• Title/Summary/Keyword: Poly styrene

Search Result 355, Processing Time 0.026 seconds

Effects of Compatibilizer on Mechanical, Morphological, and Rheological Properties of Polypropylene/Poly(acrylonitrile-butadiene-styrene) Blends

  • Kum, Chong-K.;Sung, Yu-Taek;Kim, Yong-Su;Lee, Hyung-Gon;Kim, Woo-Nyon;Lee, Heon-Sang;Yoon, Ho-Gyu
    • Macromolecular Research
    • /
    • v.15 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The effects of a compatibilizer on polypropylene (PP)/poly(acrylonitrile-butadiene-styrene) (ABS) blends were studied. Blends of the PP/ABS, with PP-g-SAN copolymer as a compatibilizer, were prepared using a twin screw extruder. The flexural and impact strength of the PP/ABS blends with the PP-g-SAN copolymer increased significantly with PP-rich compositions on the addition of the PP-g-SAN copolymer at 3 phr. The increase in the mechanical properties of the PP/ABS/PP-g-SAN blend may have been due to the toughening effects of the ABS in the PP-rich compositions. In the morphology study of the PP/ABS/PP-g-SAN (80/20) blend with the PP-g-SAN copolymer, the minimum droplet size, $5.1{\mu}m$, was observed with the addition on phr of the PP-g-SAN copolymer. The complex viscosity of the PP/ABS/PP-g-SAN (80/20) blends increased with the addition of3 phr of the PP-g-SAN copolymer. From the above mechanical properties, morphology and complex viscosity results for the PP/ABS blends, it is suggested that the compatibility is more increased with the PP-rich composition (PP:ABS=80/20 wt%) of the PP/ABS blend on the addition of 3 phr of the PP-g-SAN copolymer.

Physical Properties of Foamed Concrete up In the Manufacturing Waste Expanded Poly-Styrene (폐스티로폼의 가공 형태에 따른 기포콘크리트의 물리적 특성 변화)

  • 오세출;서치호;신상태;지석원;김봉주
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.207-215
    • /
    • 2002
  • This study is focusing on mixing the foamed concrete incorporated by waste expanded polystyrene(W-EPS), investigating the physical properties and offering a proper quality control method to the field engineers. Two types of W-EPS (type A and type B) were studied. Type A (B) had globular (crushed) shape and diameter of 3-5 (1-2) mm. The results show that the flow was suddenly reduced with increasing mixing quantity of two types, but it satisfies KS F 4039 until 60 % of mixing rate. In general, the absorption rate was suddenly reduced with increased mixing quantity of two types especially, in type A. Apparent specific gravity was 0.36∼0.53 and reduced with increasing mixing quantify of type A. But it increased in case of type B. Compressive strength and heat conduction rate increased with mixing with W-EPS than non-mixing W-EPS but reduced with mixing too much W-EPS. Based ong the results, it is believed that mixing with W-EPS can improve the recycle of industrial wastes and produce the high quality foamed concrete.

Evaluation of Nuclear Medicine Applications of 3D Printing Phantom - Gamma Camera Centrically (3D 프린팅 팬텀의 핵의학분야 적용 평가 - 감마카메라 중심으로)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose 3D 프린팅 기술은 3D 스캔이나 모델링을 통하여 적측가공 방식으로 제작하는 기공기술로서 금형 없이 직접 생산이 가능하고 빠른 시간 내에 제작이 가능하여 최근 다양한 산업분야에서 본격적으로 적용되고 있다. 3D 프린팅 기술은 의료분야에 있어, 영상의학 및 방사선 치료분야에서 다양하게 활용되고 있지만 핵의학 분야에서는 관련 연구가 미비한 실정이다. 그러므로 본 연구는 기존에 적용되고 있는 핵의학분야 팬텀과 3D 프린팅 기술로 제작된 텀의 특성을 비교하고 적용 가능성을 평가하는데 목적을 두었다. Materials and Methods 방사선 투과도 변화측정 국제기준 팬텀인 알루미늄(Aluminum) 계단 쐐기(step wedge)를 기준($140mm{\times}62mm{\times}35mm$)으로 PMMA(Poly Methyl Meta Acrylate)와 ABS(Acrylonitrile Butadiene Styrene)재질로 각각 동일한 크기의 팬텀을 제작하였다. PMMA 팬텀은 핵의학 분야에서 주로 적용되는 팬텀의 성분과 동일한 소재로 제작하였고, ABS 팬텀 제작은 3D 프린팅 기술의 액체 기반형의 SLA(Stereo Lithography Apparatus)기법을 사용하여 제작하였다. 본 연구는 SPECT/CT장비 BrightView XCT(Philips Health Care, Cleveland, USA)를 이용하였다. 영상 획득은 Rectangular Flood phantom(Biodex, New York, USA) $^{99m}TcO_4$ 3, 6 mCi와 $^{57}Co$ lood phantom(adqual, New Hampshire, USA) $^{57}Co$ 20 mCi를 이용하여 Aluminum, PMMA, ABS 팬텀에 대해 60 min 리스트모드(List mode)로 획득하였다. 획득한 영상의 분석을 위해 관심영역(ROI)을 설정하여 각 팬텀의 단계별로 평가하였다. Results 방사선원의 종류 및 방사선량에 따라 ABS 팬텀의 계수치는 PMMA 팬텀의 계수치와 유사한 값을 나타내며, 두께의 증가에 따라 선형적으로 감소하였다. Aluminum, PMMA, ABS 팬텀의 선감약계수를 비교했을 때, Aluminum 팬텀의 선감약계수는 나머지 두 팬텀보다 수치가 높았고, PMMA, ABS 팬텀에서는 근사치의 선감약계수가 나타났다. Conclusion 3D 프린팅 기술로 제작된 ABS 팬텀을 기준으로 PMMA 팬텀은 두께가 증가함에 따른 계수치의 변화가 유사하게 선형적으로 감소하였고, 선감약계수도 근사치로 나타내었다. ABS 팬텀의 핵의학적 적용 가능성을 확인할 수 있었으며, 추후 연구를 통해 세부적인 교정치(correction value)를 적용한다면 활발한 적용이 가능하리라 사료된다.

  • PDF

Temperature Effect on the Retention Behavior of Sugars in Ion Exchange Chromatography (이온 교환 크로마토그래피에서 온도가 당의 체류 특성에 미치는 영향)

  • Kim, Jin-Il;Lee, Chong-Ho;Koo, Yoon-Mo
    • Korean Chemical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.722-727
    • /
    • 2005
  • Dow99Ca350 (Dowex monosphere 99Ca/350 separation resin), MFG-220, and Finex CS-10GC are ion-exchange resins, and primarily used to separate sugars, and all of these resins have poly styrene DVB backbone, and sulfonyl group. These resins are already used to separate sugars continuously at sugar industry at constant temperature. These resins are used in experiments for understanding temperature effect on retention or adsorption behavior. Using Dow99Ca350, swelling test, porosity test, pulse test, and frontal analysis at various temperatures were performed. In the cases of MFG-220, and Finex CS-10GC, the effect of temperature variation was verified by pulse test. The experimental results are shown that Dow99Ca350, MFG-220, and Finex CS-10GC, which are commercial resins for sugar separation, are stable to temperature variation because the maximum change of retention time of fructose, and glucose are 1.76, and 3.37% respectively.

Development of Schiff Base Column and Glow Discharge Detector for HPLC : Preliminary Study I (HPLC용 Schiff Base 컬럼과 Glow Discharge 검출기의 개발에 관한 기초연구 I)

  • Kang, Mi-Ra;Kim, Eun-Soo;Shin, Jung-Sook;Park, Hyun-Kook;Yang, Jung-Sung;Lee, Sang C.
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.265-272
    • /
    • 1995
  • Schiff base ligand columns and glow discharge detector have been developed for the trace analysis of metal ions desolved in water. Various types of hydrazide Schiff base ligands have been used and, additionally, they were examined as a filling material of a HPLC column. The hydrazide Schiff base ligands used were N, N'-oxalybis(salicylaldehydrazone) (OBSH), N, N'-malonylbis(salicylaldehydrazone) (MBSH), and N, N'-succinylbis(salicylaldehydrazone) (SBSH). A mixture of Schiff base ligand and poly(styrene divinylbenzene) was examined and it showed a smooth flow of solution. The OBSH-polymer column demonstrated different effluent factors for different metal ions. Metal ions in eluates were detected by Hollow Cathode Glow Discharge-Atomic Emission Spectrometry(HCGD-AES). HCGD-AES showed good sensitivity and selectivity. This is only the preliminary results of new OBSH-polymer column and glow discharge detector.

  • PDF

Preparation and Performance of Low Pressure PVDF Nano-composite Hollow Fiber Membrane Using Hydrophilic Polymer (친수화 고분자 소재를 이용한 저압용 PVDF 나노복합중공사막의 제조 및 성능 연구)

  • Park, Cheol Oh;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.28 no.5
    • /
    • pp.361-367
    • /
    • 2018
  • In this study, the nanofiltration (NF) composite membranes for the low pressure use were prepared using polyvinylidene fluoride (PVDF) hollow fiber membrane as a supporter. Poly styrene sulfonic acid (PSSA) and polyethyleneimine (PEI) were coated onto the PVDF membrane by both layer-by-layer and salting-out methods. To characterize the prepared NF membranes in terms of the flux and salt rejection, 100 mg/L feed solutions of NaCl, $MgCl_2$, and $CaSO_4$ were used at the flow rate of 1 L/min and the operating pressure of 2 bar at room temperature. The NF membranes coated with 20,000 ppm PSSA (ionic strength 1.0) solution for 3 minutes and then 30,000 ppm (ionic strength 0.1) solution for 1 minute were observed the best performance. The permeability and salt rejection were 38.5 LMH, 57.1% for NaCl, 37.9 LMH and 90.2% for $MgCl_2$ and 32.4 LMH and 54.6% for $CaSO_4$, respectively.

Determination of Boron by Ion Pair Liquid Chromatography with Chromotropic Acid (Chromotropic Acid를 착화제로 이용한 이온쌍 액체 크로마토그래피에 의한 붕소의 분리와 정량)

  • Yun, Young Ja;Yu, Gu Yong
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.288-293
    • /
    • 1995
  • The separation and determination of boron with chromotropic acid (1,8-Dihydroxynaphthalene-3,6-disulfonic acid) as a complex agent has been studied using ion pair liquid chromatography. The use of tetrabutylammonium bromide added as an ion pair reagent to mobile phase (MeOH 61%, phosphate buffer 39% pH=8.5) allowed good separation of boron-chromotrophic acid complex anion and chromotrophic acid on poly(styrene-divinylbenzene) based reversed phase column (PRP-1, 15 $cm{\times}4.6$ mm i.d.). The complex formation between boric acid and chromotrophic acid was enhanced in the presence of 0.1 M tetrabutylammonium bromide, resulting in high sensitivity. The linear calibration was achieved over the boron concentration range of 0.5∼1000 ${\mu}g/L.$ The detection limit was 0.5 ${\mu}g/L$ (S/N=2). The proposed method was applied to the determination of boron in commercially available chemicals, $Na_2SO_4$, NaOH, KCl.

  • PDF

The Development of Analysis System for Genes Related Disease Using Chemical Properties of DHPLC (DHPLC의 화학적 특성을 이용한 질병 유전자의 분석 시스템 개발)

  • Kim, Jong-Gyu;Nam, Yun-Hyeong;Park, Sang-Beom;Lee, Jae-Sik;Gang, Won
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.2
    • /
    • pp.116-122
    • /
    • 2006
  • In this study we extracted DNA from 100 tissues of breast cancer patients and 103 normals. Then we confirmed single-nucleotide polymorphism(SNP) using PCR-DHPLC(polymerase chain reaction-denaturing high performance liquid chromatogrphy).Also, we studied SNP of samples using several columns to identify relation between packing materials of column and resolution.As a result, we identified 4 C/A, C/G genotypes(4%) in exon 5 and 37 T del genotypes(37%) in exon 8 among 100 breast cancer tissues and 2 in exon 5, 9 in exon 8 among 103 normal samples.In resolution test, we confirmed that PS-DVB(poly styrene-divinylbenzen) column is more efficient than C18 column.

Effect of Adding Crosslinked Particles on Rheological and Electrical Properties of Polystyrene/Carbon Nanotube Nanocomposites (가교 입자 첨가가 폴리스티렌/탄소나노튜브 나노복합재료의 유변물성 및 전기적 물성에 미치는 영향)

  • Yeom, Hyo Yeol;Na, Hyo Yeol;Lee, Seong Jae
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.767-773
    • /
    • 2014
  • Rheological and electrical properties of polystyrene (PS)/carbon nanotube (CNT) nanocomposites via coagulated precipitation were investigated. Chemical modification and surfactant wrapping of CNT to improve the dispersion of CNTs may reduce the intrinsic properties of pristine CNT. To avoid this problem, PS and CNTs were dissolved and dispersed in dimethylformamide and then PS/CNT nanocomposites were prepared by the coagulated precipitation of CNT-dispersed PS solution in water. The coagulated precipitation method was highly effective enhancing the electrical conductivity of nanocomposites. Furthermore, the effect of adding poly(styrene-co-divinylbenzene) crosslinked particles to PS matrix on the rheological and electrical properties was investigated. With the addition of the crosslinked particles, the electrical percolation threshold of CNT reduced to 0.25 wt% and electrical conductivity increased further. It is speculated that CNTs in the volume occupied by crosslinked particles helped electrical pathway formation.

Silsesquioxane/Polystyrene Hybrid Materials via Charge Transfer Interactions (전하 이동을 이용한 실세스퀴옥산/폴리스티렌 하이브리드)

  • Choi, Ji-Won;Chujo, Yoshiki
    • Polymer(Korea)
    • /
    • v.31 no.2
    • /
    • pp.136-140
    • /
    • 2007
  • Charge transfer interaction as a hybridization mechanism of silsesquioxane/polymer was tested using carbazole (electron donor) group and dinitrobenzene (electron acceptor) group. Hybridization test was conducted using films made from mixing/casting of poly (carbazole-styrene) (PS/D) and dimtrobenzyl silsesquioxane (Cube/A), and transparent hybrid films were successfully obtained under some conditions. $^1H-NMR$ of PS/D and Cube/A, and W absorption test of hybrid films showed that one acceptor and one donor can form one charge transfer complex when no silsesquioxane molecule was included in films, but transparent hybrids with no phase separation were obtained only at acceptor/donor ratios less than 0.7 : 1. These results also suggested that on average 4 charge transfer complexes form per one silsesquioxane.