 활성탄소를 혼입한 폼 복합체의 비표면적과 마이크로 공극 부피가 Plain보다 크게 증가하였다. 활성탄소 혼입율이 증가할수록 폼 복합체의 비표면적과 마이크로 공극 부피가 증가하는 경향을 나타냈다. 이는 폼 복합체가 가스상의 미세먼지 전구물질 NOX에 대한 흡착성능이 높을 것으로 보인다.

시멘트 및 고로슬래그 경화체의 양생환경에 따른 미세 공극구조 형성 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Microporous Structure Formation by Curing Condition of Cement and Blast Furnace Slag Composite)

  • 박철;정연식;서치호
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.63-70
    • /
    • 2017
  • When industrial by-products like slag and fly ash are using in concrete with cement, it improves strength and durability against external deterioration factors by densifying the structure through potential hydraulic and pozzolanic reaction. But it has been pointed out that high dependence on the quality variation and the curing condition using a admixure material for concrete. In this study, the characteristics of internal micropore structure according to curing condition were analyzed for pastes and mortar specimens under using blast furnace slag powder. As a result, the variation of compressive strength and the internal microstructure were observed according to curing conditions by binder type. Particularly, using blast furnace slag powder, decrease in compressive strength were clearly observed in indoor and carbonation curing compared with water curing. The pore structure analysis also clearly observed the decrease of the gel pore existing in the CSH hydrate layer and the increase of the capillary pore in indoor and carbonation curing compared with water curing condition.