• Title/Summary/Keyword: Polishing time

Search Result 303, Processing Time 0.031 seconds

Analgesic Effect of Combination of Ketamine Hcl/Propionyl promazine HCI and Tiletamine HC1/Zolazepam HCl for Scaling in Dog (개의 치석제거를 위한 마취에 있어 Ketamine HCl/Propionyl promazine HCI과 Tiletamine HCl/Zolazepam HCl의 투여효과)

  • Shin Nam-Sik;Choi Youn-Ju;Kwon Soo-Wahn;Han Duk-hwan;Park Hyun-Jong;Kweon Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.10 no.2
    • /
    • pp.221-226
    • /
    • 1993
  • To study effective dossage and administration route for scaling, ketamine HCl/propionyl promazine HCl(ketamine) combination and tiletamine HCl/zolazepam HCl(zoletil) were administered in one hundred six dogs. The dogs were toy poodle, Yorkshire Terrier, Pekingese and Chihuahua. Scaling and polishing time, possible treatment time after the first injection of anesthetics, the number of anethesia added, presence of tongue movement during anesthesia, the presence of swaying sign during recovery and respiration were evaluated. The possible treatment time after the first Injection of anesthetic in toy poodle were 26.3${\pm}$3.0 minutes with intravenous(IM) treatment of ketamine 10mg/kg, and 21.4${\pm}$6.6 minutes with intramuscula(IM) treatment of zoletil 8mg/kg, In Yorkshire Terrier were 19.51: 1.7 minutes with IV treatment of ketamine 10mg/kg. 19.0${\pm}$5.2 minutes IM and 20.8${\pm}$6.1 minutes with IM treatment of zoletil 5mg/kg,24.8${\pm}$3,5 minutes with IM treatment of zoletil 8mg/kg. In pekingese were 27.5${\pm}$2.1 minutes with IM treatment of ketamine 10mg/kg,28.0${\pm}$4.2 minutes with IM treatment of zoletil 8mg/kg. In Chihuahua were 19.5${\pm}$1.9 minutes with IV treatment of ketamine 7mg/kg, 17.5${\pm}$1.7 minutes with IM treatment of ketamine 10mg/kg and 20.3${\pm}$3.8 minutes with IM treatment of zoletil 5mg/kg, 21.2${\pm}$5.5 minutes with IM treatment of zoletil 8mg/kg. Swaying sign was observed in all group during recovery time, espically, in toy poodle and Yorkshire Terrier which administered zoletil 8mg/kg IM showed more severe swaying sign. The present results suggested that injection of zoletil 8mg/kg IM might be relatively effective for scaling in Chihuahua Within 20 minutes treatment for scaling in Yorkshire Terrier and Chihuahua, IM treatment of ketamine 7 to 10mg/kg is recommended.

  • PDF

The effect of tooth brushing and thermal cycling on a luster change of ceromers finished with different methods

  • Cho, Lee-Ra;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.336-347
    • /
    • 2000
  • Statement of problem. Luster loss in esthetic anterior ceromer restoration can occur and can be related with rough surface texture. Understanding durability of surface finishing methods like polishing and surface coating have critical importance. Purpose. This study evaluated the effect of tooth brushing and thermal cycling on surface luster of 3 ceromer systems (Artglass, Targis, Sculpture) treated with different surface finishing methods. Material and methods. Seventy-two samples were prepared: 12 for control group Z100, 12 for Artglass, 24 for Targis, and 24 for Sculpture. Half of the Targis and Sculpture were polished according to the manufacturer's recommendation. The rest of the samples were coated with staining and glazing solution for Targis and Sculpture, respectively. All specimens were subjected to 10,000 cycles between $5^{\circ}C\;and\;55^{\circ}C$ with 30 seconds dwell time. Tooth brushing abrasion tests were performed in a customized tooth brushing machine with 500g back and forth for 20,000 cycle. Luster comparisons were based on grading after direct observation, and light reflection area was measured with Image analysis software. Results. All materials showed an decrease in luster grade after thermal cycling and tooth brushing. The post-tooth brushing results revealed that the glazed Sculpture had greater mean luster grade than did any other groups. While, the stained Targis group showed greatest changes after tooth brushing (p < 0.05), polished Targis and Sculpture did not show significant changes. However, glazed Sculpture showed discretely fallen out glaze resin. Conclusion. From the results of this study, all of the ceromer specimens were much glossy than control composite group after tooth brushing. coatings used for Targis and Sculpture had not durability for long term use.

  • PDF

Effect of different grinding burs on the physical properties of zirconia

  • Lee, Kyung-Rok;Choe, Han-Cheol;Heo, Yu-Ri;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.137-143
    • /
    • 2016
  • PURPOSE. Grinding with less stress on 3Y-TZP through proper selection of methods and instruments can lead to a long-term success of prosthesis. The purpose of this study was to compare the phase transformation and physical properties after zirconia surface grinding with 3 different grinding burs. MATERIALS AND METHODS. Forty disc-shaped zirconia specimens were fabricated. Each Ten specimens were ground with AllCeramic SuperMax (NTI, Kahla, Germany), Dura-Green DIA (Shofu Inc., Kyoto, Japan), and Dura-Green (Shofu Inc., Kyoto, Japan). Ten specimens were not ground and used as a control group. After the specimen grinding, XRD analysis, surface roughness test, FE-SEM imaging, and biaxial flexural strength test were performed. RESULTS. After surface grinding, small amount of monoclinic phase in all experimental groups was observed. The phase change was higher in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs. The roughness of surfaces increased in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs than control groups and ground with Dura-Green. All experimental groups showed lower flexural strength than control group, but there was no statistically significant difference between control group and ground with Dura-Green DIA and AllCeramic SuperMax burs. The specimens, which were ground with Dura-Green showed the lowest strength. CONCLUSION. The use of dedicated zirconia-specific grinding burs such as Dura-Green DIA and AllCeramic SuperMax burs decreases the grinding time and did not significantly affect the flexural strength of zirconia, and therefore, they may be recommended. However, a fine polishing process should be accompanied to reduce the surface roughness after grinding.

Impact of Media Type and Various Operating Parameters on Nitrification in Polishing Biological Aerated Filters

  • Ha, Jeong-Hyub;Ong, Say-Kee;Surampalli, R.
    • Environmental Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.79-84
    • /
    • 2010
  • Three biological aerated filters (BAFs) composed of a PVC pipe with a diameter of 75 mm were constructed and operated at a waste-water temperature at $13^{\circ}C$. The media used for each BAF were: 5-mm gravel; 5-mm lava rock; 12.5-mm diameter by 15-mm long plastic rings, all with a media depth of 1.7 m. The feedwater, which simulated the effluent of aerated lagoons, had influent soluble chemical oxygen demand (sCOD) and ammonia concentrations of approximately 50 and 25 mg/L, respectively. For a hydraulic retention time (HRT) of two hours without recirculation, ammonia percent removals were 98.5, 98.9, and 97.8%, for the gravel, lava rock, and plastic rings, respectively. By increasing the effluent recirculation from 100 to 200% for an HRT of one hour, respective ammonia removals improved from 90.1 to 96, 76.5 to 90, and 65.3 to 79.5% for gravel, lava rock, and plastic rings. Based on the ammonia and sCOD loadings for different HRTs, the estimated maximum ammonia loading was approximately 0.6 kg $NH_3-N/m^3$-day for the three BAFs of different media types. The zero-order biotransformation rates for the BAF with gravel were found to be higher than the lava rock and plastic ring media. The results ultimately showed that BAF can be used as an add-on system to aerated lagoons or as a secondary treatment unit to meet ammonia discharge limits.

Reel-to-reel electropolishing of Ni alloy tapes for IBAD template (IBAD template용 니켈 합금의 연속 전해연마)

  • Ha H. S;Kim H. K;Ko R. K;Kim H. S;Song K. J;Park C;Yoo S. I;Joo J. H;Moon S. H
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.69-73
    • /
    • 2004
  • Ni alloy tape is electropolished to be used as a metal substrate for fabrication of IBAD (ion-Beam Assisted Deposition)-MgO texture template fur HTS coated conductor. Electropolishing is needed to obtain a very smooth surface of Ni alloy tape because the in-plane texture of templates is sensitive to the roughness of metal substrate. The critical current of YBCO coated conductor depends on the texture of YBCO that depends on the texture of the IBAD MgO layer. And so the smoothness of the metal substrate is directly related to the superconducting properties of the coated conductor. In this study, we have prepared a reel-to-reel electropolishing apparatus to polish the Ni alloy tapes for IBAD. Various electropolishing conditions were investigated to improve the surface roughness. Hastelloy tape is continuously electropolished with high polishing current density (0.5 ∼ 2 A/$\textrm{cm}^2$) and fast processing time (1 ∼ 3 min). Polished hastelloy tapes have surface roughness(RMS) of below 1 nm on a 5 ${\times}$ 5 $\mu\m^2$ from AFM and SEM.

  • PDF

Performance Evaluation of Tertiary Post-denitrification Processes for the Reuse of Secondary Effluent from Wastewater Treatment Plant (하수2차처리수의 재이용을 위한 후탈질공정의 평가)

  • Lee, Chanho;Yun, Zuwhan;Yi, Yun Seok;Lee, Han Saem;Ahn, Dong Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.642-649
    • /
    • 2007
  • The effectiveness of add-on tertiary treatment processes for the polishing of the effluent of a biological nutrient removal (BNR) system from a modified $A^2/O$ process has been examined under the field condition with pilot-scale plants. The add-on treatment processes of 1) combined biofilm anoxic reactor and sand filtration, and 2) two-stage denitrification filter had been operated with various operating conditions. The experimental results indicated that two-stage denitrification filter could produced a better polished tertiary effluent. Filtration rate of $150m^3/m^2{\cdot}d$ for the 2-stage denitrifying filter could decrease the nitrate removal probably due to shorter detention time that caused insufficient reaction for denitrification. Two stage denitrification filter operated with M/N ratio of 3.0 and filtration rate of $100m^3/m^2{\cdot}d$ produced the tertiary effluent with nitrate and SS concentraitons of 2.8 mg/L and 2.3 mg/L, respectively. When the operating temperature reduced $30^{\circ}C$ to $18^{\circ}C$, $NO_3{^-}-N$ removal efficiency decreased from 73% to 68%.

Study of Inhibition Characteristics of Slurry Additives in Copper CMP using Force Spectroscopy

  • Lee, Hyo-Sang;Philipossian Ara;Babu Suryadevara V.;Patri Udaya B.;Hong, Young-Ki;Economikos Laertis;Goldstein Michael
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.5-10
    • /
    • 2007
  • Using a reference slurry, ammonium dodecyl sulfate (ADS), an anionic and environmentally friendly surfactant, was investigated as an alternative to BTA for its inhibition and lubrication characteristics. Results demonstrated that the inhibition efficiency of ADS was superior to that of BTA. Coefficient of friction (COF) was the lowest when the slurry contained ADS. This suggested that adsorbed ADS on the surface provided lubricating action thereby reducing the wear between the contacting surfaces. Temperature results were consistent with the COF and removal rate data. ADS showed the lowest temperature rise again confirming the softening effect of the adsorbed surfactant layer and less energy dissipation due to friction. Spectral analysis of shear force showed that increasing the pad-wafer sliding velocity at constant wafer pressure shifted the high frequency spectral peaks to lower frequencies while increasing the variance of the frictional force. Addition of ADS reduced the fluctuating component of the shear force and the extent of the pre-existing stick-slip phenomena caused by the kinematics of the process and collision event between pad asperities with the wafer. By contrast, in the case of BTA, there were no such observed benefits but instead undesirable effects were seen at some polishing conditions. This work underscored the importance of real-time force spectroscopy in elucidating the adsorption, lubrication and inhibition of additives in slurries in CMP.

Differences in view of dental hygienist and patient's scaling actual condition and disputes (치과위생사와 환자의 치석제거 실태와 분쟁에 대한 견해 차이)

  • Seong, Mi-Gyung;Kang, Hyun-Kyung;Kim, Yu-Rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.5
    • /
    • pp.623-633
    • /
    • 2020
  • Objectives: Since scaling has been covered by insurance, the number of patients undergoing scaling has increased. Simultaneously, legal disputes around scaling have increased. Therefore, this study was aimed at comparing the differences between the perceptions of dental hygienists and patients regarding the scaling procedure and providing dental hygienists with basic data to find ways to reduce disputes arising from these differences. Methods: A survey was conducted on 119 dental hygienists working in Busan and the South Gyeongsang Province and 110 patients who visited hospitals for scaling. Frequency analyses were performed for dental hygienists' scaling behavior and patient discomfort during scaling. The independent t-test and chi-square test were performed to compare the perceptions of dental hygienists and patients regarding the scaling procedure. Results: Polishing after scaling was performed according to 70.1% of dental hygienists but only 29.9% of patients. Oral health education was provided according to 20.4% of dental hygienists, while 79.6% of patients said that they received oral health education at the Dentiform. The scaling time was reported to be shorter by patients than by dental hygienists. Both dental hygienists and patients said that legal action was required if problems occurred during scaling, and the refund standard was that patients needed it more than dental hygienists. Conclusions: There are differences between the perceptions of dental hygienists and patients regarding scaling. Dental hygienists should identify these differences and try to prevent conflicts or disputes with patients around scaling.

A Study on Predicting Ship Resistance Performance due to Surface Roughness Using CFD (CFD를 이용한 표면 거칠기에 따른 선박의 저항 성능 추정에 관한 연구)

  • Seok, Jun;Park, Jong-Chun;Shin, Myung-Soo;Kim, Sung-Yong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.5
    • /
    • pp.400-409
    • /
    • 2016
  • In recent, shipping companies have made an enormous effort to improve the operation of vessel in various approaches, due to recession of shipping market and increasing competition among shipping companies. One of important parameters for improving the efficiency of vessel is the resistance performance that consist of friction and residual resistance. Especially, it is recognized that the friction resistance tends to be affected by conditions of vessel’s surface and occupies approximately 70~90% of the total resistance for slow speed ships. In general, the surface of vessel is covered with various type of paint to reduce fouling and corrosion. As time goes by, however, it is so hull roughness would be increased by fouling over the wetted surface that anti-fouling paints, such as CDP(Controlled Depletion Paint), Tin-Free SPC(Self Polishing Co-polymer) or Foul Release, are applied evenly on the hull surface. Nevertheless, these anti-fouling paints could not prevent fouling absolutely. A fundamental study on evaluating ship resistance performance variation due to hull roughness has been performed using a commercial software, Star-CCM+, which solves the continuity and Navier-Stokes equations for incompressible and viscous flow. The results of present simulation for plate are compared with some experimental data available and the effect of surface roughness to ship resistance performance is discussed.

A STUDY ON MARGINAL ADAPTATION OF READY-MADE STAINLESS STEEL CROWN TO THE PRIMARY MOLAR (기성금관수복 유구치의 변연 적합도에 관한 연구)

  • Lee, Sun-Kyung;Lee, Gwang-Su;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.389-400
    • /
    • 1996
  • In Class II amalgam restoration in deciduous molar, failure rate and incidence of recurrent caries are high as children become older. In order to preserve deciduous molars till the physiologic exfoliation time, stainless steel crown is a choice of the treatment. As a result of a careless treatment, such as overhanging margin, poor marginal adaptation, poor proximal contour and inadequate mesiodistal width give rise to interfering eruption of the adjacent teeth, recurrent caries and chronic gingival irritation and insufficient arch length respectively. In this study, 252 s.s. crowned teeth extracted due to physiologic exfoliation or periapical lesion. The purpose of this study is to analyze the marginal adaptation of stainless steel crown to the deciduous molar in order to obtain better clinical result. The results were as follows : 1. Between the length of s.s. crown and the marginal gap of crown, positive correlations were shown. 2. Largest amount of marginal gap was shown at buccal side in upper deciduous molars and lower first deciduous molar, lingual side in lower second deciduous molar. But no significant diffrence were found statistically compared to second most largest one. 3. Incidence of exposed restoration and recurrent caries were higher in proximal surface than buccal/lingual surface. And extension of restoration below the margin of s.s. crown gives rise to higher rate of recurrent caries. 4. Defect of contour was found in 34%, frequently found in lower 1st deciduous molar and upper 1st deciduous molar. 5. Marginal polishing defects were found in 23%. 6. Ledge was formed in 10% especially in lower 1st deciduous molar and lower 2nd deciduous molar. 7. 16% of the teeth had wear facet due to traumatic occlusion, 7% of them had occlusal perforation.

  • PDF