• Title/Summary/Keyword: Polymer electrolyte membranes

Search Result 208, Processing Time 0.024 seconds

Characterization of PVdF/Laponite Reinforced Composite Membranes for PEMFC Surpport (PEMFC 지지체용 PVdF/Laponite 강화 복합막의 특성평가)

  • Oh, Seul-Gi;Hwang, Hae-Young;Kim, Hyoung-Juhn;Nam, Sang-Yong
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.159-168
    • /
    • 2010
  • In this study, high porous PVdF flat sheet membranes were prepared to obtain reinforced membrane support for polymer electrolyte membrane fuel cell. Nano-size laponite was randomly dispersed in the membranes to improve mechanical property which lowered by the high porosity. The morphology and porosity of prepared PVdF/Laponite composite membranes were examined using the SEM analysis and the weight method and all membranes showed over 60% porosity. The membrane thermal stability depending on the laponite contents in the composite membranes was evaluated by membrane heat shrinkage at $105^{\circ}C$ and $135^{\circ}C$. MD and TD heat shrinkage of the PVdF composite membrane containing 5 wt% laponite was 2~3% and 2~3.5% at $135^{\circ}C$, respectively. The mechanical strength was enhanced after incorporating laponite particles and 30% increase in the modulus compared to pure PVdF membrane was obtained.

A Review on Membranes and Catalysts for Anion Exchange Membrane Water Electrolysis Single Cells

  • Cho, Min Kyung;Lim, Ahyoun;Lee, So Young;Kim, Hyoung-Juhn;Yoo, Sung Jong;Sung, Yung-Eun;Park, Hyun S.;Jang, Jong Hyun
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.183-196
    • /
    • 2017
  • The research efforts directed at advancing water electrolysis technology continue to intensify together with the increasing interest in hydrogen as an alternative source of energy to fossil fuels. Among the various water electrolysis systems reported to date, systems employing a solid polymer electrolyte membrane are known to display both improved safety and efficiency as a result of enhanced separation of products: hydrogen and oxygen. Conducting water electrolysis in an alkaline medium lowers the system cost by allowing non-platinum group metals to be used as catalysts for the complex multi-electron transfer reactions involved in water electrolysis, namely the hydrogen and oxygen evolution reactions (HER and OER, respectively). We briefly review the anion exchange membranes (AEMs) and electrocatalysts developed and applied thus far in alkaline AEM water electrolysis (AEMWE) devices. Testing the developed components in AEMWE cells is a key step in maximizing the device performance since cell performance depends strongly on the structure of the electrodes containing the HER and OER catalysts and the polymer membrane under specific cell operating conditions. In this review, we discuss the properties of reported AEMs that have been used to fabricate membrane-electrode assemblies for AEMWE cells, including membranes based on polysulfone, poly(2,6-dimethyl-p-phylene) oxide, polybenzimidazole, and inorganic composite materials. The activities and stabilities of tertiary metal oxides, metal carbon composites, and ultra-low Pt-loading electrodes toward OER and HER in AEMWE cells are also described.

Synthesis and characterization of sulfonated poly(arylene biphenylsulfone ether) copolymers containing hydroquinone moiety for polymer electrolyte membrane (고분자 전해질 멤브레인용 하이드로퀴논 부분이 포함된 설폰화된 폴리(아릴렌 비페닐설폰 에테르) 공중합체의 합성과 특성평가)

  • Yoo, Dong-Jin
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.121-127
    • /
    • 2010
  • In present work, sulfonated poly(arylene biphenyklsulfone ether) copolymers containing hydroquinone moiety were successfully synthesized using 4,4'-bis[(4-chlorophenyl)sulfonyl]-1,1'-biphenyl(BCPSBP), hydroquinone sulfonic acid potassium salt(sHQ), 4,4'-sulfonyldiphenol and evaluated their characteristics. Three kinds of polymer electrolyte membranes, PBPSEH-HQ00, PBPSEH-HQ10 and PBPSEH-HQ30 were prepared by using mole fraction of sulfonated hydroquinone(sHQ). The structure of the fabricated polymers was analyzed using NMR, IR and GPC. The Mw(weight-average molecular weights) of the polymers were in the range of 62,000-213,000 g $mol^{-1}$, and the molecular weight distribution (Mw/Mn) varied from 1.66-4.04. The thermal analysis of the copolymers was carried out by TGA and DSC. The temperature of Td5% and Td10% was decreased with the mole fraction of sHQ but Tg was increased with the mole fraction. The water uptake, IEC and ion conductivity were increased with increasing the ionic cluster of the polymers. The proton conductivity equal to 9.4 mS $cm^{-1}$ was measured for the PBPSEH-HQ30 membrane at $90^{\circ}C$ and 100% relative humidity. From the observed results it is clear that the prepared hydrocarbon membrane can be considered as suitable polymer electrolyte membrane for the application of PEMFC.

Effect of O2 Plasma Treatment on Electrochemical Performance of Supercapacitors Fabricated with Polymer Electrolyte Membrane (고분자 전해질막으로 제조한 슈퍼커패시터의 전기화학적 특성에 대한 산소 플라즈마 처리 영향)

  • Moon, Seung Jae;Kim, Young Jun;Kang, Du Ru;Lee, So Youn;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.32 no.1
    • /
    • pp.43-49
    • /
    • 2022
  • Solid-state supercapacitors with high safety and robust mechanical properties are attracting global attention as next-generation energy storage devices. As an electrode of a supercapacitor, an economical carbon-based electrode is widely used. However, when an aqueous electrolyte is introduced, the charge transfer resistance increases because the interfacial contact between the hydrophobic electrode surface and aqueous electrolyte is not good. In this regard, we propose a method to obtain higher electrochemical performance based on improved interfacial properties by treating the electrode surface with oxygen plasma. The surface hydrophilization induced by the enriched oxygen functionalities was confirmed by the contact angle measurement. As a result, the degree of hydrophilization was easily adjusted by controlling the power and duration of the oxygen plasma treatment. As the electrolyte of the supercapacitor, PVA/H3PO4, which is a typical solid-state aqueous electrolyte, was used. Free-standing membranes of PVA/H3PO4 electrolyte were prepared and then pressed onto the electrode. The optimal condition was to perform oxygen plasma treatment for 5 seconds with a low power of 15 W, and the energy density of the supercapacitor increased by about 8%.

Hydrocarbon Composite Membranes with Improved Oxidative Stability for PEMFC (산화안정성 향상을 위한 고분자연료전지용 탄화수소복합막의 제조 및 특성연구)

  • Lee, Hyejin;Choi, Young-Woo;Yang, Tae-Hyun;Bae, Byungchan
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.1
    • /
    • pp.44-48
    • /
    • 2014
  • Sulfonated poly(arylene ether sulfone)-cerium composite membranes with improved oxidative stability were prepared for proton exchange membrane fuel cell application. Oxidative stability of the composite membranes changed depending on the amount of incorporated metal. Their water uptake, IEC and proton conductivity were also affected. ICP analysis confirmed trace of cerium ion in the composite membranes and $^1H$-NMR indicated successful coordination of sulfonic acid groups with the metal ions. Increasing amount of the cerium ion resulted in decrease in proton conductivities and water uptake, but enhanced oxidative stabilities. A hydrogen peroxide exposure equipment was used for the test of oxidative stability of the composite membranes, which enabled to mimic fuel cell operating condition compared with conventional Fenton's test.

Preparation and Characterization of Sulfonated Poly(Arylene Ether Sulfone) Random Copolymer Reinforced Membranes for Fuel Cells (연료전지용 술폰화 폴리아릴렌에테르술폰 랜덤공중합체 강화복합막의 제조 및 특성)

  • Ahn, Juhee;Lee, Chang Hyun
    • Membrane Journal
    • /
    • v.26 no.2
    • /
    • pp.146-151
    • /
    • 2016
  • Sulfonated poly (arylene ether sulfone) (SPAES) random copolymers have merits such as high proton conductivity, relatively low production cost, and thermochemical resistance when applied as polymer electrolyte membranes for fuel cells. However, it is difficult to directly employ SPAES copolymers into practical fuel cell membrane applications owing to their low chemical stability and dimensional instability under harsh operation conditions. A plausible solution is to impregnate SPAES copolymers into support films (e.g., electrospun polyimide support) with interconnected pore structures and high thermochemical toughness. In this study, a SPAES copolymer with a swivel group, which induces high free volume for fast ion transport, is chosen as ionomers to prepare pore-filling membranes (PFMs). The feasibility of the resulting membranes is evaluated via membrane characterizations.

Preparation of Self-humidifying Pt/Nafion Membranes using Supercritical $CO_2$ for PEMFCs (초임계유체를 이용한 PEMFC용 자가 가습 백금/나피온 막의 제조)

  • Byun, Jung-Yeon;Kim, Hyo-Won;Sung, Joon-Yong;Kim, Hwa-Yong
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.99-103
    • /
    • 2007
  • Pt/Nafion self-humidifying membranes for Polymer Electrolyte Membrane Fuel Cell (PEMFC) were synthesized via a supercritical-impregnation method. The Nafion 112 membranes were impregnated with Pt(II) acetylacetonate from a supercritical carbon dioxide ($scCO_2$) solution at $80^{\circ}C$ and 19.8 MPa. After the impregnation, the Pt-impregnated Nafion membrane was converted Pt deposited Nafion(Pt/Nafion) membrane by reducing agent, sodium borohydride ($NaBH_4$) under $50^{\circ}C$ and 2 hours. The prepared Pt/Nafion membranes were investigated by SEM, EDS and EPMA. The performance of the Pt/Nafion membranes was examined in PEMFC as a self-humidifying membrane. The cell performance of the Pt/Nafion membrane at $65^{\circ}C$ is better than that of Nafion 112.

  • PDF

Transport of Water through Polymer Membrane in Proton Exchange Membrane Fuel Cells (고분자전해질 연료전지에서 고분자막을 통한 물의 이동)

  • Lee, Daewoong;Hwang, Byungchan;Lim, Daehyun;Chung, Hoi-Bum;You, Seung-Eul;Ku, Young-Mo;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.338-343
    • /
    • 2019
  • The water transport and water content of the electrolyte membrane greatly affect the performance of the membrane in PEMFC(Proton Exchange Membrane Fuel Cell). In this study, the parameters (electroosmotic coefficient, water diffusion coefficient) of polymer membranes for water transport were measured by a simple method, and water flux and ion conductivity were simulated by using a model equation. One dimensional steady state model equation was constructed by using only the electro-osmosis and diffusion as the driving force of water transport. The governing equations were simulated with MATLAB. The electro-osmotic coefficient of $144{\mu}m$ thick polymer membranes was measured in hydrogen pumping cell, the value was 1.11. The water diffusion coefficient was expressed as a function of relative humidity and the activation energy for water diffusion was $2,889kJ/mol{\cdot}K$. The water flux and ion conductivity results simulated by applying these coefficients showed good agreement with the experimental data.

Synthesis and Characterization of Polybenzimidazoles Containing Perfluorocyclobutane Groups for High-temperature Fuel Cell Applications

  • Chang, Bong-Jun;Kim, Dong-Jin;Kim, Jeong-Hoon;Lee, Soo-Bok;Joo, Hyeok-Jong
    • Korean Membrane Journal
    • /
    • v.9 no.1
    • /
    • pp.43-51
    • /
    • 2007
  • This paper describes the preparation and characterization of two kinds of fluorinated polybenzimidazole (PBI)s which can be potentially used for phosphoric acid-doped, high-temperature polymer electrolyte membrane fuel cells. Two kinds of perfluorocyclobutane (PFCB)-containing monomers were prepared via following synthetic steps; after fluoroalkylation of methyl 3-(hydroxy) benzoate and methyl 4-(hydroxy) benzoate with 1,2-dibromotetrafluoroethane and subsequent Zn-mediated dehalogenation, these compounds were cyclodimerized at $200^{\circ}C$ affording the ester-terminated monomers containing PFCB ether groups. The synthesized intermediates and monomers were characterized using FT-IR, $^1H-NMR,\;^{19}F-NMR$, and mass spectroscopy. The fluorinated PBIs were then successfully prepared through the solution polycondensation of the monomers and 3,3'-diaminobenzidine in polyphosphoric acid. Compared with traditional PBI, the glass transition temperatures of the fluorinated PBIs were obtained at $262^{\circ}C\;and\;269^{\circ}C$ which are lower than that of PBI and their initial degradation temperatures were still high over $400^{\circ}C$ under nitrogen. The fluorinated PBIs showed higher d-spacing values and improved solubility in several organic solvents as well as phosphoric acid, which confirmed they could be good candidates for the high temperature fuel cell membranes.

Comparison of Membrane Degradation of PEMFC by Fenton Reaction and OCV Holding (Fenton 반응과 OCV Holding에 의한 PEMFC 고분자 전해질 막의 열화비교)

  • Oh, Sohyung;Kwag, Ahhyun;Lee, Daewoong;Lee, Mooseok;Lee, Donghoon;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.768-773
    • /
    • 2019
  • The Fenton reaction, which evaluates the electrochemical durability of polymer membranes of polymer electrolyte fuel cells (PEMFC), and the degradation of polymer membranes by OCV holding method are compared. The Fenton reaction is a method that can evaluate the chemical durability of the polymer membrane at outside the cell in a shorter time than the OCV Holding method. The Fenton reaction was carried out at 30% hydrogen peroxide, 10 ppm iron, and $80^{\circ}C$ for 24 hours. OCV Holding was driven at $90^{\circ}C$, 30% relative humidity and OCV for 168 hours. The Fenton reaction caused a lot of degradation inside the polymer membrane. On the other hand, in OCV Holding, the membrane thickness was thinned by the entire surface and internal degradation. The fluorine emission rate was more than 10 times higher than that of OCV Holding due to the Fenton reaction. The hydrogen permeation rate increased about 30% at 24 hours of Fenton reaction. At OCV Holding, hydrogen permeability decreased after 24 hours and then increased. As a whole, there was a difference in a membranes deteriorated by Fenton reaction and OCV Holding.