• Title/Summary/Keyword: Pool water

Search Result 544, Processing Time 0.023 seconds

A Study on Development of Freshwater Fish Shelter and Evaluation of Water Quality for the Reduction of Thermal Stress in Shallow Pond (얕은 연못에서 담수 어류의 열성 스트레스 저감을 위한 피난처 개발 및 수질환경 조사 연구)

  • Lee, Saeromi;Ahn, Chang Hyuk;Joo, Jin Chul;Song, Ho Myeon;Park, Jae Roh
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.12
    • /
    • pp.828-836
    • /
    • 2014
  • The purpose of this study evaluates the water quality of artificial deep pool (ADP) during the late spring and summer. we monitored the water quality, as pH, dissolved oxygen (DO), temperature and conductivity at two stations (St. 1. open water, St. 2. in the ADP). The water quality in the ADP is very stable, and temperature and DO are lower than the open water (average value; temperature $1.4{\sim}3.2^{\circ}C$, DO 2.4~3.6 mg/L). In particular, daily variation of temperature in the open water showed above $4^{\circ}C$, but ADP remained stable. The water quality was analyzed using two-way analysis of variance (ANOVA). The results of the analysis showed difference about temperature, pH, DO, conductivity (two-way ANOVA, p<0.05). The ADP has created an aqua environment in thermal and DO gradients by depth. About 1.2 m, Temperature and DO were sharply decreased. The Rhodeus uyekii is dominant species in pond of this study. The ADP offers optimum water temperature ($16.5{\sim}18.5^{\circ}C$) to the Rhodeus uyekii about spawning. Consequently, the ADP offers stable habitat than open water for fish and aquatic organisms during the summer. It is also a good shelter for fish from a thermal stress.

Effect of Orientation on Pool Boiling Heat Transfer in Annulus with Small Gap (경사각이 좁은 틈새를 가지는 환상공간 내부 풀비등 열전달에 미치는 영향)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.237-244
    • /
    • 2011
  • An experimental study was carried out to investigate the effect of the inclination angle on the nucleate pool boiling of saturated water at atmospheric pressure. We considered an annulus with a gap of 5 mm and a bottom opening. The inner tube of the annulus was heated, and the outer diameter and the length of the tube were 25.4 mm and 500 mm, respectively. The inclination angle was varied from horizontal to vertical. The results were compared to those for an annulus with a larger gap and a single tube. In the small-gap annulus, the effect of the inclination angle on the heat transfer was not significant. However, an early onset of the critical heat flux was observed at 80 kW/$m^2$ when the annulus was horizontal. Liquid agitation and bubble coalescence were considered to be the major heat-transfer mechanisms.

Effects of Outflow Area on Pool Boiling in Vertical Annulus (출구유로 단면적이 수직 환상공간 내부의 풀비등에 미치는 영향)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.377-385
    • /
    • 2013
  • To identify the effects of an outflow area on pool boiling heat transfer in a vertical annulus, three different flow restrictors were studied experimentally. For the test, a heated tube of smooth stainless steel and water at atmospheric pressure were used. Both annuli with open and closed bottoms were considered. To validate the effects of the outflow area on the heat transfer, the results of the annulus with the restrictor were compared with the data for the plain annulus without the restrictor. The reduction of the outflow area ultimately results in a decrease in the heat transfer. As the outflow area is very small, a slight increase in heat transfer is also observed. The major cause of this tendency is explained as the difference in the intensity of liquid agitation cause by the movement of coalesced bubbles. It is identified that the convective flow, pulsating flow, and evaporative mechanism are considered as the important mechanisms.

Effects of Pitch on Pool Boiling from Horizontal Tube Array (피치가 수평 튜브 배열의 풀비등에 미치는 영향)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.719-726
    • /
    • 2017
  • An experimental study was performed to investigate the combined effects of the pitch and heat flux of nearby tubes on boiling in a pool as well as the heat transfer from a horizontally-installed tube bundle. For this test, two smooth stainless steel tubes (19 mm outside diameter) were used, and the water was at atmospheric pressure. The pitch of these tubes was varied between 28.5 mm and 95 mm, and the heat flux of the nearby tube altered between 0 and $90kW/m^2$. Enhancements in heat transfer were clearly observed when the heat flux of the nearby tube increased while the heat flux of the test section remained below $40kW/m^2$. The tube pitch was found to have a negligible effect on heat transfer when the pitch was greater than four times larger than the tube diameter. The circulating flow, convective flow, and liquid agitation were all seen to enhance heat transfer; however, the interaction between the flow and coalescence of bubbles was detrimental to heat transfer.

Experimental Analysis of the Parameters Governing Scour in Plunge Pool with Cohesionless Bed Material (침강지내 비점성하상의 세굴 지배인자에 대한 실험적 해석)

  • Son, Kwang Ik;Lee, Won Hwan;Cho, Won Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.123-129
    • /
    • 1993
  • Because the existing scour prediction formulas for plunge pools of pipe culverts and spillways give a wide range of predicted scour depths, it is difficult to estimate actual scour depths. A review of literature showed that wide range of predicted values was caused mostly by lack of thorough analysis of the scour mechanism. In this study, the effects of the parameters govering scour were examined, and the scour potentials were measured. The major variables govering scour were the velocity and size of jet impinging into the plunge pool, the submerged weight of bed material, the ratio of jet size to bed material size, the tail watr depth of the plunge pool, and the angle of jet impact on water surface. The ratio of jet size to bed material size to bed material size was found to be another significant parameter affecting scour for larger bed materials. A densimetric Froude nember of the bed material in incipient motion was formulated. This number represented the scour potential of the jet at the point where the bed material was tested.

  • PDF

Evaluation of the Effect of Riser Support System on Global Spar Motion by Time-domain Nonlinear Hull/Mooring/Riser Coupled Analysis

  • KOO BON-JUN;KIM MOO-HYUN
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.5 s.66
    • /
    • pp.16-25
    • /
    • 2005
  • The effect of vertical riser support system on the dynamic behaviour of a classical spar platform is investigated. Spar platform generally uses buoyancy-can riser support system, but as water depth gets deeper the alternative riser support system is required due to safety and cost issues. The alternative riser support system is to hang risers off the spar platform using pneumatic cylinders rather than the buoyancy-can. The existing numerical model for hull/mooring/riser coupled dynamics analysis treats riser as an elastic rod truncated at the keel (truncated riser model), thus, in this model, the effect of riser support system can not be modeled correctly. Due to this reason, the truncated riser model tends to overestimate the spar pitch and heave motion. To evaluate more realistic global spar motion, mechanical coupling among risers, guide frames and support cylinders inside of spar moon-pool should be modeled. In the newly developed model, the risers are extended through the moon-pool by using nonlinear finite element methods with realistic boundary condition at multiple guide frames. In the simulation, the vertical tension from pneumatic cylinders is modeled by using ideal-gas equation and the vertical tension from buoyancy-cans is modeled as constant top tension. The different dynamic characteristics between buoyancy-can riser support system and pneumatic riser support system are extensively studied. The alternative riser support system tends to increase spar heave motion and needs damper system to reduce the spar heave motion.

An Experimental Study of the Pool-Boiling CHF on Downward-Facing Plates (하향 평판에서의 풀비등 임계열유속에 관한 실험적 연구)

  • Yang, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.493-501
    • /
    • 1994
  • An experimental study has been peformed on the pool-boiling critical heat flux (CHF) phenomenon on downward -facing plates. The CHF for inclinations of -90$^{\circ}$(horizontally downward position), -88$^{\circ}$, -86$^{\circ}$, -84$^{\circ}$, -60$^{\circ}$ and -40$^{\circ}$ were measured using plate-type test sections of 20mm 200mm and 25mm 200mm in a pool of saturated water under atmospheric pressure. The measured CHF was lower for the wider test section and decreased as its orientation approached to the horizontally downward position. The lower CHF can be attributable to the increased difficulty for the bubbles in escaping from the heater surface. When compared with the previous works, the overall trends were similar; however, a transition angle, at which the decrease rate in the CHF was changed, was observed in the vicinity of -80$^{\circ}$.

  • PDF

Habitat selectivity of fresh water fishes of two second-order tropical streams in Tigray, Northern Ethiopia

  • Tesfay, Solomon;Teferi, Mekonen;Tsegazeabe, Haileselasie Hadush
    • Journal of Ecology and Environment
    • /
    • v.43 no.1
    • /
    • pp.73-83
    • /
    • 2019
  • Background: Habitat selectivity and ecology of freshwater fishes were studied in two selected streams and their junction point which consist a total of 39 microhabitats. The aims of this study were to describe the habitat preference and its availability to fish assemblage, as well as ecology, habitat use, and habitat characteristics. Methods: We collected fish with backpack electrofishing three times during August 2013, December 2013, and March 2014. Using a variation partitioning approach of R software, we studied the relationship of fish abundances with stream type, habitat type, and abundance of key macroinvertebrate taxa. Results: A total of 6554 fishes representing four species belonging to the family Cyprinidae were caught. A higher total fish abundance was recorded from Gereb Tsedo (4870; 74.3%) than from Elala stream (1684; 25.7%). Taking both streams together, the overall total relative fish abundance was significantly higher in pools (53%) than in runs (35%) and in riffles (12%) at P < 0.05. Species-wise comparisons showed that 71%, 15%, 13%, and 1% of the pool fish community were occupied by Garra blanfordii, Garra ignestii, Garra dembecha, and Garra aethiopica, respectively. Stream type, habitat type, and key macroinvertebrate taxa each explained a significant proportion of the variation in fish abundance. Based on the variation partitioning approach, fish abundance was higher in Gereb Tsedo stream (P < 0.01). Moreover, fish abundance increased with pool habitat type (P < 0.01) and with availability of key macroinvertebrate taxa (P < 0.01). Conclusion: Fish abundance differed between stream types, among habitats and among key macroinvertebrate taxa availability. Among the factors, habitat type was the most important driving factor behind variation among fish abundances, and pool supports the highest fish abundance.

Water-Simulant Facility Installation for the Sodium-Cooled Fast Reactor KALIMER-600 and Global Flow Measurement (소듐냉각고속로 KALIMER-600 축소 물모의 열유동 가시화 실험장치 구축 및 거시 유동장 특성 측정)

  • Cha, Jae-Eun;Kim, Seong-O
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.54-62
    • /
    • 2011
  • KAERI has developed a KALIMER-600 which is a pool-type sodium-cooled fast reactor with a 600MWe electric generation capacity. For a SFR development, one of the main topics is an enhancement of the reactor system safety. Therefore, we have a long-term plan to design the large sodium experimental facility to evaluate the reactor safety and component performance. In order to extrapolate a thermal hydraulic phenomena in a large sodium reactor, the thermal hydraulics phenomena is under investigation in a 1/$10^{th}$ water-simulant facility for the KALIMER-600. In this paper, we shortly described the experimental facility setup and the measurement of the isothermal global flow behavior. For the flow field measurement, the PIV method was used in a transparent Plexiglas reactor vessel model at around $20^{\circ}C$ water condition.

Accounting for Uncertainty Propagation: Streamflow Forecasting using Multiple Climate and Hydrological Models

  • Kwon, Hyun-Han;Moon, Young-Il;Park, Se-Hoon;Oh, Tae-Suck
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1388-1392
    • /
    • 2008
  • Water resources management depends on dealing inherent uncertainties stemming from climatic and hydrological inputs and models. Dealing with these uncertainties remains a challenge. Streamflow forecasts basically contain uncertainties arising from model structure and initial conditions. Recent enhancements in climate forecasting skill and hydrological modeling provide an breakthrough for delivering improved streamflow forecasts. However, little consideration has been given to methodologies that include coupling both multiple climate and multiple hydrological models, increasing the pool of streamflow forecast ensemble members and accounting for cumulative sources of uncertainty. The approach here proposes integration and coupling of global climate models (GCM), multiple regional climate models, and numerous hydrological models to improve streamflow forecasting and characterize system uncertainty through generation of ensemble forecasts.

  • PDF