• 제목/요약/키워드: Polyimide surface

검색결과 413건 처리시간 0.024초

고분자 막을 이용한 이온빔 배향 TN-LCD의 전기광학특성 (Electro-optical characteristics of TN-LCD on a Polyimide Surface Exposed to an Ion Beam)

  • 김상훈;황정연;강형구;배유한;이휘원;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.271-272
    • /
    • 2005
  • We studied liquid crystal (LC) alignment with ion beam (IB) on polyimide and electro-optical characteristics of twisted nematic (TN)-liquid crystal display (LCD) on the polyimide surface using obliquely ion beam exposure. A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the polyimide surface was observed. In addition, it can be achieved the good EO properties, and residual DC property of the ion-beam-aligned TN-LCD on polyimide surface.

  • PDF

진공증착중합법에 의해 제조된 폴리이미드 박막의 플라즈마 처리에 의한 표면의 변화 (The Surface Effect of Polyimide Thin Film by Vapor Deposition Polymerization Method With Plasma Treatment)

  • 김형권;이붕주;김종택;김영봉;이덕출
    • 한국전기전자재료학회논문지
    • /
    • 제11권5호
    • /
    • pp.340-346
    • /
    • 1998
  • In this study, we intended to investigate aging effect of polyimide prepared by VDPD(vapor deposition polymerized method). The prepared polymide was treated by the oxygen and argon gas plasma. And we evaluated the polyimide treated by plasma from contact angle, surface leakage current, FT-IR and SEM. We know that the structure of polyimide at surface are changed to amide structure by plasma treating. It seems that strong energy of plasma causes breaking the molecular chin of the polyimide. And surface roughness increases with plasma treating time increased and sequentially the wettability and leakage current increases.

  • PDF

이온주입법에 의한 폴리이미드박막의 표면 개질에 대한 연구 (A Study on the Surface Modification of Polyimide Film by lon Implantation)

  • 김종택;이덕출
    • 한국전기전자재료학회논문지
    • /
    • 제11권4호
    • /
    • pp.293-297
    • /
    • 1998
  • The influence of ion implantation on surface properties of polymers was studied. We investigated microhardness, friction, wear and wettablility of polyimide. Energies of 50, 200keV were used with doses range from $1{\times}10^{13} to 1{\times}10^{16} [ions/cm^2]$. The implanted ion species were B, N and Ar. The microhardness of polyimide was increased after implantation for doses of $1{\times}10^{15}\; [ions/cm^2]$. A reduction of the friction coefficient was in most case correlated with a reduction of wear. The contact angles of water for $B^+,N^+$ implanted polyimide decreased from $76^{\circ}C$ to zero, as the fluencies increased at energies of 50 and 200 KeV. However, the contact angle of Ar ion implanted polyimide did not change under ambient room conditions even if the time elapsed. SEM measurement was performed to characterize the modified surface layer.

  • PDF

폴리이미드 표면을 이용한 플라스틱 STN 셀의 전기 광학 특성 (Electro-Optical Characteristics of Plastic STN Cell on the Polyimide Surface)

  • 김종환;김강우;황정연;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1086-1089
    • /
    • 2003
  • We investigated the electro-optical (EO) performances of the super twisted nematic liquid crystal display (STN-LCD) on the polyimide (PI) surface using polymer film. Monodomain alignment of the plastic STN-LCD can be observed. A stable voltage-transmittance (V-T) curve of the plastic STN-LCD was observed on the polyimide (PI) surfaces using polymer film. Also, a faster response time for the plastic STN-LCD on the polyimide (PI) surfaces using polymer film can be achieved. Therefore, the EO performances of the plastic STN-LCD on the polyimide (PI) surfaces using polymer film is almost the same as that of the glass STN-LCD on a polyimide (PI) surface.

  • PDF

Influence of Surface Treatment of Polyimide Film on Adhesion Enhancement between Polyimide and Metal Films

  • Park, Soo-Jin;Lee, Eun-Jung;Kwon, Soo-Han
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권2호
    • /
    • pp.188-192
    • /
    • 2007
  • In this work, the effects of chemical treatment of polyimide films were studied by FT-IR, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM) and contact angles. The adhesion characteristics of the films were also investigated in the peel strengths of polyimide/aluminum films. The increases of surface functional groups of KOH-treated polyimide films were greatly correlated with the polar component of surface free energy. The peel strength of polyimides to metal substrate was also greatly enhanced by increasing the KOH treatment time, which can be attributed to the formation of polar functional groups on the polyimide surfaces, resulting in enhancement of the work of adhesion between polymer film and metal plate.

펨토초 레이저에 의한 폴리이마이드 가공 특성 (Micromachined Properties of a polyimide by a femtosecond laser)

  • 민철기;이만섭
    • 한국레이저가공학회지
    • /
    • 제11권2호
    • /
    • pp.20-25
    • /
    • 2008
  • Polyimide is one of the useful materials in industry. The surface treatment of polyimide by a femtosecond laser can help accurate and fine fabrication of microstructure. And it can change the transmittance and reflectance of polyimide, too. We put femtosecond laser pulses on polyimide for rectangular or square type surface treaments and observe the change of transmittance and reflectance. Pulsewidth is 172 fs, laser power changes for fabrication are from 5 mW to 20 mW, and transmittance and reflectance are measured under 20m W, 300m W, and 920 mW. Pulse patterning is stable and almost no unwanted surface damage is shown. As power increases, working depth increases but working line width does not increase significantly. As speed changes, they also have same results. It shows the efficiency of a femtosecond laser is good and thermal damage is small for polyimide.

  • PDF

Preparation and Characterization of Surface Energy of BPDA-BAPP Polyimide

  • Kim, Kyung-Hoe;Kim, Yong-Gwon;Kwon, Young-Hwan
    • Macromolecular Research
    • /
    • 제17권6호
    • /
    • pp.388-396
    • /
    • 2009
  • The surface properties (water sorption and repellency, adhesion) are closely related to the surface tension of polymer solids. The critical surface tension (${\gamma}_c$) and surface tension (${\gamma}_s$) of a polymer solid were estimated by the contact angle method by our quantitative imaging system. BPDA (3,3',4,4'-biphenyl tetracarboxylic dianhydride)-BAPP (1,3-Bis(4-aminophenoxy) propane) polyimide was successfully synthesized. The ${\gamma}_c$ values were analyzed by a Zisman plot, a Young-$Dupr\acute{e}$-Good-Girifalco plot, and a log ($1+cos{\theta}$) vs log ${\gamma}_L$ plot. The ${\gamma}_s$ value of BPDA-BAPE polyimide was evaluated using the geometric mean equation and our multiple regression analysis. The calculated values of ${{\gamma}_s^d$ (a dispersion component), ${{\gamma}_s^p$ (a polar component), ${{\gamma}_s^h$ (a hydrogen bonding component), and ${\gamma}_s$ were 30.79, 9.32, 0.20, and 40.31 $mN{\cdot}m^{-1}$, respectively. The ${\gamma}_s$ of BPDA-BAPP polyimide containing both a methylene group and an ether group was larger than that of the polyimide containing only a methylene group.

CF4플라즈마 처리에 의한 잉크젯 프린팅 Ag박막과 폴리이미드 사이의 계면파괴에너지 향상에 관한 연구 (A Study on Improvement of Interfacial Adhesion Energy of Inkjet-printed Ag Thin film on Polyimide by CF4 Plasma Treatment)

  • 박성철;조수환;정현철;정재우;박영배
    • 한국재료학회지
    • /
    • 제17권4호
    • /
    • pp.215-221
    • /
    • 2007
  • The effect of $CF_4$ plasma treatment condition on the interfacial adhesion energy of inkjet printed Ag/polyimide system is evaluated from $180^{\circ}$ peel test by calculating the plastic deformation energy of peeled metal films. Interfacial fracture energy between Ag and as-received polyimide was 5.5 g/mm. $CF_4$ plasma treatment on the polyimide surface enhanced the interfacial fracture energy up to 17.6 g/mm. This is caused by the increase in the surface roughness as well as the change in functional group of the polyimide film due to $CF_4$ plasma treatment on the polyimide surface. Therefore, both the mechanical interlocking effect and the chemical bonding effect are responsible for interfacial adhesion improvement in ink jet printed Ag/polyimide systems.

Sintering and Consolidation of Silver Nanoparticles Printed on Polyimide Substrate Films

  • Yoon, Sang-Hwa;Lee, Jun-Ho;Lee, Pyoung-Chan;Nam, Jae-Do;Jung, Hyun-Chul;Oh, Yong-Soo;Kim, Tae-Sung;Lee, Young-Kwan
    • Macromolecular Research
    • /
    • 제17권8호
    • /
    • pp.568-574
    • /
    • 2009
  • We investigated the sintering and consolidation phenomena of silver nanoparticles under various thermal treatment conditions when they were patterned by a contact printing technique on polyimide substrate films. The sintering of metastable silver nanoparticles commenced at 180 $^{\circ}C$, where the point necks were formed at the contact points of the nanoparticles to reduce the overall surface area and the overall surface energy. As the temperature was increased up to 250 $^{\circ}C$, silver atoms diffused from the grain boundaries at the intersections and continued to deposit on the interior surface of the pores, thereby filling up the remaining space. When the consolidation temperature exceeded 270 $^{\circ}C$, the capillary force between the spherical silver particles and polyimide flat surface induced the permanent deformation of the polyimide films, leaving crater-shaped indentation marks. The bonding force between the patterned silver metal and polyimide substrate was greatly increased by the heat treatment temperature and the mechanical interlocking by the metal particle indentation.

RE 바이어스 스퍼터링한 Cr 박막과 감광성 폴리이미드 사이의 계면 TEM 분석 (TEM Analysis of Interfaces between Cr Film Sputtered with RE Bias and Photosensitive Polyimide)

  • 조성수;김영호
    • 마이크로전자및패키징학회지
    • /
    • 제10권2호
    • /
    • pp.39-47
    • /
    • 2003
  • 감광성 폴리이미드 위에 Cr을 RF 바이어스 스퍼터링 및 RF클리닝 후 DC 스퍼터링한 Cr/폴리이미드의 계면을 TEM으로 관찰하였다. RF power 밀도를 $0.13W/cm^2$에서 $2.12W/cm^2$로 증가시키면서 RF클리닝을 실시한 결과 폴리이미드의 에칭 양상이 둥근 모양에서 뾰족한 모양으로 변하였고 이방성 에칭으로 인해 거칠기가 크게 증가하였다. RF 바이어스 스퍼터링의 경우 RF power를 올리는 동안 RF 클리닝에 의해 폴리이미드가 에칭되었고, 에칭된 부분에 Cr이 증착된 계면을 단면으로 관찰한 결과 Cr과 폴리이미드가 겹쳐져서 혼합된 것처럼 보였다. 그러나 RF power를 올리는 시간을 단축시켜 Cr을 바이어스 스퍼터링했을 때에는 계면이 분명하게 관찰되어 Cr의 implantation이 일어나지 않았음을 알 수 있었다. RF 클리닝한 Cu/Cr/Polyimide를 필 테스트한 결과 짧은 시간의 RF 클리닝으로도 접착력이 크게 증가하였다. 그러므로 RF power를 올리는 동안 실시되었던 RF 클리닝이 RF 바이어스 스퍼터링한 Cr/Polyimide의 접착력 향상에 영향을 주었을 것으로 예상된다.

  • PDF