• Title/Summary/Keyword: Polymer Surface Alignment

Search Result 112, Processing Time 0.024 seconds

One-dimensional Nanomaterials for Field Effect Transistor (FET) Type Biosensor Applications

  • Lee, Min-Gun;Lucero, Antonio;Kim, Ji-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.165-170
    • /
    • 2012
  • One-dimensional, nanomaterial field effect transistors (FET) are promising sensors for bio-molecule detection applications. In this paper, we review fabrication and characteristics of 1-D nanomaterial FET type biosensors. Materials such as single wall carbon nanotubes, Si nanowires, metal oxide nanowires and nanotubes, and conducting polymer nanowires have been widely investigated for biosensors, because of their high sensitivity to bio-substances, with some capable of detecting a single biomolecule. In particular, we focus on three important aspects of biosensors: alignment of nanomaterials for biosensors, surface modification of the nanostructures, and electrical detection mechanism of the 1-D nanomaterial sensors.

Numerical Simulation of Heat and Flow Behaviors in Butt-fusion Welding Process of HDPE Pipes with Curved Fusion Surface (굴곡 융착면을 이용한 고밀도폴리에틸렌 관의 버트 융착 공정에서의 열유체 거동 수치모사)

  • Yoo, Jae Hyun;Choi, Sunwoong;Ahn, Kyung Hyun;Oh, Ju Seok
    • Korean Chemical Engineering Research
    • /
    • v.55 no.4
    • /
    • pp.561-566
    • /
    • 2017
  • Butt-fusion welding process is used to join the polymeric pipes. Recently, some researchers suggest the curved surface to enhance a welding quality. We investigated how curved welding surface affects heat and flow behaviors of polymer melt during the process in 2D axisymmetric domain with finite element method, and discussed the effect to the welding quality. In this study, we considered HDPE pipes. In heat soak stage, curved phase interface between the melt and solid is shown along the shape of welding surface. In jointing stage, squeezing flow is generated between curved welding surface and phase interface. The low shear rate in fusion domain reduces the alignment of polymer to the perpendicular direction of pipes, and then this phenomenon is expected to help to enhance the welding quality.

A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism (Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서)

  • Yun, Sung-Sik;Lee, Soo-Hyun;Ahn, Chong-H.;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.

Effect of Uniaxial Drawing Conditions on the Orientation of Poly (ethylene 2,6- naphthalate) (일축 연신 조건에 따른 Poly(ethylene 2,6-naphthalate) 배향에 관한 연구)

  • 진병석;이성효;이광희
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.699-706
    • /
    • 2001
  • The effects of uniaxial drawing conditions on the molecular orientation of poly (ethylene 2,6-naphthalate) (PEN) are investigated. Birefringence measurements show that the orientation is significantly enhanced at high draw ratio, low drawing temperature, and fast drawing speed. The characteristics of orientation examined by FTIR- ATR dichroism method represent almost same results. Amorphous orientation function increases with drawing rate at $120^{\circ}C$, but it decreases with drawing rate at $141^{\circ}C$. These behaviors can be explained with the relation between crystallization and chain relaxation rates. It is observed that the orientation of PEN film is accompanied by significant alignment of the naphthalene rings of PEN parallel to the film surface.

  • PDF

Carbonate Crystal Growth Controlled by Interfacial Interations of Artifical Cell Membranes

  • Goh, Dai-Young;Ahn, Dong-June
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.2 no.2
    • /
    • pp.109-112
    • /
    • 1997
  • Morphology of carbonate crystals grown on the surface of artificial cell membranes was controlled by changing the interfacial chemistry. For octadecyltriethoxysilane (OTE) films with terminal methyl groups interacting little with an aqueous calcium carbonate solution calcite (104) crystals were formed. Polymerized pentacosadiynoic acid (PDA) films with terminal carboxylic acid groups induced deposition of calcite (012) crystals aligned along with each other within a polymer domain. On the other hand, stearyl alcohol (StOH) films with terminal hydroxyl groups induced deposition of aragonite crystals. When PDA was mixed with StOH, the 8:1 PDA:StOH (molar ratio) film produced dominating calcite (012) crystals without any crystal alignment, and the 4:1 mixture film produced minor calcite (012) crystals and major aragonite crystals. For the 2:1, 1:1, 1:2, and 1:4 mixture films, aragonite crystals were dominating. Hence, it is found that the chemical composition at the interface plays a very important role in controlling the morphology of deposited carbonate crystals.

  • PDF

Experimental and microstructural evaluation on mechanical properties of sisal fibre reinforced bio-composites

  • Kumar, B. Ravi;Hariharan, S.S.
    • Steel and Composite Structures
    • /
    • v.33 no.2
    • /
    • pp.299-306
    • /
    • 2019
  • The natural fibre composites are termed as bio-composites. They have shown a promising replacement to the current carbon/glass fibre reinforced composites as environmental friendly materials in specific applications. Natural fibre reinforced composites are potential materials for various engineering applications in automobile, railways, building and Aerospace industry. The natural fibre selected to fabricate the composite material is plant-based fibre e.g., sisal fibre. Sisal fibre is a suitable reinforcement for use in composites on account of its low density, high specific strength, and high hardness. Epoxy is a thermosetting polymer which is used as a resin in natural fibre reinforced composites. Hand lay-up technique was used to fabricate the composites by reinforcing sisal fibres into the epoxy matrix. Composites were prepared with the unidirectional alignment of sisal fibres. Test specimens with different fibre orientations were prepared. The fabricated composites were tested for mechanical properties. Impact test, tensile test, flexural test, hardness test, compression test, and thermal test of composites had been conducted to assess its suitability in industrial applications. Scanning electron microscopy (SEM) test revealed the microstructural information of the fractured surface of composites.

A Study on Electro-optical Characteristics of the UV Aligned FFS Cell on the Organic Layer

  • Han, Jeong-Min;Ok, Chul-Ho;Hwang, Jeoung-Yeon;Kim, Byoung-Yong;Kang, Dong-Hun;Kim, Jong-Hwan;Kim, Young-Hwan;Han, Jin-Woo;Lee, Sang-Keuk;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.135-138
    • /
    • 2007
  • In this study, we investigated the electro-optical (EO) characteristic of fringe-field switching (FFS) mode cell by the two kinds of ultraviolet (UV) alignment method on the organic thin film (polyimide: PI). The suitable organic layers for FFS cell and the aligning capabilities of nematic liquid crystal (NLC) using the in-situ photoalignment method were studied; Disclination is observed after conventional photoalignment method for 1h, and in-situ photoalignment method for 1h. Monodomain alignment of the NLC can be observed via insitu photo alignment method for 2 h and 3 h. It is considered that NLC alignment is due to photo-depolymerization of the polymer with oblique non-polarized UV irradiation on PI surface. An unstable V-T curve of UV-aligned FFS-LCD with conventional photoalignment method can be achieved. However, a stable V-T curve of UV-aligned FFS-LCD with in-situ photoalignment method (1 h), and V-T curve of UV-aligned FFS-LCD with in-situ photo alignment method was much stable comparing with that of other UV-aligned FFSLCD's. As a result, more stable EO performance of UV-aligned FFS-LCD with in-situ photoalignment method for 3h is obtained than that of the other UV-aligned FFS-LCD's.

Influence of a Stacked-CuPc Layer on the Performance of Organic Light-Emitting Diodes

  • Choe Youngson;Park Si Young;Park Dae Won;Kim Wonho
    • Macromolecular Research
    • /
    • v.14 no.1
    • /
    • pp.38-44
    • /
    • 2006
  • Vacuum deposited copper phthalocyanine (CuPc) was placed as a thin interlayer between indium tin oxide (ITO) electrode and a hole transporting layer (HTL) in a multi-layered, organic, light-emitting diode (OLEOs). The well-stacked CuPc layer increased the stability and efficiency of the devices. Thermal annealing after CuPc deposition and magnetic field treatment during CuPc deposition were performed to obtain a stacked-CuPc layer; the former increased the stacking density of the CuPc molecules and the alignment of the CuPc film. Thermal annealing at about 100$^{circ}C$ increased the current flow through the CuPc layer by over 25$\%$. Surface roughness decreased from 4.12 to 3.65 nm and spikes were lowered at the film surface as well. However, magnetic field treatment during deposition was less effective than thermal treatment. Eventually, a higher luminescence at a given voltage was obtained when a thermally-annealed CuPc layer was placed in the present, multi-layered, ITO/CuPc/NPD/Alq3/LiF/AI devices. Thermal annealing at about 100$^{circ}C$ for 3 h produced the most efficient, multi-layered EL devices in the present study.

Fabrication of Micro Patterned Fibronectin for Studying Adhesion and Alignment Behavior of Human Dermal Fibroblasts

  • Lee, Seung-Jae;Son, Young-Sook;Kim, Chun-Ho;Choi, Man-Soo
    • Macromolecular Research
    • /
    • v.15 no.4
    • /
    • pp.348-356
    • /
    • 2007
  • The aim of this study was to fabricate a submicro-and micro-patterned fibronectin coated wafer for a cell culture, which allows the positions and dimensions of the attached cells to be controlled. A replica molding was made into silicon via a photomask in quartz, using E-beam lithography, and then fabricated a polydimethylsiloxane stamp using the designed silicon mold. Hexadecanethiol $[HS(CH_2){_{15}}CH_3]$, adsorbed on the raised plateau of the surface of polydimethylsiloxane stamp, was contact-printed to form self-assembled monolayers (SAMs) of hexadecanethiolate on the surface of an Au-coated glass wafer. In order to form another SAM for control of the surface wafer properties, a hydrophilic hexa (ethylene glycol) terminated alkanethiol $[HS(CH_2){_{11}}(OCH_2CH_2){_6}OH]$ was also synthesized. The structural changes were confirmed using UV and $^1H-NMR$ spectroscopies. A SAM terminated in the hexa(ethylene glycol) groups was subsequently formed on the bare gold remaining on the surface of the Aucoated glass wafer. In order to aid the attachment of cells, fibronectin was adsorbed onto the resulting wafer, with the pattern formed on the gold-coated wafer confirmed using immunofluorescence staining against fibronectin. Fibronectin was adsorbed only onto the SAMs terminated in the methyl groups of the substrate. The hexa (ethylene glycol)-terminated regions resisted the adsorption of protein. Human dermal fibroblasts (P=4), obtained from newborn foreskin, only attached to the fibronectin-coated, methyl-terminated hydrophobic regions of the patterned SAMs. N-HDFs were more actively adhered, and spread in a pattern spacing below $14{\mu}m$, rather than above $17{\mu}m$, could easily migrate on the substrate containing spacing of $10{\mu}m$ or less between the strip lines.

Fabrication of a Parallel Polymer Cantilever to Measure the Contractile Force of Drug-treated Cardiac Cells (약물처리된 심장세포의 세포 수축력 측정을 위한 병렬 폴리머 캔틸레버 제작)

  • Kim, Dong-Su;Lee, Dong-Weon
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.100-104
    • /
    • 2020
  • Thus far, several in vivo biosensing platforms have been proposed to measure the mechanical contractility of cultured cardiomyocytes. However, the low sensitivity and screening rate of the developed sensors severely limit their practical applications. In addition, intensive research and development in cardiovascular disease demand a high-throughput drug-screening platform based on biomimetic engineering. To overcome the drawbacks of the current state-of-the-art methods, we propose a high-throughput drug-screening platform based on 16 functional high-sensitivity well plates. The proposed system simulates the physiological accuracy of the heart function in an in vitro environment. We fabricated 64 cantilevers using highly flexible and optically transparent silicone rubber and placed in 16 independent wells. Nanogrooves were imprinted on the surface of the cantilever to promote cell alignment and maturation. The adverse effects of the cardiovascular drugs on the cultured cardiomyocytes were systematically investigated. The 64 cantilevers demonstrated a highly reliable and reproducible mechanical contractility of the drug-treated cardiomyocytes. Real-time high-throughput screening and simultaneous evaluation of the cardiomyocyte mechanical contractility under multiple drugs verified that the proposed system could be used as an efficient drugtoxicity test platform.