• Title/Summary/Keyword: Porcelain metal

Search Result 264, Processing Time 0.027 seconds

Comparative study of fracture strength depending on the occlusal thickness of full zirconia crown (완전 지르코니아 크라운의 교합면 두께에 따른 파절강도의 비교 연구)

  • Jang, Soo-Ah;Kim, Yoon-Young;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the fracture strength of traditional metal-ceramic crowns and full zirconia crowns according to the occlusal thickness. Materials and methods: A mandibular first molar resin tooth was prepared with 1.5 mm occlusal reduction, 1.0 mm rounded shoulder margin and $6^{\circ}$ taperness in the axial wall. Duplicating the resin tooth, 64 metal dies were fabricated. 48 full zirconia crowns were fabricated using Prettau zirconia blanks by ZIRKONZAHN CAD/CAM and classified into six groups according to the occlusal thickness (0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16 metal-ceramic crowns were fabricated and classified into two groups according to the occlusal porcelain thickness (1.0 mm, 1.5 mm). All crowns were cemented on each metal die and mounted in a universal testing machine. The load was directed at the functional cusp of each specimen until catastrophic failure occurred. One-way ANOVA, Tukey multiple comparison test (${\alpha}=.05$) and t-test (${\alpha}=.05$) were used. Results: The results were as follows. 1. The test 1 group (646.48 N) showed the lowest fracture strength (P<.05), and the value of the test 2.3.4.5 groups (866.40 N, 978.82 N, 1196.82 N, 1222.41 N) increased as thickness increased, but no significant difference were found with the groups (P>.05). The value of test 6 group (1781.24 N) was significantly higher than those of the other groups (P<.05). 2. There were no significant differences of the fracture strength of metal ceramic crowns according to occlusal porcelain thickness 1.0 mm (2515.71 N) and 1.5 mm (3473.31 N) (P<.05). Conclusion: Full zirconia crown needs to be 1.0 mm or over in occlusal thickness for the posterior area to have higher fracture strength than maximum bite force.

A Study on the Life Expectancy of the Dental Prosthetic Restorations (치과보철물의 평균수명에 관한 연구)

  • Young-Ku Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.317-325
    • /
    • 1995
  • This study was performed to investigate the mean life expectancy of dental prosthetic restorations. The author has examined 352 dental prosthesis clinically and radiologically, and decided the success(survival) and failure(mortality) of the dental prosthesis. The dental prosthesis which had been treated in the Seoul National University Dental Hospital, two private clinics in Seoul, one university dental hospital, and two private clinics in local province were included in this study. The survival analysis using product limit estimator was used and the mean life expectancy of each type of dental prosthesis was calculated. The results were as follows : 1. The life expectancies were 10.5 years in gold crown and bridge, 8.5 years in porcelain fused to metal crown and bridge, 8.3 years in nonprecious metal crown and bridge, 8.1 years in removal partial denture, and 7.7 years in full denture. 2. The causes of mortality were in the order of dental caries(24.6%), fracture of dental prosthesis(19.2%), periodontal problems(18.6%), chronic chewing difficulty and dysfunction due to dental prosthesis(15.0%), excessive exposure of abutments due to the marginal defect of dental prosthesis(14.4%), abnormal occlusion due to severe attrition of artificial teeth in dentures(3.0%), periapical problems(2.4%), perforation of dental prosthesis(1.8%), and loose contacts with neighboring tooth(1.2%). 3. Among survival cases, 66.5% showed normal chewing ability and 31.9% showed partial chewing ability. However, 1.6% of them complained loss of chewing ability. 4. Among failure cases, 6.6% showed normal chewing ability and 38.9% showed partial chewing ability. However, 54.5% of them complained loss of chewing ability.

  • PDF

Dental materials in patients with oral mucosal disease based on the results of patch test study (구강점막질환환자에서 치과재료를 이용한 첩포시험 결과에 대한 고찰)

  • Jeong, Sung-Hee;Kim, Ji-Su;Kim, Kyung-Hee;Ok, Soo-Min;Heo, Jun-Young;Ahn, Yong-Woo
    • The Journal of the Korean dental association
    • /
    • v.52 no.2
    • /
    • pp.96-104
    • /
    • 2014
  • The aim of this study was to investigate the frequency of positive patch test reaction to dental materials in patients with oral mucosal diseases. Epicutaneous patch test was performed in 110 patients with oral mucosal diseases; 41 patients with oral lichen planus(OLP), 44 patients with burning mouth syndrome(BMS), 25 patients with other oral mucosal diseases including recurrent aphthous ulcer and mucous membrane pemphigoid. The obtained results were as follows: Oral gold restorations were most common in patents with oral mucosal diseases and porcelain fused metal crown, implant appeared in the order. 33 of 110 patients did not appear skin reactions (negative, 30%) and 77 patients (positive, 70%) had skin reactions including redness, rash, blisters. Dental materials causing positive reaction to patch test were mainly as gold-sodium-thiosulfate (26.7%), nickel sulfate(Ni) (22.7%), cobalt chloride(Co) (14.7%), palladium chloride(Pd) (11.9%), potassium dichromate (10.7%) in order, respectively. In conclusion, old metal restorations could be the cause of oral mucosal diseases and epicutaneous patch test could be used as a tool to improve the oral conditions.

A study on the shear bond strengths of veneering ceramics to the colored zirconia core (착색지르코니아 코어와 전장 도재 사이의 전단결합강도에 관한 연구)

  • Kang, Sun-Nyo;Cho, Wook;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.312-319
    • /
    • 2009
  • Statement of problem: Delamination of veneering porcelain from underlying ceramic substructures has been reported for zirconia-ceramic restorations. Colored zirconia cores for esthetics have been reported that their bond strength with veneered porcelain is weaker compared to white zirconia cores. Purpose: This study aimed to investigate the shear bond strength by manufacturing the veneering porcelain on the colored zirconia core, using the layering technique and heat-pressing technique, and to evaluate the clinical stability by comparing the result of this with that of conventional metal ceramic system. Material and methods: A Metal ceramic (MC) system was tested as a control group. The tested systems were Katana zirconia with CZR (ZB) and Katana Zirconia with NobelRondo Press (ZP). Thirty specimens, 10 for each system and control, were fabricated. Specimen disks, 3 mm high and 12 mm diameter, were fabricated with the lost-wax technique (MC) and the CAD-CAM (ZB and ZP). MC and ZB specimens were prepared using opaque and dentin veneering ceramics, veneered, 3 mm high and 2.8 mm in diameter, over the cores. ZP specimens were prepared using heat pressing ingots, 3 mm high and 2.8mm in diameter. The shear bond strength test was performed in a Shear bond test machine. Load was applied at a cross-head speed of 0.50 mm/min until failure. Mean shear bond strengths (MPa) were analyzed with the One-way ANOVA. After the shear bond test, fracture surfaces were examined by SEM. Results: The mean shear bond strengths (SD) in MPa were MC control 29.14 (2.26); ZB 29.48 (2.30); and ZP 29.51 (2.32). The shear bond strengths of the tested systems were not significantly different (P > .05). All groups presented cohesive and adhesive failures, and showed predominance of cohesive failures in ceramic veneers. Conclusion: 1. The shear bond strengths of the tested groups were not significantly different from the control group (P >.05). 2. There was no significant different between the layering technique and the heat pressing technique in the veneering methods on the colored zirconia core. 3. All groups presented cohesive and adhesive failures, and showed predominance of cohesive failures in ceramic veneers.

Fiber Reinforced Inlay Adhesion Bridge

  • Cho, Lee-Ra;Yi, Yang-Jin;Song, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.366-374
    • /
    • 2000
  • FRC/ceromer system provides the clinician with a durable, flexible, and esthetic alternative to conventional porcelain fused to metal crowns. FRC is the matrix which is silica-coated and embedded in a resin matrix. The ceromer material which is a second generation indirect composite resin contains silanized, microhybrid inorganic fillers embedded in a light-curing organic matrix. FRC/ceromer restoration has a several advantages: better shock absorption, less wear of occluding teeth, translucency, color stability, bonding ability to dental hard tissues, and resiliency. It has versatility of use including inlay, onlay, single crown, and esthetic veneers. With adhesive technique, it can be used for single tooth replacement in forms of inlay adhesion bridge. In single tooth missing case, conventional PFM bridge has been used for esthetic restoration. However, this restoration has several disadvantages such as high cost, potential framework distortion during fabrication, and difficulty in repairing fractures. Inlay adhesion bridge with FRC/ceromer would be a good alternative treatment plan. This article describes a cases restored with Targis/Vectris inlay adhesion bridge. Tooth preparation guide, fabrication procedure, and cementation procedure of this system will be dealt. The strength/weakness of this restoration will be mentioned, also. If it has been used appropriately in carefully selected case, it can satisfy not only dentist's demand of sparing dental hard tissue but also patient's desire of seeking a esthetic restorations with a natural appearance.

  • PDF

Leucite Synthesis from Solid-State Sintering (고상법에 의한 Leucite 합성)

  • Yoon, Dong-Sup;Lee, Byung-Ha
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.4
    • /
    • pp.282-286
    • /
    • 2005
  • Leucite crystal has been utilized for dental porcelain due to its high thermal expansion coefficient to meet its counter metal side. Many industrial applications of leucite from the incongruently melting of potassium feldspar are used and its minimum temperature of crystallization is $1150^{\circ}C$. This study aimed to get leucite crystal from lower temperature through congruently melting, and the starting materials are taken from K-feldspar mainly, and aluminum hydroxide and potassium carbonate are additionally supplied to meet stoichiometry of leucite. We report that the leucite crystal can be synthesized in congruently melting from the temperature $950^{\circ}C$ through solid-state sintering with k-feldspar, potassium carbonate and aluminum hydroxide.

Development of Working Platform for the Polymer Insulator String (송전선로 폴리머애자 공사용 장비 개발)

  • Min, Byeong-Wook;Wi, Shwa-Bok;Bang, Hang-Kwon;Choi, Han-Yeol;Baek, Soo-Gon;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.438-439
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea to insulate a transmission line from the tower, and a highly polymerized compound polymer insulator which has superior stain proof characteristics, has also been used widely. Currently, a worker rides on the suspension insulator string for installation on towers and conductors but in case of polymer insulators, this will pollute and scratch the housing result in durability reduction by deterioration and corona. This study developed a high strength aluminum compound metal lauder designed to work on polymer insulators without riding, and a clamp type connecting device and safety gear for easy installation on the tower and conductor. These polymer insulator work device can be used for 154kV and 345kV polymer insulators through a strength and load test to secure safety. This paper presents field usage.

  • PDF

THE FRACTURE RESISTANCE OF CERAMOMETAL CROWN WITH VARIOUS COPING DESIGN (Coping design에 따른 도재전장관의 파절강도에 관한 연구)

  • Chung Wan-Mo;Dong Jin-Keun;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.125-132
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of the metal coping design on the fracture resistance of ceramometal crown. The Ni-Cr alloy(Supranium, Krupp Co., German) and Vaccm-fired porcelain powder(Vita VMK 689, Vita Co., Germany) were used in this study. The measurement of fracture resisitance of ceramometal crown was done with Instron Universial Testing Machine(Instro Co., Model no.4201). The obained results were as fellows : 1. The fracture resistance measured at the buccal cusp tip was the highest value in the group that those position of ceramometal junction was 2mm superior to the lingual finshing margin(100.25Kg) and the fracture resistance revealed on order of the group that those position was 2mm buccal to the central groove(51.64Kg). 2. The fracture resistance measured at the central groove was higher value in the group that those position was 2mm lingual to the central groove than in the group that those position was 2mm lingual to the central groove than in the group that those position was 2mm superior to lingual finishing margin(132.48Kg). 3. In all cases, the fracture resistance at the central groove was higher than that at the buccal cusp tip.

  • PDF

Descriptive study on the procedure of dental prostheses at the dental laboratory in Seoul (치과기공소의 보철 기공물 제작 과정에 사용되는 재료 및 방법에 관한 실태조사 연구)

  • Hwang, Kyung-Sook
    • Journal of Technologic Dentistry
    • /
    • v.16 no.1
    • /
    • pp.57-77
    • /
    • 1994
  • The purpose of this study is to investigate the extent to which dental laboratories use proper materials, procedures, devices, and equipments to fabricate crown & bridge, PFM(Porcelain Fused to Metal) crown & bridge, partial denture, complete denture, and other prosteses. 100 laboratories in Seoul were selected for this investigation. Questionnaires were constructed focusing on five topocs:crown & bridge, PFM crown & bridge, partial denture, complete denture, and other prostheses. The results from this survey were as follows : 1. Most dental laboratories used old, inexpensive, and familiar materials rather than newly developed ones. 2. Most of the dental technicians did not stick to the standard procedures of handling materials, but to their own experiences. 3. Newly developed equipments to fabricate dental prostheses were possessed by nearly 30% dental laboratories. 4. About 80% of dental laboratories were using the procedures they had learned in the school : die trimming for accurate crown margin and softening heat treatment after RPD gold casting. But less than 30% of laboratories were shown to follow the boxing procedure to produce master cast and laboratory remounting in the process of complete denture. The findings show that dental laboratory procedures to fabricate dental prostheses are incomplete and inaccurate in some instances. So, further studies are neededs to clarify the causes of some inaccurate procedures, the better and more equipments should be supplied to produce the more accurate dental posthesis, and more efforts at enancing the appropriate use of dental materials and procedures should be made.

  • PDF

Study about shear bond strength of zirconia core used in dental prosthesis (치과 보철물에 사용되는 지르코니아 코어의 전단결합강도에 관한 연구)

  • Sim, Ji-Young;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2011
  • Purpose: This study aimed to investigate the shear bond strength by manufacturing the veneering porcelain on the IPS e.max $ZirCAD^{(R)}$ zirconia core, using the layering technique and heat-pressing technique, and to evaluate the clinical stability by comparing to the conventional metal ceramic system. Methods: The Schmitz-Schulmeyer test method was used to evaluate the core-veneer shear bond strength of zirconia core ceramic(IPS e.max $ZirCAD^{(R)}$) and their manufacture recommended two veneering ceramic systems(IPS e.max $ceram^{(R)}$, IPS e. max $ZirPress^{(R)}$). A metal ceramic system(Bellabond $plus^{(R)}$, VITA $VM13^{(R)}$) was used as a control group for the two all ceramic system test groups. The maximum loading and shear bond strength was measured. The average shear strength(MPa) was analyzed with the one-way ANOVA and the Tukey's test(${\alpha}$=.05). The fracture specimens were examined using Microscope to determine the failure pattern. Results: The mean shear bond strengths(SD) in MPa were MBSB control 43.62(2.13); ZBSB 18.65(1.76); ZPSB 18.89(1.54). The shear strengths of the zirconia cores were not significantly different(P>.05). Microscope examination showed that zirconia specimens presented mixed failure, and base metal alloy specimens showed adhesive failure. Conclusion: There was no siginificant different between the layering technique and the heat pressing technique in the veneering methods on the zirconia cores. None of the zirconia core and veneering ceramics could attain the high bond strength values of the metal ceramic combination.